Concoa 547 Series Скачать руководство пользователя страница 3

3

USER RESPONSIBLITY

INTENDED USE OF PRODUCT

CUSTOMER ASSISTANCE

The 316L stainless steel switchover system (547 series) is intended for use in non-oxidizing, non-corrosive, 

non-toxic gas applications (Not for use in O

2

).  Please note the safety information shown in the later sections. 

System is designed to operate at flows less than 4000 SCFH.

This equipment will perform in conformity with the description contained in this manual and accompanying 

labels and/or inserts when installed, operated, maintained,  and repaired in accordance with the instructions 

provided. This equipment must be checked periodically. Improperly working equipment  should not be used. 

Parts that are broken, missing, worn, distorted or contaminated, should be replaced immediately.  CONCOA 

recommends that a telephone or written request for service advice be made to  CONCOA Customer Service in 

Virginia Beach, Virginia.  PHONE:  1-800-225-0473, FAX: 1-757-422-3125, or E-MAIL: [email protected].

This equipment or any of its parts should not be altered without prior written approval by CONCOA. The user 

of this equipment shall have the sole responsibility for any malfunction that results from improper use, faulty 

mainte- nance, damage, improper repair, or alteration by anyone other than CONCOA or a service facility 

designated by CONCOA.

In the event of equipment failure, call CONCOA Customer Service.  Please be prepared to provide the model 

number and serial number of the equipment involved, in addition to some details regarding its application. 

This would include inlet and outlet pressures, flow rate, environmental conditions, and gas service.

Things to consider before removing the system from the box….

1.   Know the properties and special handling requirements of the gas being used.  Many specialty gases are 

quite dangerous (flammable, asphixiant, etc.).  Equipment failure or misuse may lead to problems such as a 

release of gas through the regulator cartridge.  Proper safety measures should be established to handle these 

and other component failures.

2.   Be sure that the assembly purchased is suitable for the gas and type of service intended. The regulator 

label provides the following information:

 

a. Model number 

 

b. Serial number

 

c. Maximum inlet pressure

Be sure that the equipment received conforms to the order specifications. The user is responsible for select-

ing equipment compatible with the gas in use, and conditions of pressure, temperature, flow, etc. Selection 

information can be found in CONCOA’s  Pressure and Flow Control Specialty Gas Catalog or online at www.

concoa.com. In addition, CONCOA representatives are trained to aid in the selection process.

3.   Inspect the assembly upon receipt to be sure that there is no damage or contamination. Pay particular 

attention to connecting threads.  While CONCOA assembles system components to exacting leak- tight 

standards, the customer should also inspect for any loosening of parts that may occur in shipping or instal-

lation. Loose parts may be dangerously propelled from an assembly. If there are adverse signs (leakage or 

other malfunction), return the assembly to the supplier.  While it is advised that soiled regulators be returned 

for cleaning, simple external dust or grease may be removed by a clean cloth and if required with aqueous 

detergent suitable for the application. If there are signs of internal contamination, return to the supplier.

Содержание 547 Series

Страница 1: ...nd Comply with These Instructions Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com February 2016 A...

Страница 2: ...um inlet only With 547 XXX4 models an optional universal voltage remote alarm provides an audible and visual warning that a changeover is about to occur Pressing a button on the front of the remote al...

Страница 3: ...conditions and gas service Things to consider before removing the system from the box 1 Know the properties and special handling requirements of the gas being used Many specialty gases are quite dange...

Страница 4: ...lways rotate the priority valve 180 so that the arrow on the knob is pointing to the in use full side of the switchover CAUTION Always close all manifold station and cylinder valves on the nearly empt...

Страница 5: ...the cylinder decreases Manifolds installed in open locations should be protected from weather conditions During winter protect the manifold from ice and snow In summer shade the manifold and cylinders...

Страница 6: ...ad as shown in Figure 3 make sure the tape does not overlap the end of the fitting As the tape is wrapped in the direction of the thread spiral pull tightly on the end of tape so that the tape conform...

Страница 7: ...to avoid squashing the gasket into the gas line Keep extra gaskets on hand c Never use oil or grease on regulator or cylinder fittings as it may contaminate pure gases or create a fire hazard Installi...

Страница 8: ...X 547 3XXX 547 4XXX Cylinder Pressure 250 350 PSIG 17 24 BAR 1050 1150 PSIG 72 79 BAR 1250 1500 PSIG 86 103 BAR 1800 2300 PSIG 124 159 BAR 2800 3300 PSIG 193 228 BAR 3800 4300 PSIG 262 297 BAR higher...

Страница 9: ...ght side switching pressures MAINTENANCE On regular intervals the system should be checked for leaks and proper function see trouble shooting Any leaks in the system should be corrected immediately Th...

Страница 10: ...OA Do the following before shipping 1 Adequately package the system If possible package in the original shipping container 2 Ship prepaid 3 Include a statement of the observed deficiency 4 Indicate th...

Страница 11: ...obligation and Buyer s sole and exclusive remedy under the above warranties is limited to repairing using new or reconditioned parts or replacing free of charge except for labor if permanently install...