![Concoa 529 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/concoa/529-series/529-series_installation-and-operating-instructions-manual_2651331009.webp)
9
TROUBLESHOOTING
Symptom
Cause
Unit is plugged in but no lights are lighting on the
Alarm
1. Check to see that there is power at the source.
2. Check that cable to Protocol Station is plugged
in.
3. If the Alarm has been re-configured from the
factory settings, check that the DIP switches
were properly set. Refer to "Configuring the
Remote Alarm" section of the manual.
Unit is plugged in, red alarm light(s) are ON but
the gauge on the Protocol Station is above the alarm
pressure.
1. Check to see that the cable running between the
alarm and the Protocol Station is properly wired.
Audible Alarm begins to sound as soon as power is
turned ON.
1. Check that the Protocol Station Connector is
plugged in properly.
2. Check that the cable between the Protocol
Station and Alarm is not cut or pinched
somewhere.
3. Check to see that all the wires in the cable are
properly soldered to the connectors.
Output does not appear to be functioning.
1. Check the cable to the output device to be sure
it is properly connected.
2. Check the Output Connector to be sure it is
properly plugged into the Alarm.
3. Check the external output device to make sure it
is functioning properly.
SERVICE
Service by a factory authorized facility should be done if an Alarm becomes inoperative and troubleshooting has
not isolated the problem. Contact CONCOA Customer Service at 1-800-225-0473 for assistance.
If advised to return the unit for service you should:
1. Package the Alarm to prevent damage in shipping. If possible, use the original shipping materials.
2. Ship the unit back pre-paid.
3. Make sure the RMA number appears on the packaging and inside the package.
4. Include an explanation of the problem you encountered.
Содержание 529 Series