OPTION 1 (continued)

Using the pin assignments shown in Table 1 and the connector view in Figure 3, solder the wires to the 
appropriate pins.  After soldering is complete attache the cable cover, cable retainer, and locking nut to 
each of the circular connector plugs.

Plug the one side of the cable into the Remote Alarm and secure it by turning the locking nut until it 
locks.  Plug the other circular connector into the Protocol Station securing it by turning the locking 
nut until it locks.

OPTION 2:  For Protocol Stations that have a 4 pin circular connector.

It will be necessary to obtain a 4 conductor cable.  The length of the cable is determined by the application 
but should be limited to no longer than 1500 feet.  It is recommended that 22 AWG stranded wire be 
used.  (Alpha #5004C is an acceptable type.)

Cut the 4 conductor cable to length.  Remove the outer jacket of the cable to expose approximately 11⁄4 
inches of the internal conductors.  Strip away 1⁄4 inch of the insulation on each of the 4 conductors.  Tin 
the leads of the conductors.  Slide the protective cover, cable retainer, and locking nut for the circular 
connector over one end of the cable as shown in Figure 4. 

SYSTEM

Protocol Station 

Pin #

Remote Alarm 

Connector Pin #

Function

RIGHT BANK

2

4

RBSW status

---

---

alarm

1

3

+12

4

6

Gnd

Table 2

notch

notch

Figure 5 - View A-A

Figure 6 - View A-A

Figure 4

Cable Retainer Tabs

Cable Cover

Cable Retainer

Locking Nut

Plug

Connector pins (Figures 3 and 4) 

viewed from this side

Содержание 529 Series

Страница 1: ...Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Ju...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...to the connectors prior to plugging the connectors into the Alarm For connector pin assignments please refer to the CONNECTING THE ALARM section of this manual GENERAL SAFETY PRACTICES Basic safety pr...

Страница 4: ...ntrols one 1 set of relay contacts that are brought to the Output Connector so they may be used to control an external device When a system is operating normally the status indicator light will be gre...

Страница 5: ...a 6 conductor cable The length of the cable is determined by the application but should be limited to no longer than 1500 feet It is recommended that 22 AWG stranded wire be used Alpha 5006C is an acc...

Страница 6: ...is determined by the application but should be limited to no longer than 1500 feet It is recommended that 22 AWG stranded wire be used Alpha 5004C is an acceptable type Cut the 4 conductor cable to le...

Страница 7: ...activates a set of relay contacts in response to an alarm condition This set of relay contacts can be connected to any external device that is activated by the opening or closing of a switch Examples...

Страница 8: ...ng steps 1 Unplug the power plug from the Remote Alarm power jack 2 It is best to set the unit on a flat surface face down Remove the four 4 screws that hold the back cover on and set the cover aside...

Страница 9: ...rotocol Station and Alarm is not cut or pinched somewhere 3 Check to see that all the wires in the cable are properly soldered to the connectors Output does not appear to be functioning 1 Check the ca...

Страница 10: ...lcro Mounting Strips MOUNTING DETAIL ELECTRICAL SPECIFICATIONS Protocol Station Remote Alarm 120 Volt Version 120 Volts A10 50 60 hz 6VA 220 Volt Version 220 Volts A10 50 60 hz 6VA Fuses Internal Rese...

Страница 11: ...nyone other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OFAMERICA s sole and exclusive obligation and Buyer s...

Страница 12: ...5 www concoa com Qty Part Number Description 1 5295135 01 120 ASSY 120VAC PROTOCOL STATION REMOTE ALARM 1 5295135 01 220 ASSY 220VAC PROTOCOL STATION REMOTE ALARM INCLUDES 1 5295135 PROTOCOL STATION R...

Отзывы: