PART NUMBERS

529 5135-01-120 

Protocol Station Remote Alarm  120 VAC version

529 5135-01-220 

Protocol Station Remote Alarm  220 VAC version

USER RESPONSIBILITY

Service to this product should only be performed by CONCOA or an authorized CONCOA agent.  Requests for 
service may be made through CONCOA CUSTOMER SERVICE at 1-800-225-0473.  Written requests may 
be made using CONCOA’s FAX number at 1-757-422-3125 or CONCOA’s E-MAIL at [email protected].

CONCOA accepts no responsibility for damage or injury if this product is modified in any way.

CONCOA assumes/accepts no liability or responsibility for damage to individuals or equipment that may occur 
when using this product.

INTENDED USE OF PRODUCT

The Protocol Station Remote Alarm is used to monitor and report the status of inlet pressure on Protocol Stations.   
The Alarm can be configured to operate with either normally open or normally closed pressure switch contacts.  
The Alarm contains a set of relay contacts  that can be used to control any device that can be activated using a 
normally open or normally closed switch.  One example of such a device would be the CONCOA telephone 
dialer (PN 5295306).

Connections to the Alarm are made through input and output connectors.  Customer supplied cables are easily 
soldered to the connectors prior to plugging the connectors into the Alarm.  For connector pin assignments 
please refer to the “CONNECTING THE ALARM” section of this manual.

GENERAL SAFETY PRACTICES

Basic safety precautions must be followed to reduce the risk of fire, electrical shock or injury.

a.  Connect the Alarm to the correct line voltage.  The product is supplied with either a 120 VAC or 

220VAC  wall mount power supply.

b.  While the Alarm is dust and moisture resistant, it should be installed in a location where it will not 

be subjected to rain or high concentrations of dust.  Never pour or spray liquids directly onto the 
product.

c.  Install the Alarm where the ambient temperature range while operating is between 0°F and 140°F.
d.  Do not install the product in hazardous locations.
e.  If product appears damaged in any way, do not use and request service from CONCOA.
f.  Do not attempt to operate the Alarm with the cover off.

DESCRIPTION OF PRODUCT

The Protocol Station Remote Alarm is capable of operating at either 120VAC or 220VAC depending on which 
wall mount power supply it was ordered with.  It is capable of providing operating status for a bank tanks for 
one CONCOA protocol system.  The Protocol Station Remote Alarm provides power to operate the pressure 
switches. 

A protocol product that is configured with the alarm option is equipped with one pressure switch gauge. A 
pressure switch gauge is used to monitor and report the state of the pressure for the Protocol System.  

Содержание 529 Series

Страница 1: ...Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Ju...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...to the connectors prior to plugging the connectors into the Alarm For connector pin assignments please refer to the CONNECTING THE ALARM section of this manual GENERAL SAFETY PRACTICES Basic safety pr...

Страница 4: ...ntrols one 1 set of relay contacts that are brought to the Output Connector so they may be used to control an external device When a system is operating normally the status indicator light will be gre...

Страница 5: ...a 6 conductor cable The length of the cable is determined by the application but should be limited to no longer than 1500 feet It is recommended that 22 AWG stranded wire be used Alpha 5006C is an acc...

Страница 6: ...is determined by the application but should be limited to no longer than 1500 feet It is recommended that 22 AWG stranded wire be used Alpha 5004C is an acceptable type Cut the 4 conductor cable to le...

Страница 7: ...activates a set of relay contacts in response to an alarm condition This set of relay contacts can be connected to any external device that is activated by the opening or closing of a switch Examples...

Страница 8: ...ng steps 1 Unplug the power plug from the Remote Alarm power jack 2 It is best to set the unit on a flat surface face down Remove the four 4 screws that hold the back cover on and set the cover aside...

Страница 9: ...rotocol Station and Alarm is not cut or pinched somewhere 3 Check to see that all the wires in the cable are properly soldered to the connectors Output does not appear to be functioning 1 Check the ca...

Страница 10: ...lcro Mounting Strips MOUNTING DETAIL ELECTRICAL SPECIFICATIONS Protocol Station Remote Alarm 120 Volt Version 120 Volts A10 50 60 hz 6VA 220 Volt Version 220 Volts A10 50 60 hz 6VA Fuses Internal Rese...

Страница 11: ...nyone other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OFAMERICA s sole and exclusive obligation and Buyer s...

Страница 12: ...5 www concoa com Qty Part Number Description 1 5295135 01 120 ASSY 120VAC PROTOCOL STATION REMOTE ALARM 1 5295135 01 220 ASSY 220VAC PROTOCOL STATION REMOTE ALARM INCLUDES 1 5295135 PROTOCOL STATION R...

Отзывы: