EN
37
VP 508x
40
VP5060
EN
1. Adjust the power controller to the minimum setting.
2. Insert the plug into the mains outlet.
3. Press the main switch on the vacuum cleaner.
4. Set the required suction power using the controller.
5. After vacuuming, turn off the product and unplug from the mains outlet.
6. To wind the power cord, press the holder in the back position to make it push against the winder button. Use your
other hand to make sure the power cord does not whip around.
CHECKING THE CONTAINER CONTENT LEVEL
If the suction power is lower, or the dust content level indicator is red even though the nozzle is lifted above the floor,
empty the container immediately.
NOTE: If the dust level indicator remains red after replacing the container, check for the following:
- One of the air passages is obstructed (hoses, telescopic tube, suction inlet, floor nozzle, or other adapters);
- The air inlet filter in the dust bin is fouled or old. Then it must be cleaned or replaced.
- The air outlet filter is fouled or old. Then it must be cleaned or replaced.
Check for each of the above possible causes and eliminate the problem before you resume vacuuming. If the cause of
the problem cannot be identified, take the product to the nearest service center. Never use the vacuum cleaner if the
container level indicator is completely red. The motor could be damaged irreparably.
MAINTENANCE
As a preventative measure, we recommend emptying the container and cleaning the
filters of the vacuum cleaner after each use.
EMPTYING THE CONTAINER
1. Unplug the vacuum cleaner from the mains. Disconnect the hose from the suction
inlet.
2. Push the latches on the container holder, and shift the container upwards (Fig. 3).
3. Press the latch on the bottom of the front side of the container, open the latch and
empty the contents of the container (see Fig. 4).
4. Turn-release and remove the filter cone. Clean the space above it. Follow the steps
in reverse to put it back, turn-lock.
5. Close the container and return it to the vacuum cleaner. Make sure the container is
positioned properly. You should hear a clicking sound from the handle latches.
REPLACING FILTERS
The filters should be replaced at least twice a year or whenever obviously fouled or
worn. The filters should be checked after each use of the vacuum cleaner.
Never use the vacuum cleaner without properly installed filters to avoid damage to
the vacuum cleaner.
Unplug the vacuum cleaner from the mains outlet before replacing the filters.
Suitable filter types are available from your local retailer, or they can be ordered from
the manufacturer.
(Obr. 3)
(Obr. 4)
41
VP5060
EN
CLEANING THE INLET FILTERS
1. Disconnect the flexible hose and remove the container.
2. Open the filter holder on the rear side of the container (Fig. 5) and remove the foam
rubber filter.
3. Push the button on the upper side of the HEPA filter and remove it (Fig. 6).
4. Both the foam rubber and HEPA filters may be cleaned mechanically by shaking
them and cleaning with a soft brush. Heavily fouled filters can be washed after this
step and cleaned with a soft brush in lukewarm water. Do not use detergents.
It
is important to let the wet parts dry thoroughly. Do not use a hair dryer for
drying! Wet filters will be damaged if used for vacuuming!
6. Assemble cleaned or new components and install them in the original location using
the reverse procedure.
Note: Wet cleaning can cause more wear and tear of the filter, and a correspondingly
shorter service life. If the vacuum cleaner does not perform with the original suction
power, the filters should be replaced with new ones.
CHECKING AND REPLACING THE AIR OUTLET FILTER
1. Open the air outlet grid at the rear section of the vacuum cleaner (see Fig. 7).
2. Remove the filter.
3. The filter can be cleaned by tapping or shaking it. If the filter is extremely dirty, it can
be washed in lukewarm water. Let the filter dry completely before using it again.
4. Insert a cleaned or new air outlet filter, and close the air outlet grid.
(Obr. 5)
(Obr. 6)
(Obr. 7)
CLEANING AND MAINTENANCE
The vacuum cleaner and its accessories can be cleaned with a wet cloth.
Do not immerse the power cord, plug, or appliance in water or any other liquid.
Do not use aggressive substances for cleaning, such as solvents or abrasives!
TROUBLESHOOTING
Problem
Cause
Solution
Motor out of operation
Plug inserted into the mains outlet
incorrectly or insufficiently.
Check the plug connection.
The mains outlet is not live.
Check for voltage, e.g. by connecting
another appliance.
Motor has stopped
operating
Improper or insufficient air flow. Motor
thermal protection activated.
Unplug the power cord from the
mains outlet.
Check and release the air
suction and discharge holes; check the
filter cleanliness and/or replace the dust
bag. Let the vacuum cleaner cool down.
CLEANING THE INLET FILTERS
1. Disconnect the flexible hose and remove the container.
2. Open the filter holder on the rear side of the container (Fig. 5) and remove the foam
rubber filter.
3. The foam rubber filter may be cleaned mechanically by shaking them and cleaning
with a soft brush. Heavily fouled filters can be washed after this step and cleaned
with a soft brush in lukewarm water. Do not use detergents. It is important to let
the wet parts dry thoroughly. Do not use a hair dryer for drying! Wet filters will be
damaged if used for vacuuming!
4. Assemble cleaned or new components and install them in the original location
using the reverse procedure.