Page
5
of
16
POSITIONING
The Smoke Screen should ideally be sited in a covert position away from prying eyes and thereby
reducing the possibility of tamper or an attack. The ideal place for the Smoke Screen is above a
ceiling from where the smoke plume is used to its best effect, bursting on the ground and
spreading outwards and upwards through 360°. If no suitable ceiling location is available then the
next best location is a wall mounting as close to ceiling height as possible.
Wall-mounting.
The optimum wall mounting position for the Smoke Screen is 2.5 metres above the floor facing the
area to be protected and using an appropriate angle nozzle. The maximum mounting-height above
floor level is 3 metres, the minimum is 1 metre and there should be no obstacle within 1 metre of
the smoke output nozzle.
Ceiling-mounting.
The optimum ceiling mounting height for the Smoke Screen is 2.5 metres above the floor over the
area to be protected and using a straight nozzle. The maximum mounting-height above floor level
is 3 metres and there should be no obstacle within 1 metre of the smoke output nozzle.
INSTALLATION PROCEDURE
1.
Site the Smoke Screen and fix the bracket to the wall or ceiling as appropriate.
2.
For wall mounting leave minimum 150mm clearance to ceiling.
3
Fasten the Smoke Screen to the bracket and open front cover.
4.
Make connections as required to the Alarm Panel and Hold-off PIR.
5.
Make connection to the Exagon panel (if used) and set the key switch to isolate mode.
6.
Connect mains power (230-volt AC, 50Hz).
7.
The Smoke Screen will heat up to operating temperature in approximately 20 minutes.
8.
Set correct time/date and smoke timing for the specified room size.
9.
Ensur
e the “Service Mode” dip switch No 3 is selected to “Off”.
10.
With the power applied
insert fluid bag and make sure the fluid switch is closed correctly.
11.
Make sure all tamper switches are closed and you are ready for test.