Page
13
of
16
LCD, LED AND SOUND INDICATIONS
The Smoke Screen provides onboard status monitoring via an LCD, a multicolour LED and a sounder. Indications displayed are:
LCD Message
LED Colour
Buzzer Sound
Relay status change
Indication Meaning
Heating up
●
permanent.
Nil.
Nil.
Smoke Screen heating to
operating temperature.
Heating Completed
●
permanent.
Nil.
Nil.
Smoke Screen ready to
operate.
Charging Battery
●
●
flash once every 5 sec. Nil.
Nil.
Battery charging.
Alarm Set
●
permanent.
Nil.
Nil.
Smoke Screen has received
a “Set” input from the Alarm
Panel.
--
●
flash.
1 beep every 0.5 sec.
Verification output n/c to open.
Smoke Screen producing
smoke.
Thermal Fault
●
permanent.
1 long / 3 short beeps every 3
mins.
Status output n/c to open.
Temperature too high or
sensor failure.
Heater Fault
●
●
flash once every 5 sec. 1 long 2 short beep every 3 min.
Status output n/c to open
Smoke Screen not heating at
the correct rate within 30 min
of power on.
Empty Fluid
●
●
flash once every 5 sec. 1 long beep every 3 min.
Liquid output n/c to open.
Status output n/c to open.
Fluid less than 10ml or no
Bladder installed.
Low Fluid
●
●
flash once every 5 sec. 1 short beep every 5 min.
Liquid output n/c to open.
Fluid less than 50%.
Battery Fault
●
●
●
flash once every 5 sec. 3 short beep every 5 min.
Battery output n/c to open.
Battery lower than 18V or
battery removed > 2 min.
Tamper Fault
●
flash once every 5 sec. 2 short beep every 5 min.
Tamper status n/c to open.
One or more of the access
panels, or the external
tamper if dip set to “off”, are
open.
Mains Fault
●
flash once every 5 sec. 1 long 1 short beep every 3 min.
Status output n/c to open.
Main power failure.
System Fault
Any
Any
Status output n/c to open.
Critical system fault.
Service Mode Setting
●
●
alternate flash.
Nil.
Nil.
Smoke Screen in Service
Mode.
Once resolved, fault indications can be cleared by removing and restoring all power, mains and battery, from the Smoke Screen.