7.3 THERMAL CUT-OUT (TCO) RESET
Be aware of high voltage in
the block area. The
electrical supply should be
switched off before working
in the heater block
compartment.
This operation is usually carried out
during installation. If the Smoke Screen
has been in service the nozzles will be
extremely hot and
will cause injury if touched. Therefore,
the Smoke Screen should be switched
off and time should be allowed for the
nozzles to cool.
In the unlikely event that the temperature in the heater block increases significantly above the set working
temperature the TCO will trip to protect the machine from damage. The TCO can be reset using the following
procedure:
•
Make sure the mains power to the machine is turned off before resetting the TCO.
•
Reset the TCO by pressing on the little button on the top area that is accessed through the hole in
protective cover (see photo below). If the thermal device has tripped it should be possible to hear a
click when it resets.
•
Switch on the mains power after resetting.
•
Check the machine heats up to normal operating temperature and make sure it archives a ready state.
See the operating “LCD, LED and Sound Indications” for further information on fault indications.
NB: A TCO usually only trips if there is a problem. If it trips again the Smoke Screen should be checked for
faults before further use.
Note: The position of the TCO can be different depending on the machine version