background image

29 

Содержание Sentinel S35v6

Страница 1: ...1 SENTINEL S35v6 INSTALLATION AND OPERATION Version November 2020 MANUAL ...

Страница 2: ...s worth of property defeating criminals and securing premises on an almost daily basis We produce them because we believe you have a right to feel safe and secure Please take the time to read and understand this guide to ensure you achieve the maximum performance from your Smoke Screen If you have any questions that remain unanswered please call our experts at Concept Smoke Screen and we will help...

Страница 3: ...iagram 11 12 5 Settings 13 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5 10 Screen sensor Energy saving mode Verification timer Service mode Inverting triggers Tamper Reboot Fluid management Battery management Programming 13 13 13 14 14 14 14 15 17 18 6 Commissioning 20 6 1 6 2 Operation Testing 20 20 7 Servicing 21 7 1 7 2 7 3 7 4 7 5 Live Status LCD LED and sound indications Thermal cut out TCO reset Ac...

Страница 4: ...ing signs or a variation may be used for safety notices in this manual or on the Smoke Screen This type of warning note is used to indicate possible electrical shock hazards that may cause serious injuries or death This type of warning note is used to indicate the possibility of injury caused by hazards other than electrical shock 1 2 HOW DOES YOUR SMOKE SCREEN WORK Your Smoke Screen passes a non ...

Страница 5: ...zzle for wall mounted installation You will also need Mains power supply an unswitched 13 amp fused spur connected to a dedicated breaker Connections into the alarm panel or other triggering system PIR or equivalent to provide the hold off where required 1 4 OVERVIEW The Smoke Screen is designed to form part of an existing intruder alarm system but may also be configured as a stand alone system or...

Страница 6: ...upplied by an alarm control panel or equivalent in the form of an N C normally closed or an N O normally open relay changing state when the alarm system is set for operation An Alarm command supplied by the alarm control panel or equivalent in the form of an N C normally closed or an N O normally open relay changing state when the alarm system confirms an intruder alert A Panic command in the form...

Страница 7: ...m wall mounting position for the Smoke Screen is 2 5 metres above the floor facing the area to be protected and using the 30 degree angle nozzle The maximum recommended mounting height above floor level is 3 metres the minimum is 1 metre and there should be no obstacle within 1 metre of the smoke output nozzle Also leave a minimum of 150mm clearance to the ceiling Ceiling mounting The optimum ceil...

Страница 8: ...TING The Smoke Screen can be mounted on a ceiling or a wall using the simple standard bracket supplied with the unit This flush fitting bracket maximizes security by concealing all the mounting fastenings such that they can only be accessed or the Smoke Screen dismounted by dismantling the unit Moreover the Smoke Screen has a tamper protection switch to provide an alert in the unlikely event that ...

Страница 9: ...s the nuts and the threaded bar will take the weight of the Smoke Screen The final assembly viewed through the ceiling is in the photo Any hole made in the ceiling below can be made good with a cosmetic hole surround 2 5 NOZZLE CHANGING To change the nozzle first remove the front cover then remove and replace the nozzle using a 10mm ring spanner sealing it with PTFE tape and ensuring that an angle...

Страница 10: ...ons Additional hold off any form of normally closed relay micro switch can be connected to the Hold off connections Where fitted in parallel as an addition to a PIR both devices must be open to produce smoke Panic activation The Smoke Screen has a Panic input that should be connected to a clean contact going open circuit to activate this can be changed to closed activate see Invert Trigger Mode in...

Страница 11: ... the option to select the following options for subsequent re triggers initiated by a hold off if the Set and Alarm remain in alarm Delay Repeat activations are delayed by the Delay Time set Instant Repeat activations are instantaneous Stopping an activation Once activated the Smoke Screen will stop producing smoke before the end of the programmed smoke time only if the Set is restored to a non al...

Страница 12: ...11 Connections 4 4 1 CIRCUIT BOARD LAYOUT ...

Страница 13: ...12 4 2 GENERIC CONNECTION DIAGRAM ...

Страница 14: ...rmal operating temperature NB If the Smoke Screen is in ESM mode and is activated as soon as the alarm is set ie before it has heated to normal operating temperature it will still produce smoke but the length of time of the initial burst of fog will be shortened Extreme When Extreme is selected and the alarm panel input to the Smoke Screen is Unset the Smoke Screen heater is not operated and its t...

Страница 15: ...tamper input on PCB terminal block B A Tamper Status output is provided on PCB terminal block F To prevent unwanted tamper signals the external tamper input can be disabled if not in use by selecting dip switch 2 to On which bridges the input pins on the PCB NB A tamper open state provides only an indication of the event it does not automatically activate the Smoke Screen or prevent it from activa...

Страница 16: ...in service the heater block and connected parts will be extremely hot and will cause injury if touched Switch off and allow the heater block to cool Changing a fluid consumable Obtain a replacement fluid consumable from your Smoke Screen supplier Ensure that power is applied to the Smoke Screen this should be only battery power and remove the Smoke Screen cover ...

Страница 17: ...FLUID CONSUMABLE HOLDER MICRO SWITCH IS RESET FAILURE TO DO SO MAY RESULT IN DAMAGE TO THE FLUID PUMP THE SMOKE SCREEN WILL NOT PRODUCE FOG IF THE CONSUMABLE NECK IS NOT CORRECTLY FITTED TO THE HOLDER AND THE MICRO SWITCH IS NOT CLOSED External reservoir A 5000ml external reservoir can be used with Smoke Screen please contact Concept Smoke Screen if you wish to use this function ...

Страница 18: ... power failure at which time the unit is too cold to activate the Smoke Screen will start up normally as soon as mains power is re applied Battery switch The Smoke Screen has a switch on the PCB to permit the batteries to be disconnected from the system whilst remaining in place see the picture above The delivery setting is Off select to On if intending to use the battery facility Removal and repl...

Страница 19: ...urn the LCD to the Live Status display Viewing and setting the functions and variable parameters In the Smoke Screen Status or Current Time display Press Function Escape to access the programmable functions Press Up or Down buttons to scroll through the available functions Press Enter Back to view the current function setting Press Up or Down buttons to scroll through the available parameters Pres...

Страница 20: ...e The PCB mounted battery switch is Off on delivery See Section 5 8 Enable Disable ESM Disable Disable ESM Extreme Energy Saving Mode See Section 5 2 Smoke Delay 0 seconds 0 to 60 seconds in 1 second intervals See Section 3 1 Re triggering Delay Delay Instant Available if Smoke Delay set to 0 seconds Select Delay to apply set Smoke Delay time to every re trigger by the Hold off Instant no delay Se...

Страница 21: ...again 6 2 TESTING Full alarm test Where possible a full alarm test should be conducted to check all inputs outputs and wiring connections to the Smoke Screen are correct The Smoke Screen will fire for the designated Smoke Time once the Alarm Set Trigger and Hold off if fitted contacts are open It will re trigger if the Alarm Set remains open and either the Trigger and or the Hold off inputs are cy...

Страница 22: ...L Low Fluid The Swift Fit fluid level is less than 50 TI Tamper Internal The Tamper Output is giving a tamper alarm Bottom Line Inputs Indication Meaning Explanation S Set The Set input is armed A ALARM The Alarm input is in an alarm state Ho Hold off The Hold off input is in an alarm state PA Panic The Panic input is in an alarm state Sm Service Mode The Service Mode Dip switch is selected on ES ...

Страница 23: ...22 7 2 LCD LED AND SOUND INDICATIONS The Smoke Screen provides on board status monitoring via an LCD a multicolour LED and a sounder Indications displayed are ...

Страница 24: ...damage The TCO can be reset using the following procedure Make sure the mains power to the machine is turned off before resetting the TCO Reset the TCO by pressing on the little button on the top area that is accessed through the hole in protective cover see photo below If the thermal device has tripped it should be possible to hear a click when it resets Switch on the mains power after resetting ...

Страница 25: ...s that the Smoke Screen is serviced replenished by an engineer certified by the manufacturer If you are unsure ask the engineer for their certification ID card Smoke Screen servicing To ensure the Smoke Screen remains fully operational it must be regularly serviced by a Concept Smoke Screen certified engineer Failure to service the Smoke Screen may invalidate the warranty Service intervals The Smo...

Страница 26: ... SSI to Smoke Screen SM Service Mode Smoke Screen is isolated for repair installation Settle Timer Time after the Smoke Screen is Set during which it will not react to a Hold off input Use for PIR settling time on exit Smoke Fog The Smoke Screen makes a fog rather than produces smoke Smoke Delay Time after an activation demand before the Smoke Screen activates Smoke Mode Setting that varies the in...

Страница 27: ... and are members of the Comply Direct WEEE compliance scheme Comply Direct have registered us with the Environment Agency as a Producer and will arrange to have any of our equipment collected and recycled as necessary Comply Direct can be contacted on 0844 873 1034 If arranging a collection please quote our membership number which is CD01 00593 Our Environment Agency Producer Registration number i...

Страница 28: ...ety standards or specifications or any other costs to adjust the product as a result of any specifications which have changed since the delivery of the product Damage resulting from the fact that a product is not conforming to country specific standards or specifications in another country than the country of purchase Warranty repair service is excluded if the equipment has not been serviced on as...

Страница 29: ...pair CSS shall not be liable for any incidental or consequential damages for breach of any express or implied warranty of this product These warranty terms and conditions are offered to you by CSS without prejudice to any statutory rights that you may additionally have with regard to the products covered by these terms and conditions ...

Страница 30: ...29 ...

Страница 31: ...Version November 2020 Concept Smoke Screen Limited North End Business Park Station Rd Swineshead Lincolnshire PE20 3PW United Kingdom Tel 44 0 1205 821111 Fax 44 0 1205 820316 info smoke screen co uk www smoke screen com ...

Отзывы: