Use this procedure to safely stop the servo cutter:
Press Cut On/Off soft key
to stop cutting (soft key
text changes to off).
Press Stop Cutter button
to disable the servo motor
(start light is off).
Turn the rotary disconnect to the off posi-
tion.
Disconnect the power cord
if it is equipped with
a plug on the end.
Lock out the rotary disconnect.
Clean the lubricant reservoir
if you are shutting
the servo cutter down for the day.
S
TOPPING THE
SC-5 C
UTTER
O
PERATION
4-31
WARNING: Never stop the servo cut-
ter by opening the knife guard.
This can cause damage to the equipment and
injury to personnel.
WARNING: Never turn off the rotary
disconnect first.
Doing so will turn off all power to the unit, and
the cutter will not be brought to a controlled
stop. For safe stopping, always follow the
sequence given above.
1
2
3
4
5
6
UGE059/1003
SC-5 SURE CUT Servo Knife Cutter