2-10
I
Hopper Installation Guide
Installing the Drying Monitor Probe
From the Top of the Drying Hopper
(continued)
5
Place the adapter plates over the gasket and secure
them to the hopper with three (3) 10-32 UNF screws.
Make sure the adapter plate with the threaded hole is on
the bottom, and that the slots in the adapter plates are
oriented in the opposite direction as shown
(See the drawing below).
6
Secure the coupling to the adapter plates
with the
four (4) 10-32 UNF screws.
7
Screw the fitting into the coupling.
Tighten with
an appropriately-sized wrench.
8
Make sure the probe is the correct size.
The probe should extend from just above
the top of the hopper into the hopper, with the tip approximately inline with the
bottom edge of the diffuser cone.
9
Push the compression sleeve into the fitting.
10
Tighten the nut over the sleeve.
The compression sleeve will crimp
the tube to hold the probe in place.
Be sure to position the connector in
such a way as to avoid interference of
the cable with the receiver, etc. Use an
appropriately-sized wrench to tighten
the nut so that it 7 covers the threads.
DM Probe
Location
Nut
Sleeve
Fitting
Coupling
Adapter
plate
Gasket
Hopper
Threaded
adapter
plate
10
9
7
6
5
4