29
COMUNELLO
®Copyright 2021 - All rights reserved
ENGLISH
DIP SWITCH SW1
The SW1 Dip-Switches allow you to select the 1 or 2 motor function
and define which of the two motors starts first and which second.
TRIMMER SENS:
It regulates the SENSITIVTY of motors
1
1
ON
2
MOTEUR
NON PRIS
EN COMPTE
2
MOTEURS
RETARD
MOT. 2
2
MOTEURS
RETARD
MOT. 1
1
ON
2
1
ON
2
SW1
SW1
SW1
Turning with a screwdriver towards the + increases the speed of the
motor stroke during the slowing down phase
DIP SWITCH SW2
The SW2 Dip-Switches allow to change the direction of stroke
of each motor without physically intervening on the electrical
connections in the terminal block.
TRIMMER SPEED:
It regulates the SPEED of motors
INV
1
ON
2
OFF
INV
OFF
INV
MOT 1
INV
OFF
INV
OFF
INV
MOT 2
INV
MOT 1
INV
MOT 2
1
ON
2
1
ON
2
1
ON
2
SW2
SW2
SW2
SW2
Turning with a screwdriver towards the + increases the motor speed
during the stroke.
TRIMMER SLOWING:
It regulates the slowdown speed of motors
Turning with a screwdriver towards the + increases the sensitivity and
therefore the motor will block its stroke more quickly if an obstacle is
detected.
2 WIRES CONNECTION TABLE:
TAB.01
n°
DESCRIPTION
CABLE
LENGTH from 1m to 20m
LENGHT from 20m to 50m
1
Power supply
EN standard 50575, in
the list of harmonized
rules for the Regulation
CPR 305/2011, Com.
2016/C 209/03
2 x 1.5 mm
2
2 x 2.5 mm
2
6A
Motor power supply
2 x 2.5 mm
2
2 x 4.0 mm
2
2
Flashing light
2 x 0.5 mm
2
2 x 1.0 mm
2
4A, 5A
TX photocell
2 x 0.5 mm
2
2 x 1.0 mm
2
4B, 5B
RX photocell
4 x 0.5 mm
2
4 x 1.0 mm
2
6
Key selector
3 x 0.5 mm
2
3 x 1.0 mm
2
6B
Limit switches
3 x 0.5 mm
2
3 x 1.0 mm
2
6C
Encoder
3 x 0.5 mm
2
3 x 1.0 mm
2
3
Antenna
RG58
Max. 20m
The table refers to the example of wiring shown in the ABACUS model manual for swing motors.
If the cables are of a different length than those shown in the table, the section of the cables must be determined based on the actual absorption of the connected
devices.
Содержание QUAD 24V HP
Страница 3: ...3 COMUNELLO Copyright 2021 All rights reserved FIG 1 FIG 3 FIG 2 MAX 20mm 30mm AC 52 FIG 3B FIG 3C...
Страница 25: ...25 COMUNELLO Copyright 2021 All rights reserved NOTES...
Страница 67: ...67 COMUNELLO Copyright 2021 All rights reserved NOTES...
Страница 89: ...89 COMUNELLO Copyright 2021 All rights reserved NOTES...
Страница 111: ...111 COMUNELLO Copyright 2021 All rights reserved NOTES...
Страница 133: ...133 COMUNELLO Copyright 2021 All rights reserved NOTES...
Страница 135: ...135 COMUNELLO Copyright 2021 All rights reserved 2 2 2 62 7 0 7 0 59 4 4 2 383 2 2...
Страница 155: ...155 COMUNELLO Copyright 2021 All rights reserved NOTES...