Comunello CU-24V-1M Скачать руководство пользователя страница 4

SEL

SET

F2

SPEED SENS

1 ST

2 ND

L     N

ANTENNA

PULSANTE APRI-CHIUDI (N.O.)

PUSCH BUTTON (N.O.)

ALIMENTAZIONE FOTOCELLULE

PHOTOCELL POWER

24V     5W

FINECORSA APRI (N.C.)

END OPEN (N.C.)

+

FINECORSA CHIUDI (N.C.)

END CLOSE (N.C.)

FOTOCELLULA - DS (N.C.) ATTIVA IN CHIUSURA

PHOTCELL - DS (N.C.) ACTIVE IN CLOSING

FOT+

GND

STOP

GND

GND

FCA

DS1

GND

PP

ANT

ANT+

FCC

CN2

LAMPEGGIANTE

FLASHING LIGHT

24V      4W

CN1

M

MOTORE

MOTOR

24V

TRASFORMATORE

TRANSFORMER

230/21.7V - 7.5A

CN5

CN4

CN3

L24

L24

M1+

M1

LINEA

POWER SUPPLY

230V     50Hz

+

BATTERIA TAMPONE

BACK-UP BATTERY

F1

2 ND BATT

BLOCCO (N.C.)

STOP (N.C.)

Содержание CU-24V-1M

Страница 1: ...USER S MANUAL Control unit comunello com ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCIONS D UTILISATION ET D INSTALLATION INSTRUCCIONES DE USO Y DE INSTALACION Cod...

Страница 2: ...ON OFF L5 RELEASE STROKE ON OFF L6 SLAM LOCK ON OFF L7 COURTESY LIGHT ON OFF LEV LEV 1 FLASH ID LED L1 SOFT STOP ON OFF L2 SOFT START ON OFF L3 DS 1 IN OPEN ON OFF L4 HOLD TO RUN ON OFF L5 FOLLOW ME...

Страница 3: ...C 24V SLIDING GATE CU 24V 1M ID Description Cable type Lenght 1m to 20m Lenght 20m to 50m 1 Main power supply FG7 CEI 20 22 CEI EN 50267 2 1 2x1 5mm2 2x2 5mm2 2 Flashing light 2x0 5mm2 2x1 0mm2 4A 6A...

Страница 4: ...RSA CHIUDI N C END CLOSE N C FOTOCELLULA DS N C ATTIVA IN CHIUSURA PHOTCELL DS N C ACTIVE IN CLOSING FOT GND STOP GND GND FCA DS1 GND PP ANT ANT FCC CN2 LAMPEGGIANTE FLASHING LIGHT 24V 4W CN1 M MOTORE...

Страница 5: ...reserved ITALIANO FORT like below Led opening direction OFF OPENS TO THE RIGHT Inner side view OPENING DIRECTION 1 MOTOR CONFIGURATION FORT FORT like below Led opening direction ON OPENS TO THE LEFT I...

Страница 6: ...SALIENT DO NOT CHANGE the configuration Opens to the left closes to the right left profile view as in the image SALIENT BLACK ON M1 RED ON M1...

Страница 7: ...directives 2004 108 EC Directive EMC Directive 2006 95 CE Directive and that all the rules and or technical specifications shown below have been applied EN61000 6 2 EN61000 6 3 EN62233 2008 EN301489 1...

Страница 8: ...The rear of the box is equipped with knockouts for wall fixing knockouts for fixing holes using anchor bolts or holes for fixing with screws Take all the measures required to ensure the installation p...

Страница 9: ...ttons are used to control the gate operation is as follows the first command opens the gate until motor time or until the gate reaches its opening limit position the second command closes the gate if...

Страница 10: ...the latter will be controlled thus effectively relinquishing the security of the rolling code system 4 CONDO The Condominium function means that during the opening movement or during the pause time th...

Страница 11: ...become steady on and programming will be completed Repeat the procedure if you wish to restore the previous configuration 2 PED MOT T Programming of pedestrian opening motor time of max 4 minutes The...

Страница 12: ...upward each additional LED corresponds to a higher power level Use the SEL key to scroll through the different power levels for each selected power level the top LED will blink for example selecting l...