Repeat the procedure if you wish to restore the initial configuration.

4. HOLD-TO-RUN:

The control unit provides the opportunity to set the “Hold-to-run” function. 
If you wish to enable the function, proceed as follows: ensure you have 
enabled Extended Menu 2 and then use the SEL key to select blinking LED 
L4 and press the SET key; at the same time LED L4 becomes steady on 
and the operation will be completed. With this function enabled using either 
the remotes or the Pushbuttons to operate the gate, the following operation 
will be obtained: the command must be maintained constantly to move 
the gate. When the command is released movement will stop immediately. 
Repeat the procedure if you wish to restore the previous configuration.

5. FOLLOW ME

The control unit allows the “Follow me” function to be configured; 
programmable only if a Pause Time has already been set, this function 
reduces the Pause Time to 5 seconds after freeing the SAFE1 photocell, 
meaning the gate re-closes 5 seconds after transit of the user. To activate 
this function proceed as follows: ensure you have enabled Extended 
Menu 2 and then press the SELECT key to select blinking LED L5 and 
then press the SET key: LED L5 becomes steady on and programming will 
be completed. Repeat the procedure if you wish to restore the previous 
configuration.

6. FLASHING LIGHT OPERATION

The control unit is factory set with Flashing Light during Pause Time 
disabled. If you wish to enable this function, proceed as follows: make 
sure you have enabled Extended Menu 2, press the SELECT key to select 
blinking LED L6 and then press the SET key: LED L6 becomes steady on 
and programming will be completed. Repeat the procedure if you wish to 
restore the previous configuration.

7. ALWAYS CLOSE

The control unit provides the facility to set “Always Close” operation: this 
function, which is programmable only if a Pause Time has already been 
programmed, is activated after a power loss; if the gate open condition 
is confirmed a closing movement is started automatically, preceded by 
5 seconds of preflashing. If you wish to enable the function, proceed as 
follows: ensure you have enabled Extended Menu 2 and then use the SEL 
key to select blinking LED L7 and press the SET key; at the same time LED 
L7 becomes steady on and the operation will be completed. Repeat the 
procedure if you wish to restore the previous configuration.

EXTENDED MENU 3

The control unit is factory set to allow direct selection exclusively of the main 
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed 
as follows: select blinking LED no. 8 and press SET 3 times. The LED will 
start blinking alternately 1 1 1 0 1 1 1 0 1 1 1 0. This means there is a 
period of 30 seconds to select the functions in Extended Menu 3 using the 
SEL and SET keys and then, after a further 30 seconds, the control unit will 
revert to the main menu.

EXTENDED MENU 3

level

L1

1

LED 1

L2

2

LED 1 +LED 2

L3

3

LED 1 +LED 2 +LED 3

L4

4

LED 1 + LED 2 +LED 3 +LED 4

L5

5

LED 1 + LED 2 +LED 3 +LED 4 +LED 5

L6

6

LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6

L7

7

LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7

LEV

MENU

3 FLASHIES

DECELERATION FORCE ADJUSTMENT:

Operator force during the deceleration stage can be programmed on the 
control unit. You can select one of 7 different power levels as follows; ensure 
you have enabled Extended Menu 3; each combination of lit LEDs defines 
a level as shown in the above table; in practice, starting from the bottom 
LED (LED 1) and proceeding upward, each additional LED corresponds to 
a higher power level. Use the SEL key to scroll through the different power 
levels; for each selected power level the top LED will blink (for example, 
selecting level 4, LED 1 + LED 2 + LED 3 will be steady on, while LED 4 will 
blink); press SET to confirm. Factory setting: level 3 selected.

RESET:

If it becomes necessary to reset the control unit to restore the factory 
settings, press the SELECT and SET keys together; this will cause all the 
RED indicator LEDs to light simultaneously followed immediately by the 
control unit switching off

DIAGNOSTICS:

Photocell Test:

The control unit is prearranged for connection of safety devices in 
compliance with standard EN 12453 point 5.1.1.6. At each operating 
cycle a functional test of the connected photocell is performed. In the case 
of an open circuit and/or malfunctioning of the photocell, the control unit 
does not enable movement of the gate and visually signals the test failed 
condition by causing all the indicator LEDs to blink simultaneously. As soon 
as correct operation of the photocell is restored the control unit is ready for 
normal use. This operating mode guarantees failure mode monitoring in 
compliance with EN 954-1 Category 2

Commands input test:

In correspondence with each low voltage command input the control unit 
is equipped with an indicator LED so that the status of the input can be 
checked at a glance. Operating logic: LED on input closed, LED off input 
open.

WARRANTY

Fratelli Comunello SpA provides a warranty for 24 months for the correct 
functioning of the actuators from the date of manufacture, provided that the 
performance specications indicated in the product instruction manuals are 
respected. Free of charge repair and replacement of components that are 
found to be faulty according to the indisputable judgment of the company’s 
technical staff shall be guaranteed at the sole discretion of Fratelli Comunello 
Spa, and so excluding any claim for damages made by others. Warranty 
material shall be returned to Fratelli Comunello S.p.a. headquarters carriage 
paid and will then be shipped to the customer carriage unpaid. The material 
found to be faulty and returned to Fratelli Comunello S.p.a. shall remain 
property of the Seller. Any cost resulting from any work needed to repair 
the defect or to replace the material shall be charged to the Buyer. No 
compensation shall be allowed for the period of device inactivity. Work under 
warranty does not prolong the warranty period. The defect of the product 
shall be reported by the Buyer within 8 (eight) days from its discovery or 
from the date of delivery of the goods, under penalty of invalidation of the 
warranty. Such claim shall be notied in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during 
transport; any defect or damage arising from any fault and/or from neglect, 
inadequacy and misuse of the electrical wiring in the Buyer’s property; any 
defect or damage caused by any repairs carried out by non authorised 
personnel or by incorrect use/installation (with reference to this, system 
maintenance is recommended every 6 months) or if not original spare parts 
are used; any defect caused by chemicals or atmospheric conditions. The 
warranty does not cover any cost neither for consumable materials nor for 
alleged defects or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to 
continue changes and improvements; their technical features and image 
may therefore change without previous notice.
Competent court
Since the contract of sale is conrmed by an Order Conrmation drawn up 
in Rosà, any such dispute shall be settled by the laws of Italy and by the 
court of Vicenza (VI).

Содержание CU-24V-1M

Страница 1: ...USER S MANUAL Control unit comunello com ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCIONS D UTILISATION ET D INSTALLATION INSTRUCCIONES DE USO Y DE INSTALACION Cod...

Страница 2: ...ON OFF L5 RELEASE STROKE ON OFF L6 SLAM LOCK ON OFF L7 COURTESY LIGHT ON OFF LEV LEV 1 FLASH ID LED L1 SOFT STOP ON OFF L2 SOFT START ON OFF L3 DS 1 IN OPEN ON OFF L4 HOLD TO RUN ON OFF L5 FOLLOW ME...

Страница 3: ...C 24V SLIDING GATE CU 24V 1M ID Description Cable type Lenght 1m to 20m Lenght 20m to 50m 1 Main power supply FG7 CEI 20 22 CEI EN 50267 2 1 2x1 5mm2 2x2 5mm2 2 Flashing light 2x0 5mm2 2x1 0mm2 4A 6A...

Страница 4: ...RSA CHIUDI N C END CLOSE N C FOTOCELLULA DS N C ATTIVA IN CHIUSURA PHOTCELL DS N C ACTIVE IN CLOSING FOT GND STOP GND GND FCA DS1 GND PP ANT ANT FCC CN2 LAMPEGGIANTE FLASHING LIGHT 24V 4W CN1 M MOTORE...

Страница 5: ...reserved ITALIANO FORT like below Led opening direction OFF OPENS TO THE RIGHT Inner side view OPENING DIRECTION 1 MOTOR CONFIGURATION FORT FORT like below Led opening direction ON OPENS TO THE LEFT I...

Страница 6: ...SALIENT DO NOT CHANGE the configuration Opens to the left closes to the right left profile view as in the image SALIENT BLACK ON M1 RED ON M1...

Страница 7: ...directives 2004 108 EC Directive EMC Directive 2006 95 CE Directive and that all the rules and or technical specifications shown below have been applied EN61000 6 2 EN61000 6 3 EN62233 2008 EN301489 1...

Страница 8: ...The rear of the box is equipped with knockouts for wall fixing knockouts for fixing holes using anchor bolts or holes for fixing with screws Take all the measures required to ensure the installation p...

Страница 9: ...ttons are used to control the gate operation is as follows the first command opens the gate until motor time or until the gate reaches its opening limit position the second command closes the gate if...

Страница 10: ...the latter will be controlled thus effectively relinquishing the security of the rolling code system 4 CONDO The Condominium function means that during the opening movement or during the pause time th...

Страница 11: ...become steady on and programming will be completed Repeat the procedure if you wish to restore the previous configuration 2 PED MOT T Programming of pedestrian opening motor time of max 4 minutes The...

Страница 12: ...upward each additional LED corresponds to a higher power level Use the SEL key to scroll through the different power levels for each selected power level the top LED will blink for example selecting l...

Страница 13: ...FRATELLI COMUNELLO S P A AUTOMATION GATE DIVISION Via Cassola 64 C P 79 36027 Ros Vicenza Italy Tel 39 0424 585111 Fax 39 0424 533417 info comunello it www comunello com...

Отзывы: