SLM-5650 Satellite Modem
Revision 1
Remote Control
MN/SLM5650.IOM
B–12
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx Differential
Encoding
TDE=
1 byte
Command or Query.
Tx Differential Encoding, where:
x=Tx Differential Encoding, where:
0=Off
1=On
Depending on FEC type or Modulation Type, not all of these
selections will be valid.
Example: TDE=1 (selects Tx Differential Encoding On)
TDE=
TDE?
TDE*
TDE#
TDE? TDE=x
(see description of
arguments)
Tx Power
Level
TPL=
5 bytes
Command or Query.
Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: TPL=-13.4
TPL=
TPL?
TPL*
TPL#
TPL?
TPL=sxx.x
(see description of
arguments)
Tx Clock
Source
TCK=
1 byte
Command or Query.
Tx Clock Source, where:
x=Tx Clock Source, where:
0=Internal
1=Tx Terrestrial
Example: TCK=1 (selects Tx Terrestrial Clock Source)
TCK=
TCK?
TCK*
TCK#
TCK?
TCK=x
(see description of
arguments)
Tx SCT
Reference
SCT=
1 byte, value
of 0 thru 2
Command or Query.
SCT Clock Reference, where:
x=SCT Clock Reference, where:
0=Internal
1=Data Source Synchronized
2=Rx-Satellite Clock
Example: SCT=0 (selects Internal Modem Reference)
SCT =
SCT?
SCT*
SCT#
SCT?
SCT=x
(see description of
arguments)
Содержание SLM-5650
Страница 2: ......
Страница 50: ...SLM 5650 Satellite Modem Revision 2 Installation MN SLM5650 IOM 2 12 This page is intentionally left blank...
Страница 162: ...SLM 5650 Satellite Modem Revision 1 Remote Control MN SLM5650 IOM B 40 This page is intentionally left blank...
Страница 175: ...SLM 5650 Satellite Modem Revision 1 Ethernet Management MN SLM5650 IOM D 9 COMTECH EF DATA SLM 5650 TELNET INTERFACE...
Страница 176: ...SLM 5650 Satellite Modem Revision 1 Ethernet Management MN SLM5650 IOM D 10...
Страница 186: ......
Страница 188: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...