SLM-5650 Satellite Modem
Revision 2
Front Panel Operation
MN/SLM5650.IOM
4–20
Select: CONFIG: Remote: Remote: Serial: Interface
If
Interface
was selected:
Select
RS232
,
RS485-2W
(2-wire), or
RS485-4W
(4-wire), or TTL (Switching)
using
the
arrow keys, then press [
E
]. The TTL (Switch) selection enables
interoperation with the CRS-311 (1:1) or CRS-300 (1:N) switch.
IMPORTANT
When selecting RS-232 the local M&C bus address displays, 0000.
Addressing is not supported by RS-232 or TTL (Switch)because they
are not a multi drop communication standards. If RS-485 is selected,
the display will show address 0001. This address can be changed
using the front panel. The most significant digit is for Comtech EF
Data redundancy switches.
Select: CONFIG: Remote: Remote: Serial: Interface: Baudrate
If
Baudrate
was selected:
IMPORTANT
The only asynchronous character format supported is 8 bits data, No
parity and 1 stop bit.
M&C Bus Interface: RS232 RS485-2W
RS485-4W TTL (Switching) (
ef
E)
Local M&C Bus Address:
0000
Local M&C Bus Baud Rate:
38400 Baud
(
bc
E)
Содержание SLM-5650
Страница 2: ......
Страница 50: ...SLM 5650 Satellite Modem Revision 2 Installation MN SLM5650 IOM 2 12 This page is intentionally left blank...
Страница 162: ...SLM 5650 Satellite Modem Revision 1 Remote Control MN SLM5650 IOM B 40 This page is intentionally left blank...
Страница 175: ...SLM 5650 Satellite Modem Revision 1 Ethernet Management MN SLM5650 IOM D 9 COMTECH EF DATA SLM 5650 TELNET INTERFACE...
Страница 176: ...SLM 5650 Satellite Modem Revision 1 Ethernet Management MN SLM5650 IOM D 10...
Страница 186: ......
Страница 188: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...