KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Appendix C
MN/KPA.IOM
C–14
Parameter Type
Command
(Instr Code and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes, i.e., ASCII codes between 48 and 57)
Query
(Instr Code and
Qualifier)
Response to Query
(Target to controller)
FET Current
status
N/A
variable length
Query only.
Used to display all the FET currents.
Q01 and Q02 are in mA.
All other FETs are in Amps.
If it is not applicable, it will display xx.x.
Example: RFS?
Q01=xx.x’cr’
Q02=xx.x’cr’
Q03=xx.x’cr’
Q04=xx.x’cr’
…
Q32=xx.x’cr’
Q33=xx.x’cr’
Q34=xx.x’cr’’lf’
RFS?
RFS=x….x
(see Description of
Arguments)
Retrieve
Maintenance
Status
N/A
variable length, alpha
numerical
Query only.
Used to query the maintenance status of the unit.
Example: <0001/RMS?
>0001/RMS=
V+28=+27.8
V+15=+15.0
V+7.5=+7.8
V+5=+5.0
V-5=-5.0
RF_PS1=09.9
RF_PS2=10.0
TEMP1=+09.0
TEMP2=-10.0
LTEMP=+10.0
FWPWR=029.0
RVPWR=<12.0
REFVT=+04.3
If it is not applicable, it will display xx.x – Example: TEMP2=xxx.x
RMS?
RMS=x….x
(see Description of
Arguments)
Содержание KPA series
Страница 20: ...Ku Band Solid State Power Amplifier Revision 1 Introduction MN KPA IOM 1 4 Figure 1 3 KPA 080 100 Block Diagram...
Страница 30: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Installation MN KPA IOM 2 4 Notes...
Страница 84: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix A MN KPA IOM A 6 Notes...
Страница 124: ...KPA Ku Band Indoor Solid State Power Amplifier Revision 1 Appendix C MN KPA IOM C 30 Notes...
Страница 126: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...