DT4572 X-Band Down Converter
Rev. 0
Remote Control
MM/DT4572.IOM
61
B.6.3.3 B
ACKUP
M
ODE
This command allows the user to force a backup condition for maintenance and test
purposes. This command must be sent to the converter designated as the backup
Converter (i.e., “BU”). When activated this command forces the backup Converter to
assume the state of the specified chain converter and forces the chain converter offline.
Command
Details
Initiate a Backup:
<DEV/FBU_xx_y'cr'
Confirmation: >DEV/FBU
_
xx_y'cr''lf']
Where: xx = 01 to 12, converter number
y = ‘F’ to force a backup ‘N’ to remove a backup
Retrieve Backup
Status:
<DEV/FBU
_
'cr'
Confirmation: >DEV/FBU_xx_zzzzz'cr''lf']
Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter
number is not displayed.
zzzzz = ‘NONE’ if no backup active
= ‘ACTIVE’ if an automatic backup has occurred
= ‘FORCED’ if a forced backup is active
B.6.4 S
TATUS
C
OMMANDS
Status commands retrieve configuration, maintenance and alarm status in summary form.
B.6.4.1 C
ONFIGURATION
S
TATUS
Command
Details
Configuration Status:
<DEV/RCS_'cr'
Confirmation: >DEV/RCS_'cr'
FRE_xxxxx.xxx'cr'
Frequency
ATT_yy.yy'cr'
Attenuator
TX_nnn'cr'
Transmitter
-
ON/OFF/COLD
ONL_nnn'cr'
Online
-
ON/OFF
RED_xx_yy_z'cr' See
Note
CLD_nnn'cr'
Cold Start - ON/OFF
AFR_nnn'cr'
Auto
Flt
Recovery-ON/OFF
EXT_xxx'cr''lf']
Ext. Ref. - YES/NO
Note:
If Redundancy OFF, xx_yy_z = OFF. If Redundancy ON and converter selected as
backup controller, xx_yy_z = BU_yy where yy is the number of converters in the chain
(i.e. 01 to 12). If Redundancy ON and converter is selected as a chain unit xx is the
converter number (01 to 12), yy = P1 or P2 for single or dual polarity system, and z = A if
Auto Mode or M if Manual Mode.
Содержание DT-4572
Страница 1: ...DT 4572 X Band Down Converter Installation and Operation Manual Part Number MN DT4572 IOM Rev 0 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Страница 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Страница 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Страница 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Страница 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...