DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Front and Rear Panel Connectors
Revision 2
4–10
4.2.1.2
Power Interface Module – Optional -48VDC Unit
Figure 4-10. Optional DC Power Module
, the DC power interface module consists
of the following components:
Item 1 – Power Connection
This is a standard 2
-
circuit terminal block. Note the following:
•
Input power – 75W maximum, less than 65W typical.
•
Input voltage – 36-72VDC.
Item 2 – Press-fit Fuse Holder
Install two 3.15A 20mm Slo-Blo type fuses into this fuse holder, one each for line
and neutral fusing.
Item 3 – Power Switch
Use this switch to apply power to the unit.
4.2.1.2.1
DC Operation – Replace the Fuses
WARNING!
DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!
CAUTION
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES
WITH THE CORRECT TYPE AND RATING.
Do these steps to replace the DC fuses:
1.
Disconnect the power supply leads.
2.
Pry the fuse holder outward from the DC power supply module.
3.
Remove and replace the 3.15A 20 mm Slo-Blo fuses as needed.
4.
Press fit the fuse holder back into its receptacle.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...