background image

CRS-170 1:1 Redundancy Switch 

Revision 1 

Installation and Operations Manual 

MN/CRS170.IOM 

22 

2.4 

 

 

Cabling with SDM-300L3 and SMS-301 

 

Figure 3 shows how to connect a pair of SDM-300L3 Modems together with the 
SMS-301 and CRS-170 switches. The same configuration applies to SNM-1001L 
and SNM-1010L. 

 

The following table lists cable assemblies that may be supplied with the CRS-170 
when used with the SDM-300L3 and SMS-301. The other cables between the 
SMS-301 and the SDM-300L3 are the same cables supplied with the SMS-301 in 
an SDM-300A application. 
 

Quantity  Part # 

Description 

CA/WR10163-1  SMS-301 to CRS-170 Control, DB15 Male to DB9 Male 4 ft 

 CA/6357-2 

IF Coax Cable, 50

, length = 2 feet  

 

 

 

 

 

 

 

 

 

 

 

Figure 3. Connection Diagram, SDM-300L3 and SMS-301 

IMPORTANT

 

When connecting the Control cable between the CRS-170 and the SMS-301, 
ensure that screw locks on the ‘D’ type connectors are securely fastened. 
This will prevent the accidental un-mating of the cable, particularly when a 
standby unit is being removed or replaced. 

 

SDM -300L3

SDM

-

300L3

SDM -300L3

SDM

-

300L3

CRS -170

CRS

-

170

Tx 

(Note 1)

Rx 

(Note 2)

Tx 

(Note 1)

Rx 

(Note 2)

Notes: 
1.

 

Includes Tx L -Band, BUC DC, 10 MHz and FSK

2.

 

Includes Rx L -Band, LNB DC, 10 MHz

Tx 

 

L

 

-

 

Band

 

BUC DC

 

10 MHz

 

FSK

 

Rx 

 

L

 

-

 

Band

 

LNB DC

 

10 MHz

 

User

 

Data

 

Interface

 

1:1 Control

SMS

 

-

 

301

 

SMS

 

-

 

301

 

Data

Data

J2 A

 

J3 B

 

J5
Tx A

J6
Tx B

J1
Rx A

J2
Rx B

J8

J7

J3 (Top)

J14

 

Modem A

Modem B

CP1

CP3

CP1

CP3

J8

J8

J1

 

Содержание CRS-170

Страница 1: ...Part Number MN CRS170 IOM Revision 1 CRS 170 1 1 Redundancy Switch Accessory Product for use only with Comtech EF Data CDM 600L and SDM 300L3 Modems Modem Firmware and Hardware Requirements Apply...

Страница 2: ......

Страница 3: ...Accessory Product for use only with Comtech EF Data CDM 600L and SDM 300L3 Modems Modem Firmware and Hardware Requirements Apply Part Number MN CRS170 IOM Revision 1 October 4 2004 Comtech EF Data is...

Страница 4: ...Number 480 333 4357 Customer Support Desk Fax 480 333 2161 To return a Comtech EF Data product in warranty and out of warranty for repair or replacement 1 Request a Return Material Authorization RMA n...

Страница 5: ...nd SMS 301 22 CHAPTER 3 FUNCTIONAL DESCRIPTION 23 3 1 Operation with CDM 600L and CRS 150 24 3 2 Operation with SDM 300L3 and SMS 301 25 CHAPTER 4 CONNECTOR PINOUTS 27 4 1 Modem Side Connectors 27 4 1...

Страница 6: ...DM 600L and CRS 150 21 Figure 3 Connection Diagram SDM 300L3 and SMS 301 22 Figure 4 Modem Side of Module 27 Figure 5 Antenna Side Connectors and Ground Lug 31 Tables Table 1 CRS 170 Application Summa...

Страница 7: ...AND REFERENCES CAUTIONS AND WARNINGS IMPORTANT Indicates information critical for proper equipment function WARNING Indicates a potentially hazardous situation that if not avoided could result in dea...

Страница 8: ...continues to comply with these standards observe the following instructions Connections to the transmit and receive IF ports BNC female connectors should be made using a good quality coaxial cable fo...

Страница 9: ...as a condition of manufacturing on all units to ensure compliance with safety requirements of EN60950 The equipment is rated for operation at 12 volts DC and 12 volts DC It has a maximum power consum...

Страница 10: ...ch vehicles do not provide a stable environment safety of the equipment to EN60950 may not be guaranteed TELECOMMUNICATIONS TERMINAL EQUIPMENT DIRECTIVE In accordance with the Telecommunications Termi...

Страница 11: ...eturn to Comtech EF Data No other warranty is expressed or implied Comtech EF Data specifically disclaims the implied warranties of merchantability and fitness for particular purpose EXCLUSIVE REMEDIE...

Страница 12: ...___ ________________________________________________________________________ ________________________________________________________________________ __________________________________________________...

Страница 13: ...and transmit RF 10 MHz BUC frequency reference 600 KHz BUC FSK control and status communication BUC DC power supply The receive side of the switch uses both power dividers and relays to provide the re...

Страница 14: ...er to the CRS 170 through the CRS 150 The SMS 301 itself has redundant power supplies and feeds power to the CRS 170 through the control cable Online standby modem configuration matching is provided b...

Страница 15: ...600L CRS 170 CRS 150 Firmware 1 1 4 or higher Hardware Rev 3 or higher SDM 300L3 CRS 170 SMS 301 L Band version of SMS 301 SNM 1001L CRS 170 SMS 301 L Band version of SMS 301 Refer to SDM 300L3 SNM 1...

Страница 16: ..._____________________________________________________________________ ______________________________________________________________________________ ___________________________________________________...

Страница 17: ...pping containers are damaged they should be kept until the contents of the shipment have been carefully inspected and checked for normal operation Remove the packing list from the outside of the shipp...

Страница 18: ...mall size and weight one installation option is to let the module hang freely supported by the interfacing cables Alternatively a rack mounting kit KT 10254 is available that allows the module to be m...

Страница 19: ...ble DB25 Male to Male 4 ft DB9 Male 1 ft 4 CA 6357 2 IF Coax Cable 50 length 2 feet IMPORTANT When connecting the Control cable between the CRS 170 and the modems ensure that screw locks on the D type...

Страница 20: ...CRS 170 Control DB15 Male to DB9 Male 4 ft 4 CA 6357 2 IF Coax Cable 50 length 2 feet Figure 3 Connection Diagram SDM 300L3 and SMS 301 IMPORTANT When connecting the Control cable between the CRS 170...

Страница 21: ...and LNB interface signals that are multiplexed onto the transmit and receive coaxial cables Tx and Rx L Band signals 10 MHz reference to BUC and LNB DC Power to BUC and LNB FSK signaling to the BUC O...

Страница 22: ...olts DC at a combined total of 120 mA max Maximum power consumption occurs in a serial LVDS mode at maximum data rate 20 Mbps Power consumption in EIA 232 modes is approximately 40 of the maximum valu...

Страница 23: ...s are removed since the connectors and internal switching are not suitable for L Band operation Signals on the Status Faults connector J14 are modified to provide 12VDC power output and A B switch con...

Страница 24: ..._______________________________________ ________________________________________________________________________ ________________________________________________________________________ ______________...

Страница 25: ...SDM 300L3 SMS 301 Name Ref Des Connector Type Function RX A J1 Type N RF Input to Modem A RX B J2 Type N RF Input to Modem B TX A J5 Type N RF Output from Modem A TX B J6 Type N RF Output from Modem...

Страница 26: ...6 7 and 8 loop the same signals from Modem A through to Modem B The 12VDC input which is diode OR ed with the corresponding 12VDC input from modem B powers the switch module Table 2 J3A Modem A Contro...

Страница 27: ...6 7 and 8 loop the same signals from Modem B through to Modem A The 12VDC input which is diode OR ed with the corresponding 12VDC input from modem A powers the switch module Table 3 J3B Modem B Contro...

Страница 28: ...he L Band Switch Module Refer to Table 4 for details Table 4 Modem Side Type N Connectors Type N Connector Reference Description Direction RX A J1 RX IF signal LNB 10 MHz Ref LNB Power Out In In RX B...

Страница 29: ...de of the CRS 170 L Band Switch Module provide the coaxial cable connections to the outdoor transmit and receive equipment BUC and LNB Refer to Figure 5 Type N Connector Reference Function Direction R...

Страница 30: ..._______________________________________ ________________________________________________________________________ ________________________________________________________________________ ______________...

Страница 31: ...signal fed to both Online and Standby units Rx switching supports all LNB interface signals RF 10 MHz reference and power supply Switch Conditions Tx Rx switching follows state of supporting data swi...

Страница 32: ...0 8kg Dimensions 1 75 H x 8 2 W x 5 3 inches 44 5H x 208 2W x 134 6 D mm excluding connectors 19 inch rack mounting kit available Power requirements 1 5 Watts maximum 12 volts DC 120 mA max Power sup...

Страница 33: ...103 1 609 x 103 1 609 1 mm 0 03937 1 kilometer 0 621 Temperature Conversions Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoir Pound Troy Kilogram 1 gram 0 03527 0 03215 0 002205 0 0...

Страница 34: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...