CDM-600L Satellite Modem Revision 0
BUC FSK Communications MN/CDM600L.IOM
16–2
Note:
If the BUC does not respond within the maximum response time the IDU should
cyclically repeat the command.
On power-up, the Tx carrier is Off until the BUC is commanded to turn the carrier on
(unless the unit is commanded into the power On mode at the factory). The BUC does not
allow the carrier to be turned On unless the PLL is locked, and automatically turns the
carrier Off in the event the PLL goes out-of-lock. If the PLL then comes back into lock,
the BUC restores the carrier to the most recent requested state by the IDU. The carrier
enable/disable function is implemented by switching On/Off the switched regulators of the
BUC amplifier chains (a “sleep mode”).
The BUC is equipped with a calibrated power sensor for measuring the power
delivered to the antenna for rated output to 20 dB backed off. This value, in dBm,
is available via the M&C for power level monitoring and AGC.
Refer to BUC manufacturer specifications for reported power accuracy.
16.1.1 Transmission
Interface
Each transmitted data packet consists of 7 bytes of information. The BUC only
accepts a command if the first data byte contains the appropriate address.
Commands are only executed if the checksum coincides, but a status response is
sent if the address is correct and the command number is within the valid range.
16.2
Message Structure
16.2.1
Command Message Structure (CDM-600L to BUC)
Byte
Name
Description
Value
1
Address
Address of BUC
0x01 to 0x0f
2 Command
Request
Status
Tx On/Off
Change Address
Set Carrier Frequency
0x01
0x02
0x03
0x04
3
Data Byte 1
Not used if command:
= 0x01
Tx control if command:
= 0x02
New address if command:
= 0x03
Carrier Frequency if command:
= 0x04
0xAA
0=Off, 1=On
0x01 to 0x0f
MSbyte
4
Data Byte 2
Not used if command:
= 0x01
Not used if command:
= 0x02
Not used if command:
= 0x03
Carrier Frequency if command:
= 0x04
0XAA
0xAA
0xAA
LSbyte
5
Data Byte 3
Not Used
0xAA
6
Data Byte 4
Not Used
0xAA
7
Checksum
Algebraic sum of bytes 1 - 6
Содержание CDM-600L
Страница 2: ......
Страница 4: ......
Страница 6: ...CDM 600L Satellite Modem Revision 0 Preface MN CDM600L IOM ii This page is intentionally blank ...
Страница 74: ...CDM 600L Satellite Modem Revision 0 Front Panel Operation MN CDM600L IOM 6 28 Figure 6 4 Loopback Modes ...
Страница 122: ...CDM 600L Satellite Modem Revision 0 Open Network Operations MN CDM600L IOM 9 6 This page is intentionally blank ...
Страница 126: ...CDM 600L Satellite Modem Revision 0 Clock Modes and Drop and Insert D I MN CDM600L IOM 10 4 Figure 10 1 Tx Clock Modes ...
Страница 127: ...CDM 600L Satellite Modem Revision 0 Clock Modes and Drop and Insert D I MN CDM600L IOM 10 5 Figure 10 2 Rx Clock Modes ...
Страница 134: ...CDM 600L Satellite Modem Revision 0 EDMAC Channel MN CDM600L IOM 11 4 This page is intentionally blank ...
Страница 159: ...CDM 600L Satellite Modem Revision 0 Remote Control MN CDM600L IOM 15 7 This page is intentionally left blank ...
Страница 194: ...CDM 600L Satellite Modem Revision 0 BUC FSK Communications MN CDM600L IOM 16 6 This page is intentionally left blank ...
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...