COMPX RegulatoR Скачать руководство пользователя страница 10

 

 

 RegulatoR

®

, Keyless Locking   10 

Changing the User Code 
To change the user code, follow the steps on page 9 to enter programming mode. 
 
The factory default user code is 1234 (User codes must be 4 to 8 digits in 
length.)  
 
There is a 10 second programming time limit between each step. If RegulatoR 
times out or an error is made, programming will end and you will need to enter 
programming mode again. 
 
 

1.

 

Place RegulatoR into programming mode (see page 9). 

2.

 

Press 1 and then press ENTER

3.

 

Type the current user code and press ENTER

4.

 

Type the new user code and press ENTER

5.

 

Retype the new user code and press ENTER.  

6.

 

If successful, the green indicator light will illuminate for 1 second. 

 
Continue programming or press 9 and then ENTER to exit programming. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание RegulatoR

Страница 1: ...0 RegulatoR Keyless Locking 1 Instruction Manual ...

Страница 2: ...de Operation is simple type a valid code and press ENTER Then just turn the lever to the locked or unlocked position RegulatoR is easy to install and offers Programmable user and supervisor codes Programmable modes of operation Programmable reset features RegulatoR is intended for interior use only Operating Temperature 50 F 120 F 10 C 48 C Note It is strongly recommended that batteries be replace...

Страница 3: ...ring SlamCAM 2 AAA alkaline batteries SlamCAM spacer discs Mounting hardware Each lock contains 2 green stickers that are needed for resetting RegulatoR In the event RegulatoR needs to be reset one green sticker is placed on the back of the device The remaining green sticker should be saved in a safe and secure location for future reference See page 11 for reset instructions Care and Cleaning To c...

Страница 4: ...ng Introduction 6 Programming Mode 9 Changing the User Code 10 Changing the Supervisor Code 11 Single Use Standard Mode 12 Single Use Timeout ON OFF 13 Security Timeout ON OFF 14 Reset User Code 15 Technician Mode 16 User Slot 03 20 Programming 18 Mounting Template 22 Part Number Descriptions 23 ...

Страница 5: ... different chemistries could damage the RegulatoR resulting in lock failure To power up RegulatoR remove the red tag Lock is now ready for use A T 15 pin in head Torx 6 lobe will be required to remove the battery cover Not Included To change batteries 1 Loosen the retaining screw 2 Remove battery cover 3 Press CLEAR 5 times 4 Insert new batteries as shown in the illustration 5 Reinstall battery co...

Страница 6: ...omplete programming instructions prior to making any changes Remember to keep track of any programming changes Button locations indicator lights and knob referenced in the programming instructions are shown below CLEAR button erases any key input made in error Indicator Lights Green Indicates button input and valid code Yellow Indicates low battery or program mode Red Indicates incorrect entry Kno...

Страница 7: ...sion follow the directions below to unlock and lock the RegulatoR To operate the standard Self Lock version of RegulatoR Type a valid code press ENTER and rotate knob clockwise 90 hold knob until door or drawer is open Release knob RegulatoR knob will return to the locked position Door or drawer can be closed at any time ...

Страница 8: ...ersion If your lock is the Manual Lock version follow the directions below to unlock and lock the RegulatoR To operate the standard Manual Lock version of RegulatoR To unlock type a valid code press ENTER and rotate knob clockwise 90 To lock rotate knob 90 counter clockwise ...

Страница 9: ...ep If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Lock must be in the locked position prior to entering programming mode 2 Type supervisor code and press ENTER Rotate the knob to the unlocked position and press and hold ENTER for 3 seconds yellow indicator light will illuminate If product is Self Lock with the SlamCAM feature you...

Страница 10: ... step If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 2 Press 1 and then press ENTER 3 Type the current user code and press ENTER 4 Type the new user code and press ENTER 5 Retype the new user code and press ENTER 6 If successful the green indicator light will illuminate for 1 secon...

Страница 11: ... new supervisor code and press ENTER 5 Retype the new supervisor code and press ENTER 6 If successful the green indicator light will illuminate for 1 second Continue programming or press 9 and then ENTER to exit programming RegulatoR features a reset code which will restore the default supervisor code and user code RegulatoR was shipped with reset stickers one attached to the back of the RegulatoR...

Страница 12: ... Standard Mode follow the steps on page 9 to enter programming mode There is a 10 second programming time limit between each step If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 a To turn Single Use Mode ON type 51 and then press ENTER OR b To return to Standard Mode type 50 and the...

Страница 13: ... RegulatoR to Single Use Timeout ON or OFF follow the steps on page 9 to enter programming mode There is a 10 second programming time limit between each step If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 a To set Timeout ON type 2XX and then press ENTER XX represents a time period...

Страница 14: ...N or OFF follow the steps on page 9 to enter programming mode There is a 10 second programming time limit between each step If RegulatoR times out or error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 a To turn Security Timeout ON type 11 and then press ENTER OR b To turn Security Timeout OFF type 10 and then pres...

Страница 15: ...e There is a 10 second programming time limit between each step If RegulatoR times out or error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 2 Type 8888 and then press the ENTER button 3 If successful the green indicator light will illuminate for 1 second Continue programming or press 9 and then ENTER to exit prog...

Страница 16: ... times out or error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 2 To turn Technician Mode ON type 31 and then press ENTER 3 Type the desired 4 to 8 digit Technician Code and then press ENTER 4 Retype Technician Code and then press ENTER 5 REMEMBER THIS CODE OR To turn Technician Mode OFF type 30 and then press EN...

Страница 17: ...to the unlocked position all three LED lights will have a rotating blinking pattern 3 To relock retain the single use code that already exists rotate the knob 90 counter clockwise OR To remove the existing single use code and leave the RegulatoR unlocked Type the Technician Code and press ENTER Press 1 then press hold CLEAR for 3 seconds ...

Страница 18: ...ength and must be different from all existing codes including Slot 01 Supervisor Slot 02 User codes There is a 10 second programming time limit between each step If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 2 Press 410 and then press ENTER 3 Type the new user code and press ENTER...

Страница 19: ...02 User codes There is a 10 second programming time limit between each step If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 2 Press 411 and then press ENTER 3 Type memory slot to be added followed by ENTER for memory slots 03 09 you must type leading 0 e g 07 for slot 7 4 Retype mem...

Страница 20: ...o enter programming mode There is a 10 second programming time limit between each step If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 2 Press 400 and then press ENTER 3 Type the user code to be deleted and press ENTER 4 Retype the user code to be deleted and press ENTER 5 If succes...

Страница 21: ... 10 second programming time limit between each step If RegulatoR times out or an error is made programming will end and you will need to enter programming mode again 1 Place RegulatoR into programming mode see page 9 2 Press 401 and then press ENTER 3 Type memory slot to be vacated followed by ENTER for memory slots 03 09 you must type leading 0 e g 07 for slot 7 4 Retype memory slot to be vacated...

Страница 22: ...RegulatoR Keyless Locking 22 ...

Страница 23: ...R Right hand mount door application hinge on right side when facing cabinet V Vertical mount door application keypad located above locking point T Top vertical mount door application keypad located below locking point Cylinder Length 1 7 16 cylinder length 3 1 3 16 cylinder length 5 1 3 4 cylinder length Color BK Matte black housing knob No suffix Standard silver housing knob Replacement Parts REG...

Страница 24: ...pped can be inserted between the lock barrel and SlamCAM mechanism to adjust the backset See image below FlexaCam adaptors if so equipped can be attached to the cam to provide up to 12 different dimensional variations See image below Rev E 08 15 PN 333153000000 ...

Отзывы: