MENU – SYSTEM (continued) 

 TP4MD/CD / TP10MD/CD / TP16MD/CD 

15

 

E

N

G

L

IS

H

 

Lock  menu

  –  using  this  function,  menu  is  locked.  If 

the user password was set up, the system will ask you 
for  setting  up  the  entrance  password  during  another 
try  of  access.  If  the  install password was set up, this 
choice will lock all install menus. To unlock them it is 
possible  only  with  the  help  of  the  function 

Unlock 

locked menus

. The item 

Lock menu

 is not available in 

the  case  that  no  password  has  been  set  up  or  the 
menu has been already locked. 

 
Unlock locked menus

 – after choosing this item and 

setting the correct install password, the install menus 
will  be unlocked. This choice is blocked, if the install 
password  has  been  disabled  or  the  menus  are 
unlocked already. 
 

Change user password

 – enables to set up a new or 

disabled  the  old  user  password.  Setting  an  empty 
password disables the password. 
 

 
 
 
 
 
 
 
 
 

 

Change install password

 – enables to set a new or 

disable  the  old  install  password.  Setting  an  empty 
password  disables  the  password.  If  the  menu  is  not 
available,  it  is  necessary  to  unlock  the  menu  in  the 
menu 

Unlock  locked  menus

  by  typing  the  install 

password. 
 

TIME AND DATE 

This  menu  enables  the  possibility  of  changing  the 
topical time and date of the multiplexer and its format 
of displaying on the monitor. If you choose some time 
and  date  item,  time  will  stop  and  will  not  start  since 
this menu is finished. 
 

 
 
 
 
 
 
 
 
 
 

 

TIME CORRECTION 

You  can  correct  the  multiplexer  internal  clock  devia-
tions  by  setting the value of seconds added or taken 
off per a day. For example: If the clock of multiplexers 
delays  2.5  seconds  a  day,  increase  the  value  of  the 
correction of 2.5 s, if it speeds up decrease of 2.5 s. 
 

FORMAT 

Choose the displaying format of time and date on the 
screen. 
 

 
 
 
 
 
 
 
 
 

 

LANGUAGE 

Choose the language for communication with user. 

 

 
 
 
 
 
 
 
 
 
 

 

DISPLAY 

Choose whether to display camera titles and the date 
and  time  on  the  status  line  in  LIVE  mode  and  re-
cording. Then you can set-up the interlace correction. 
The  interlace  correction  influences  the  displaying  of 
the cameras on the monitor and the recording. 

 

 
 
 
 
 
 
 
 
 
 

 

Disabled interlace correction of live images can cause 
the  gliding  effect  of  reduced-size  pictures,  which  is 
caused by the displaying of different fields of the same 
camera. The same field will be displayed by marking 
this item. The picture stability increases with result of 
slower displaying. 
The interlace correction of record always ensures the 
recording of same fields of the camera. The playback 
quality  will  be  higher,  but  it  can  result  the  lower  fre-
quency  of  recorded  cameras  switching.  This  choice 
will affect only the recording to the VCR in the minimal 
mode (3 hours). 

 

Содержание TP10CD

Страница 1: ...ENGLISH BLACK WHITE AND COLOUR MULTIPLEXERS Installation and user manual TP4MD TP10MD TP16MD TP4CD TP10CD TP16CD ...

Страница 2: ......

Страница 3: ...CAN RS 485 RS 232 INTERFACE 4 EXTERNAL KEYBOARD 4 MULTIPLEXER NETWORKING 4 MULTIPLEXER CONTROLLING 5 CAMERA DISPLAYING LIVE 5 PLAYBACK PLAY 5 DIGITAL ZOOM ZOOM 5 PICTURE RECORDING REC 5 ANALOGUE CHANNEL CONTROLL SEQ 5 DISPLAYING VCR INPUT VCR 5 SELECT VIEW VIEW 5 TELEMETRY CONTROLLING 5 FREEZE PICTURE HOLD 6 LOAD MACRO MACRO 6 ALARM STATUS ALARM 6 LIST OF EVENTS 6 MENU 7 MAIN MENU 7 VIDEORECORDER ...

Страница 4: ...tching The spot channel is used even for manual controlling from the main panel o 4 10 or 16 video inputs o main and spot output o VCR input and output o automatic TV standard detection from connected cameras o 864 samples per a TV line CCIR PAL 856 EIA NTSC o 576 active TV lines CCIR PAL 480 EIA NTSC o 256 grey scale 16 million colours o RS 485 and CAN interface for telemetry control ling of pan ...

Страница 5: ...tions 16 IN1 IN16 Video inputs for cameras 1 16 The video inputs are automatically terminated if the corresponding video output is left unconnected If a device is connected to video out make sure that it is properly terminated 17 VCR IN Use this video input for connecting from VCR 18 SPOT Video output to spot monitor 19 OUT1 OUT16 Video outputs for cameras 1 16 20 VCR OUT Video output to VCR 21 MA...

Страница 6: ...cted to the CAN bus You can connect several external keyboards to CAN bus and control different or the same devices During controlling of one device by several keyboards you are able to operate controlled device by another key board five seconds after the last command of the pre vious keyboard it is not possible to control one device from two keyboards at the same time MULTIPLEXERS NETWORKING Usin...

Страница 7: ... channel is switched on by pressing the button SEQ The buttons 1 to 16 are used for displaying a corresponding camera by press ing the button AUTO it is switched the automatic switching sequence on or off Set up sequential switching parameters using the menu Sequence Cameras in sequence and Time multiplier see page 8 and 9 By another pressing the button SEQ the mul tiplexer switches back into the ...

Страница 8: ...er leaving the cameras menu and pressing the PRESET button you return back to the pan tilt and lens controlling mode After that the PRESET disa pears from the status line FREEZE PICTURE HOLD During LIVE and PLAY modes pressing the button HOLD freezes the main channel monitor view The picture starts to move again by other pressing of this LOAD MACRO MACRO TP multiplexers enable to define so called ...

Страница 9: ...nction it is important to ensure that the VCR and multiplexer work in the same mode You can also define the type of the con nection between the VCR and the multiplexer with the help of AUX input VCR TYPE Set up your VCR type here If your VCR type is not mentioned here use an analogous type or choose a user defined VCR and set up the working VCR modes in the menu User defined VCR see page 7 VCR MOD...

Страница 10: ...CR and the multiplexer If the operator switches the recording speed on the VCR or the recording speed is changed by the influence of the alarm signal on the VCR the multiplexer changes its recording speed automatically Start record if the AUX input activity is detected multiplexer starts the recording automatically MENU CAMERA Set up camera parameters of recording displaying activity detection seq...

Страница 11: ...rameter TIME MULTIPLIER The time of the displaying of particular cameras can be quite lengthened or shortened and the proportion of displaying particular steps cameras still lasts It is important to note that the time of displaying one step after the change will still stay in interval of 1 to 255 seconds There is an illustrated example in the table how the switching time changes according to the p...

Страница 12: ...m inputs marking the line the alarm inputs will influence recording Activity detector if you mark this line the activity detector will influence recording Alarmed cameras only only the cameras with the alarm detection will be recorded during the alarm las ting The source of the alarm can be either from the alarm inputs or from the activity detector Selected alarmed cameras only only the cameras wi...

Страница 13: ...functions below than have no meaning No reaction to alarm no reaction to alarm inputs Follow input active during the alarm lasting on any of the inputs Switch on XX seconds active for the time from 1 to 99 seconds since the last alarm activation No reaction to camera fail no reaction to the video signal lost Switch on XX seconds active for the time from 1 to 99 seconds since the camera signal fail...

Страница 14: ...ctor will explore the image changes can be defined with the help of this matrix 18 x 9 of light sensitivity elements for every camera The transparent squares represent active fields There are described controlling buttons for editing the light sensitivity matrix here 1 sets one active matrix field 2 clears one field 3 sets the whole line 4 clears the whole line WALK TEST The walk test is used for ...

Страница 15: ...ded cameras will be changed after the macro is launched Select cameras by opening this submenu you can choose your own set of the cameras for recording Activity detector by marking this line the cameras for activity detection will be changed after the macro is launched Select cameras your own set of the cameras for activity detection Sensitivity of the detector by marking this line the sensitivity...

Страница 16: ...ist of events which corresponds to previous setting in this menu CLEAR LIST You can clear the list of events in this menu by pres sing the button 1 MENU SYSTEM In this menu you can set up such parameters which correspond to the functions of multiplexers as the password the data and time setting interlace correc tion telemetry characteristics and the language choice PASSWORD The user can control th...

Страница 17: ... the multiplexer and its format of displaying on the monitor If you choose some time and date item time will stop and will not start since this menu is finished TIME CORRECTION You can correct the multiplexer internal clock devia tions by setting the value of seconds added or taken off per a day For example If the clock of multiplexers delays 2 5 seconds a day increase the value of the correction ...

Страница 18: ...ess can be set up here Parameters setup parameters for selected protocol The following menus control the function of user out puts AUX1 AUX2 see Telemetry controlling on page 8 Change output by pressing one of the buttons AUX1 2 the state of user output will be changed Follow key The user output is switched on while holding the button AUX ENABLE EXTERNAL KEYBOARD marking this line you enable multi...

Страница 19: ...mination at the end of the line by the connected device or must be left unconnected Cameras on divided screen are slightly shaking Interlace correction is switched off oSet up the interlace correction of live picture in menu SYSTEM DISPLAY page 16 The shaking stops with result of slower displaying At colour multiplexer displayed have incorrect colours Improper setting of camera parameters oCheck t...

Страница 20: ...of the alarm inputs is defective oCheck the connection of the alarm inputs page 3 The device reacts to alarm inputs incorrectly The set up of alarm inputs polarity is incorrect oCheck the polarity of alarm inputs in menu ALARM INPUTS page 10 The alarm output relay does not react properly The polarity of alarm is set up incorrectly oSet up the normal state of alarm output in menu RELAY CONTACTS pag...

Страница 21: ...pin female connector AUX INPUT Loop connection input ground GND Activity programmable Maximum alarm loop impedance 1 kW ALARM OUTPUT Number 1 potentialless contacts of low voltage relay Maximum switching voltage 40 V Maximum switching current 0 5 A RS 485 INTERFACE Baud rate depend on protocol Maximum length 1000 m Terminators 120 W at both ends CAN INTERFACE Baud rate 50 kBs Maximum length bus st...