background image

 

 

Sentinel 150P series 

Programmable, automatic switch mode battery chargers 

Installation, Operation and Maintenance 

This Manual Refers to the Following Models 

 

 

 

Open 

frame 

models  

SNTL150P1205CD 
SNTL150P2405CD 
SNTL150P1205CDA 
SNTL150P2405CDA 

 

 

 

 

For safe and correct use of these chargers, read and save the safety 
information that precedes the installation and operation instructions.  

This guide contains 8 pages (including this one). If any pages are missing, 
contact the battery charger supplier or manufacturer for replacement 
documentation. 

 
 

 

 

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.  

Computronic Controls products and the Computronic Controls logo are registered and/or common law trademarks of Enovation Controls LLC.  

This document, including textual matter and illustrations, is copyright protected by Enovation Controls Ltd., with all rights reserved. © 2014 Enovation Controls Ltd.

 

 

 

41 – 46 Railway Terrace, Nechells,  
Birmingham, B7 5NG, United Kingdom 
Web: www.computroniccontrols.com

 

For sales & support, contact: 

 

ENOVATION CONTROLS LTD. 

Church Road, Laverstock,  
Salisbury, SP1 1QZ, United Kingdom 

Phone: +44 1722 410055 
Fax: +44 1722 410088 
E-mail: [email protected] 
Web: www.computroniccontrols.com 

          www.fwmurphy.eu/computronic 

ENOVATION CONTROLS 

5311 S 122nd East Avenue,  
Tulsa, OK 74146, USA

  

Phone: +1 918 317 4100 
Fax: +1 918 317 4266 
E-mail: [email protected] 
Web: www.fwmurphy.com 

 

Содержание Sentinel 150P series

Страница 1: ...change our specifications and designs at any time Computronic Controls products and the Computronic Controls logo are registered and or common law trademarks of Enovation Controls LLC This document i...

Страница 2: ...and damage to property ix DANGER OF EXPLOSION NEVER CHARGE A FROZEN BATTERY PRIOR TO INSTALLATION COMMISSIONING Clean battery terminals Be careful to keep corrosion from coming into contact with eyes...

Страница 3: ...cover for surface mounting in an enclosed panel Electrical connection of the AC supply battery and control circuits is via screw terminal blocks Model options Model codes with suffix A SNTL150P CDA ad...

Страница 4: ...y block for connection of the DC charge output temperature compensation remote sensor relay output and configurable input Use a 5 mm 0 2 in flat head screwdriver to tighten loosen the terminals For th...

Страница 5: ...uffix A models SNTL150P CDA additionally include one relay output and one digital switch input The functions of input and output can be configured using the SNTL150P PCSUITE software tool Output The s...

Страница 6: ...AWG or larger wire conductors rated for temperature 90 C 194 F The AC live wiring must incorporate fuse ratings types as indicated on the charger labelling Sentinel PC connection SNTL150P PCCON confi...

Страница 7: ...ease in output voltage It may be initiated automatically on battery low voltage programmable level factory default 12 0V 24 0V automatically on expiry of a time interval since the last AutoBoost progr...

Страница 8: ...Sentinel 150P installation operation maintenance ci0050 p8 8 issue 5 2014 08 26 Fault Finding Warranty and Maintenance Troubleshooting Flowchart...

Отзывы: