3.3. Pump protection function

ATTENTION!

 When using the pump protection function, it is recommended that the part of the heat

-

ing system in which the pump to be controlled is installed has a heating circuit during the heating-free 

period in which the heating medium can flow freely at all times. Otherwise, using the pump protection 

function may damage the pump.

The pump protection function of the pump controller protects the pump from sticking during long pe

-

riods of non-use. When the function is on, the output will turn on every 5 days for 15 seconds if the 

output has not been turned on in the last 5 days. During this time, 

” will appear on the display 

instead of the measured temperature.

To  activate/deactivate  the  pump  protection  function,  first  switch  off  the  appliance  by  pressing  the   

button once (the display switches off), then press and hold the

 

 button for 3 seconds. 

POFF

 (factory 

default setting) will appear on the display, indicating that the function is switched OFF. Press

   or    

to change between ON/OFF states. The ON status of the function is indicated by 

”. To save the 

setting and exit the function setting, wait approx. 7 seconds. The device is then switched OFF.

Содержание WPR-100GC

Страница 1: ...COMPUTHERM WPR 100GC Pump controller with wired temperature sensor Operating Instructions...

Страница 2: ...age of 230 V or other electrical appliance within the load capacity limits can be easily controlled The pump controller is responsible for turning the pump on and off at the set and measured temper at...

Страница 3: ...g to set temperature and the switching sensitivity 1 LOCATION OF THE DEVICE It is recommended to place the pump controller near the heat ing cooling pipe or boiler on which the control is based so tha...

Страница 4: ...is displayed when the output of the appliance is switched on Make sure that the wires are properly connected and that that there is no risk of electric shock or short circuit Connect your device as fo...

Страница 5: ...zivatty szivatty vez rl Warning Always take into account the loadability of the controller relay when connecting 10 A 3 Inductive load and follow the instructions of the manufacturer of the pump which...

Страница 6: ...s turned on if the measured temperature is higher than the set temperature The switching sensitivity is taken into account when switching F2 Control of a cooling system s circulating pump the output i...

Страница 7: ...ches the connected pump on off below above the set temperature The lower this value is the more constant the temperature of the circulating fluid will be The switching sensitivity can be set between 0...

Страница 8: ...the function is on the output will turn on every 5 days for 15 seconds if the output has not been turned on in the last 5 days During this time will appear on the display instead of the measured temp...

Страница 9: ...e measured temperature reach es 5 C again to protect the pump and the heating system During this time the display alternates between and the measured temperature When the frost protection function is...

Страница 10: ...itching sensitivity of 1 0 C the pump connected to it switches ON and at temperatures below 39 0 C the output switches OFF the pump connected to it switches OFF In F2 mode the output switches exactly...

Страница 11: ...t accuracy 1 0 C Power supply 230 V AC 50 Hz Output voltage 230 V AC 50 Hz Loadability max 10 A 3 Inductive load Environmental protection IP40 Immersion sleeve connector size G 1 2 8x60 mm Length of h...

Страница 12: ...he requirements of standards EMC 2014 30 EU LVD 2014 35 EU and RoHS 2011 65 EU Manufacturer QUANTRAX Kft H 6726 Szeged F lem le u 34 Telefon 36 62 424 133 Fax 36 62 424 672 E mail iroda quantrax hu We...

Отзывы: