An  example  of  dividing  the  heating  system  into  zones  is  shown  in  the  figure 

below:

From both a comfort and an energy-efficiency point of view, it is recommended 

to activate more than one switch for each day. Furthermore, it is advised that a 

comfort temperature is used only those times, when the room or building is in 

use, since every 1 °C decrease of temperature saves approxi mately 6% energy 

during a heating season. 

2. THE CONNECTION POINTS OF THE ZONE CONTROLLER, 

MOST IMPORTANT TECHNICAL DATA

• 

Each of the 4 heating zones have an associated pair of connection 

points (T1; T2; T3; T4); one for a room thermostat and one for a zone 

valve/pump (Z1; Z2; Z3; Z4).

 The thermostat of the 1st zone (

T1

) controls 

the zone valve/pump of the 1st zone (

Z1

), the thermostat of the 2nd zone 

(

T2

) controls the zone valve/pump of the 2nd zone (

Z2

) etc. 

Following

 

the 

heating

 

command of the thermostats, 230 V AC voltage appears on the 

connection points of the zone valves associated with the thermostats

and the zone valves/pumps connected to these connection points open/start. 

For ease of use, the connection points associated with the same zone have 

the same color (T1-Z1; T2-Z2, etc.).

living room

bedroom 1

bedroom 2

230 V AC

boiler

distributor

manifold

floor h. manifold

floor h. distributor

collector

floor heat. distr.

floor heat. collect.

Содержание Q4Z

Страница 1: ...Operating Instructions zone controller for controlling 1 to 4 heating zones COMPUTHERM Q4Z...

Страница 2: ......

Страница 3: ...h other or in case of need all zones can operate at the same time To control more than 4 zones at a time we recommend using 2 or more COMPUTHERM Q4Z zone controllers 1 zone controller needed per 4 zon...

Страница 4: ...connection points T1 T2 T3 T4 one for a room thermostat and one for a zone valve pump Z1 Z2 Z3 Z4 The thermostat of the 1st zone T1 controls the zone valve pump of the 1st zone Z1 the thermostat of t...

Страница 5: ...reover the four heating zones also have a joint connection point for a zone valve pump Z1 4 If any of the four thermostats T1 T2 T3 and or T4 switches on then beside the 230 V AC voltage appearing at...

Страница 6: ...aratus to be connected to it is connected to the 230 V mains voltage Modifying the device can cause electric shock or product failure Attention We recommend that you design the heating system you want...

Страница 7: ...ats connection points for power supply fix phase working when the power switch is turned on fuse 15 A connection points controlling the boiler connection points of the heating zones In case of using e...

Страница 8: ...lashes with 3 second intervals the LED stops flashing and indicates the current operating mode Automatic Manual Then the working mode can be changed by pressing the A M button again After 10 seconds t...

Страница 9: ...of the thermostats the zone valves pumps associated with the thermostat open start and the boiler also starts also taking the Turn on delay function into account see Section 5 By pressing the A M AUTO...

Страница 10: ...tchable voltage of the relay that controls the boiler 230 V AC 50 Hz Switchable current of the relay that controls the boiler 8 A 2 A inductive load Duration of activable Turn on delay function 4 minu...

Страница 11: ......

Страница 12: ...ves EMC 2014 30 EU LVD 2014 35 EU and RoHS 2011 65 EU Copyright 2020 Quantrax Ltd All rights reserved Manufacturer QUANTRAX Ltd H 6726 Szeged F lem le u 34 Hungary Telefon 36 62 424 133 Fax 36 62 424...

Отзывы: