- 19 -
3.6 Auto-control the socket output by temperature
3.6.1 Over-temperature alarm
Description:
The socket will auto-send the SMS alarm message to
master user and “Beep” if the surrounding temperature is
detected out in the pre-set temperature range or out of the
pre-set temperature range.
Method:
The user sends following SMS message in order to:
Enable over-temperature alarm:
#170#01#
Set in range alarm temperature limit:
#170#1#LowTemp#HighTemp#
Set out of range alarm temperature limit:
#170#0#LowTemp#HighTemp#
Disable over-temperature alarm:
#170#01#
Successful SMS reply
Temperature alert: function ON
Temp: 25C
Mode: In range/Out of range
Min Temp:10C
Max Temp:20C
Mode is the control selection:
For alarm in pre-set temperature range, mode=1. For
alarm out of pre-set temperature range, mode=0.
Temp means temperature value, the range is –10C
to 49C.
Temperature unit is degree Celsius.
Example 1:
set commands: #170#1#20#30# when the
environmental temperature is 21 degrees (in the range of
20-30C in the command) the socket will send SMS alerts
to master user and “beep” until you disable the function.
Example 2:
set commands: #170#0#20#30# when
the environmental temperature is 11 degrees (out of
range of 20-30 in the command) the socket will send
SMS alerts to master user and “beep” until you disa-
ble the function.