SPECIFICATIONS

25654

Capacity

425VA(230W)

Input Voltage on Utility

00V to 40V

Input Frequency

57 Hz to 63 Hz

On-Battery Output Voltage

20Vac ± 5%

Transfer Time

4ms Typical

Max. Load for UPS Outlets (3 
Outlets)

425VA(230W)

Max. Load for Full-Time Surge 
Protection outlets (6 Outlets)

2 Amps

On-Battery Output Wave Form

Simulated Sine Wave Form

Operating Temperature

+ 32°F to 95° F. (0° C to 35° C)

Operating Relative Humidity

0 to 95% NON-CONDENSING

Size (Length x Width x Height)

9 7/8” x 6 3/6” x 3 /8” (25.8cm x 5.9cm x 8.3cm)

Net Weight

0 lbs.

Typical Battery Recharge Time

8 hours typical from total discharge

Typical Battery Life

3 to 6 years, depending on number of discharge/recharge cycles

Battery Type

2V / 4.0AH

Recommended Battery

Spill-proof, Maintenance-free, sealed lead-acid

Safety Approvals

UL778(UPS), CUL07./FCC/DoC Class B

EXPECTED RUNTIME IN MINUTES

25654

Desktop PC with LCD Monitor

-22

Desktop PC with 5” Monitor

8-2

Desktop PC with 7” Monitor

6-9

Model: 25654

425VA/230W UPS Backup System

9

Содержание 25654

Страница 1: ...he outlet and have an electrician check to ensure the outlet is properly wired Circuit Breaker Located on the side of the UPS the circuit breaker serves to provide overload and fault protection Under...

Страница 2: ...outlets DO NOT plug a laser printer copier space heater vacuum or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect...

Страница 3: ...ntrol Panel 6 Double click on Add Remove Programs 7 Click the Install Button and follow the on screen instructions 8 When the installation is completed remove the floppy disk For Windows NT 1 Click on...

Страница 4: ...er in normal When the power fails the indicator will change to a red color with an X through it 7 Battery OK Indicator This indicator appears in a green color when AC power is normal and the unit and...

Страница 5: ...ote The use of the schedule is optional and will have no effect on the shutdown of your system during a power failure This feature is simply used if you want to have your computer automatically shutdo...

Страница 6: ...ure 3 The UPS will begin beeping indicating a power failure 4 Save and close any open files 5 Shut down the operating system 6 Once the computer system is shutdown turn the UPS off As the battery disc...

Страница 7: ...ery power supplied outlets from its battery Off On Off Utility Failure The UPS is providing battery power Rapid beeps indicate the unit will run out of power shortly Off Off System Overload Occurs whe...

Страница 8: ...must be connected to a 110 120v 60Hz outlet The battery is worn out Replace the unit PowerPanel is inactive all icons are gray The serial cable is not connected Connect the serial cable to the UPS un...

Страница 9: ...ative Humidity 0 to 95 NON CONDENSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 25 8cm x 15 9cm x 8 3cm Net Weight 10 lbs Typical Battery Recharge Time 8 hours typical from total discharge T...

Отзывы: