Rev.01 03-27-17
Page 25 of 71
Compu-Aire
5.7
Analog Outputs
The controller features 0-10Vdc and PWM analog outputs without optical isolation, powered directly by
the controller.
Figure 7 Analog outputs
5.8
Digital Outputs
The controller features digital outputs with electromechanical replays. For ease of installation, the
common terminals of some of the relays have been grouped together. Some relays feature changeover
contacts.
5.9
Cable Length
Cable Type
Power Supply Distance
Power Supply
Telephone
50m
150mA from controller
AWG24 shielded cable
200m
150mA from controller
AWG20/22 shielded cable
500m
Separate power via TCONN6J000
The maximum cable length between the two controllers using AWG20/22 shielded cable is 500
meters.
Note:
A maximum of one terminal (pCOT, pCOI, pGD0, pGD1) can be connected, or two
terminals but without using use the backlighting on display. One version of the
controller features optically-isolated connection to the pLAN network.
The graphic terminal and aria terminal should be always powered with a separate
power supply.
The 21VDC present at +Vterm (J24) can be used to power an external terminal
with a maximum input of 2 W. Only one terminal can be connected (for example
PLD terminal or ARIA terminal) in addition to the one connected to terminal J10.