Section 7 

Maintenance and Calibration 

 

WARNING: 

THESE  SERVICE  INSTRUCTIONS  ARE  FOR  USE  BY  QUALIFIED  PERSONNEL  ONLY.    TO  AVOID 
ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE 
OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO. 
 

 

Service Information 

 
The MegaPulse D5-PF tester is warranted to the original purchaser for a period of 1 year.  This warranty does not 
cover problems due to misuse or neglect.  Malfunctions which occur within the limits of the warranty will be corrected 
at no charge.  Mail the instrument postpaid to the manufacturer.  Dated proof of purchase is required for all in-warranty 
repairs.  The manufacturer is also available for calibration and / or repair of instruments that are beyond their warranty 
period.  Contact the manufacturer for a cost quotation.  Ship the instrument and your remittance per the instructions 
given by the manufacturer. 
 

 

General Maintenance 

 

To  avoid  contaminating  the  PWB  with  oil  from  your  fingers,  handle  it  by  the  edges  or  wear  gloves.    If  the  PWB 
becomes contaminated, refer to the cleaning procedures given later in this section 

 

 

Cleaning 

 

CAUTION 

Do  not  use  aromatic  hydrocarbons  or  chlorinated  solvents  for  cleaning.    These  solutions  will  react with the 
plastic materials used in the instrument. 

 
Clean the front panel and case with a mild solution of detergent and a damp sponge. Clean dust from the PWB with 
clean, dry, low pressure (<20 psi). 
 

 

Calibration Information 

 
The  MegaPulse  D5-PF  has  been  fully  calibrated  at  the  factory  in  accordance  to  our  published  specifications.  It  is 
recommended that you have this instrument re-calibrated and safety check done at least once per year. The procedure 
consists on internal components tolerance verification and calibrating the meter reading to agree with the capacitor 
bank.  
 
The Calibration procedure must be performed by qualified personnel. Contact Compliance West USA for the latest 
calibration procedure.  Have ready the serial number of the MegaPulse D5-PF tester. 
 

 

 

 

Содержание MegaPulse D5-PF

Страница 1: ......

Страница 2: ......

Страница 3: ...nd ergonomic front panel and represents the latest in high voltage impulse testing To fully appreciate all the features of your new instrument we suggest that you take a few moments to review this man...

Страница 4: ...eyboard and Voltage Knob Enable 13 Discharging Residual Voltage 13 Polarity Pulse Selection 14 Voltage Set Point Adjustment 14 Charge and Trigger a Pulse 14 Pulse Verification Procedure 15 Energy Meas...

Страница 5: ...iii Cleaning 26 Calibration Information 26 Technical Assistance 27...

Страница 6: ...iv...

Страница 7: ...ical fundamentals clearly and be aware that high voltage is adept and creative at completing a path to ground Instructions should include a warning against any metal jewelry Operators should not allow...

Страница 8: ...test should be connected to the MegaPulse tester and then left alone by the operator After the operator is clear of the Tester and the equipment under test the operator should turn the rear panel pow...

Страница 9: ...re when using the MegaPulse unit Pressing the POLARITY switch on the front panel can change the polarity of the output waveform The polarity is Normal when the NOR indicator is lit In this case the hi...

Страница 10: ...tage Test Lead Red HVLR Qty 3 High Voltage Test Lead Black HVLB Qty 2 High Voltage Jumper Red HVLEC13 Option 100X includes one Jumper and option 34 also includes one Jumper Total Qty 2 if all options...

Страница 11: ...e certified or approved by any recognized national test house are regarded as meeting this requirement Fuse Replacement There is a user replaceable fuse F1 located on the rear panel of the instrument...

Страница 12: ...Set point adjusted by frontal VOLTAGE knob or by PC TestMinder Polarity Control Positive and Negative Alternating control available with optional computer control Voltage Display 4 Digit LED Display V...

Страница 13: ...th the use of its controls indicators and connectors The front panel features of the MegaPulse are shown in Figure 1 and described in Table 1 The rear panel features of the MegaPulse are shown in Figu...

Страница 14: ...rs will be blinking if the Interlock Switch is open 6 TRIGGER switch Triggers the output impulse waveform The impulse waveform will appear across the output leads 7 TRIGGER indicator This red indicato...

Страница 15: ...unded 19 AUX OUTPUT indicator This Green indicator is lit to show that AUX OUPUT switch is set on the FLOAT position 20 S3 switch Used for common mode testing of figure 201 103 S3 switch should be clo...

Страница 16: ...10 Figure 2 Controls Indicators Connectors MegaPulse D5 PF Rear Panel...

Страница 17: ...ir flow to cool down the tester CAUTION When installing equipment make sure not to cover the fans and have it on a proper ventilated area 4 Appliance Inlet Fuse holder Power Switch Use supplied cord s...

Страница 18: ...12 General High Voltage Electrical Diagram Figure 3 General High Voltage Electrical Diagram MegaPulse D5 PF...

Страница 19: ...has disabled the keyboard or Voltage Knob it is possible to enable them by using the next keyboard sequence 1 Turn OFF the MegaPulse P tester 2 Press and hold the TRIGGER and NOR REV buttons 3 Turn ON...

Страница 20: ...ng for a few seconds 2 While the digits are still blinking turn the VOLTAGE Adjust knob clockwise or counterclockwise to change the value of the blinking digits 3 While digits are still blinking press...

Страница 21: ...mper on the front panel 6 Disconnect all high voltage cables from the outputs 50 ohm 400 ohm Energy Measurement Point and 50k ohm if included 7 Turn the rear panel Power Switch ON If residual voltage...

Страница 22: ...RIGGER button to deliver the pulse be sure not to touch the output and return leads when pressing the trigger switch 20 Verify the amplitude of the negative pulse captured on the digital oscilloscope...

Страница 23: ...17 Figure 7 Y1 Y2 Test Output...

Страница 24: ...or value R of 100 1 which will result in a value between 99 and 101 We recommend using a value of 100 during energy calculations as a good approximation of the value for R over the test period Energy...

Страница 25: ...e used to verify that the Applied Part or Chassis of the Equipment Under Test does not exceed 1 Volt peak in accordance with IEC EN UL 60601 1 A marginally failing product will cause the voltage on th...

Страница 26: ...t the time at 500ms e Activate the Math function and turn off channel 1 and 2 9 Verify or adjust the Voltage Set Point to 5000V 10 Press the CHARGE button to start charging the internal high voltage c...

Страница 27: ...ting parameters of IEC60601 They can be used as a key for the inputs and outputs of the MegaPulse D5 PF Note the actual connections on the front panel of the D5 PF have been added to Figure 50 of IEC...

Страница 28: ...22 NOTE All D5 PF meet the specifications of IEC 60601 2 27 ed 3 0 where a 390K resistor replaced the 470K Figure 12 Example of D5 PF Connections on Figures 9A and 9B of IEC60601...

Страница 29: ...put impedance of 50kohm and switch to select trigger duration of 200ms or 20 seconds this resistance values are need when testing to IEC 60601 2 34 Ed 2 0 If testing IEC 60601 2 34 Ed 3 0 no need of a...

Страница 30: ...the Energy Measurement and Ground connectors 13 Turn ON the MegaPulse D5 PF 14 Tester is ready to CHARGE and TRIGGER with 100X Option To return the D5 PF tester to normal operation condition follow t...

Страница 31: ...ger the pulse per the directions in the user manual 6 After the pulse put the S2 switch in the SINE WAVE position to apply the sine wave Vacuum Trigger Relay WARNING For this option never exceed 20 se...

Страница 32: ...er General Maintenance To avoid contaminating the PWB with oil from your fingers handle it by the edges or wear gloves If the PWB becomes contaminated refer to the cleaning procedures given later in t...

Страница 33: ...st USA is available Phone 800 748 6224 Hours 8 00 AM 4 00 PM Pacific Time Also available on our web site at www compwest com Contact Compliance West USA 650 Gateway Center Way Suite D San Diego CA 921...

Отзывы: