VII.8 : Problem solving with overview of the error codes
WAIT 20 MINUTES – RESET THE ERROR
WITH THE KEY
MAXIMUM TEMPERATURE OF THE CONTROL BOARD
HAS BEEN REACHED
TEMPERATURE
CHECK YOUR CABLES
IN CASE THE CABLING IS OK, MEASURE
THE DC VOLTAGE BETWEEN 3-4 (12 Vdc)
IF CABLES AND PRINT ARE OK,
CONTACT YOUR DEALER
THE CONTROL BOARD DOESN’T GET ANY PULSES
FROM THE ENCODER
NO PULSES
CHECK IF THE ROLLER IS NOT BLOCKED
IF ALL IS OK RESET THE ERROR WITH
THE KEY
IN CASE THE ROLLER IS FREE AND YOU
STILL HAVE THE SAME ERROR CONTACT
YOUR DEALER
THE MAXIMUM CURRENT OF THE MOTOR HAS BEEN
REACHED
MAXIMUM CURRENT
CHECK WATER LEVEL OF THE POOL
AND RESET THE ERROR WITH THE KEY
AS SOON AS IT IS CORRECT
NO CONNECTION BETWEEN 10-11 ON THE CONTROL
BOARD
WATER LEVEL NOT CORRECT OR NO BRIDGE
BETWEEN 10-11
WATER LEVEL 1
TURN THE KEY ON THE KEYSWITCH TO
“1”
NO CONNECTION BETWEEN 8-9 ON THE CONTROL
BOARD.
STOP ACTIVATED
WAIT 10 MINUTES – RESET THE ERROR
WITH THE KEY
FACTORY SETTING OF MAXIMUM
RUNTIME = 10 MINUTES
MAXIMUM RUNTIME (10 MINUTES) OF THE MOTOR
HAS BEEN REACHED
RUNTIME ERROR
ACTION
EXPLANATION
ERROR MESSAGE
Errors can be reset by turning the key switch to “0” and again to “1” !!!
Содержание Rollo Cover
Страница 1: ...CompassPools Rollo Cover Installation Manual ...
Страница 6: ...II 1 Exploded view of the different parts of the mechanism ...
Страница 21: ...III 1 Installation sequence Drill 3 holes Ø10mm through pool and panel on the left and right hand side ...
Страница 22: ...III 1 Installation sequence Smooth the pool wall Inject enough silicone type INNOTEC ...
Страница 26: ...IV 1 Technical drawing of the SS frame Earth connection Regulating bracket ...
Страница 54: ...VII 1 Electrical preparations VII 1 Electrical preparations Motor cable is always 10m long ...