NOTE:  

If an empty bay is not available, place the replacement ECB on 

top of the rack (cabinet) or enclosure until the defective ECB is removed.

8. Insert the replacement ECB into an appropriate bay or near 

the ECB being removed.

9. Connect the open end of the ECB Y-cable to the 

replacement ECB and tighten the retaining screws.

10. Press Enter/Return.

11. Restart the “other controller” with the following 

commands:

CLEAR CLI
RESTART OTHER_CONTROLLER

IMPORTANT:  

Wait until the following message is displayed before 

proceeding:
“[DATE] [TIME] Controllers misconfigured. Type 
SHOW_THIS_CONTROLLER”

CAUTION:  

In 

step 12

, entering the appropriate SET command is 

critical. Enabling an incorrect failover mode can cause loss of data 
and incur system down time.
Verify the original failover configuration and use the appropriate 
SET command to restore this configuration.

12. Reestablish the dual-redundant configuration with one of 

the following commands:

CLEAR CLI
SET FAILOVER COPY=THIS_CONTROLLER

or

 

CLEAR CLI
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER

This command copies the subsystem configuration from 
“this controller” to the “other controller.”

IMPORTANT:  

Wait until the following message is displayed before 

proceeding:
“[DATE] [TIME]-- OTHER CONTROLLER RESTARTED”

13. Once the replacement ECB status LED turns O

N

disconnect the ECB Y-cable from the old ECB.

14. For dual ECB replacement:

a. If the “other controller” cache module will be 

connected to the replacement dual ECB, connect the PC 
or terminal to the “other controller” maintenance port.

The connected controller now becomes “this 
controller.”

b. Repeat 

step 2

 through 

step 13

.

15. Place the old ECB in an antistatic bag or on a grounded 

antistatic mat.

16. Disconnect the PC or terminal from the controller 

maintenance port.

HSG60 and HSG80 Controller Configurations

Use the following steps and 

Figure 1

 through 

Figure 5

, a

appropriate, to replace an ECB in single-controller and 
dual-redundant controller configurations using FRUTIL:

1. Connect a PC or terminal to the maintenance port of the 

controller that has the defective ECB.

The controller connected to the PC or terminal becomes 
“this controller.”

2. For StorageWorks Model 2100 and 2200 enclosures, enter 

the following command to verify that system time is set:

SHOW THIS_CONTROLLER FULL

3. If system time is not set or current, enter current data using 

the following command:

SET THIS_CONTROLLER 
TIME=dd-mmm-yyyy:hh:mm:ss

IMPORTANT:  

An internal clock monitors the life of the ECB battery. This 

clock must be reset after replacing an ECB.

4. Start FRUTIL with the following command:

RUN FRUTIL

5. Continue this procedure as determined by the enclosure 

type:

StorageWorks Model 2100 and 2200 enclosures

All other supported enclosures

StorageWorks Model 2100 and 2200 enclosures

a. Follow on-screen instructions to replace the ECB.

CAUTION:  

Make sure to install the replacement ECB in a bay that 

supports the same cache module as the current ECB being 
removed (see 

Figure 4

).

Remove the blank bezel from this replacement bay and reinstall 
the blank bezel in the bay vacated by the current ECB. Failure to 
reinstall the blank bezel might cause an over temperature 
condition and damage the enclosure.

NOTE:  

Install a Battery Service Label on the replacement ECB prior 

to installing the ECB in the enclosure. This label indicates the 
installation date (MM/YY) for the replacement ECB.

b. Install a Battery Service Label on the replacement ECB 

as described by the Compaq StorageWorks ECB Battery 
Service Label Placement
 installation card.

c. Remove the blank bezel from the appropriate bay and 

install the replacement ECB.

IMPORTANT:  

Do not

 remove the old ECB until the ECB charged LED 

on the replacement ECB turns O

N

 (see 

Figure 3

1

).

d. Remove the old ECB and install the blank bezel in this 

bay.

e. Press Enter/Return.

The ECB expiration date and deep discharge history are 
updated.

FRUTIL exits.

f. Disconnect the PC terminal from the controller 

maintenance port.

Содержание StorageWorks HSG60

Страница 1: ...tem For instructions on upgrading a single controller configuration to a dual redundant controller configuration refer to the appropriate array controller user guide or maintenance and service guide E...

Страница 2: ...2100 and 2200 enclosure ECB Figure 4 ECB and cache module locations in a StorageWorks Model 2100 and 2200 enclosure IMPORTANT When replacing an ECB see Figure 5 match the vacant ECB bay with the supp...

Страница 3: ...n a grounded antistatic mat HSZ70 Dual Redundant Controller Configurations Use the following steps and Figure 1 or Figure 2 to replace an ECB 1 Connect a PC or terminal to the maintenance port of the...

Страница 4: ...te to replace an ECB in single controller and dual redundant controller configurations using FRUTIL 1 Connect a PC or terminal to the maintenance port of the controller that has the defective ECB The...

Страница 5: ...if desired enter current data using the following command SET THIS_CONTROLLER TIME dd mmm yyyy hh mm ss IMPORTANT An internal clock monitors the life of the ECB battery This clock must be reset after...

Страница 6: ...ins to contact ground resulting in cache module damage NOTE If an empty bay is not available place the replacement ECB on top of the enclosure or at the bottom of the rack 6 Insert the replacement ECB...

Страница 7: ...de IMPORTANT Make sure to identify the existence of this updated table in the user guide Table 1 ECB Status LED Displays LED Display ECB State Definition Startup Checking temperature and voltage If th...

Отзывы: