3-8
Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant DL380
Compaq Confidential – Need to Know Required
Writer:
Rachel Williams
Project:
Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant DL380
Comments:
Part Number:
221544-001
File Name:
d-ch3 Installing Software.doc
Last Saved On:
12/27/00 10:59 AM
3.
From the options presented to you, select the following:
G
Select your particular server from the list presented to you.
G
Select the appropriate model or
All Models
.
G
Select SCO UnixWare 7 from the list of operating systems.
4.
Select the Softpaq for ServerNet Verification Utilities.
At the download page, follow the directions for downloading the Softpaq and
creating diskettes. Create two ServerNet Verification Utilities diskettes.
Verifying the Local Adapter
To verify that the local ServerNet I adapter is properly installed and
functional, on each node that has a ServerNet I adapter, follow these steps:
1.
Have a ServerNet I Verification Utilities diskette for each server.
2.
Insert the proper diskette into the server that you want to test. Reboot
the node. Wait for the DOS prompt to be displayed.
3.
Type
spaf
a
t the DOS prompt, and then press
Enter
. A title screen
displays.
4.
Press any key to start the test of the ServerNet I links. The following
messages display:
LINK X IS ALIVE
LINK Y IS ALIVE
Verify that the links are alive. If either link is reported
NOT ALIVE
, a
problem exists with the adapter. Press
Esc
to stop the ServerNet I link
test. Power down the server, disconnect all power to the server, reseat
the board, and then repeat the test.
5.
Press
Esc
to exit the ServerNet I Utility or press any other key to start
the loopback test. The loopback test status displays. If a loopback error
occurs, the error displays, and the test fails.
6.
Press any key to stop the loopback test.