1-8
Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant DL380
Compaq Confidential – Need to Know Required
Writer:
Rachel Williams
Project:
Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant DL380
Comments:
Part Number:
221544-001
File Name:
b-ch1 Clustering Overview.doc
Last Saved On:
12/27/00 10:58 AM
Compaq ServerNet Verification Utility (SVU)
The Compaq ServerNet Verification Utility (SVU) verifies proper installation
and cabling of the Compaq ServerNet I interconnect before a UnixWare
software installation. The SVU is a utility run from bootable diskettes inserted
into each cluster node. For more information on creating the diskettes and
running the SVU, refer to Chapter 3, “Installing Cluster Software,” of this
guide.
Compaq SmartStart and Support Software CD
SmartStart is located on the SmartStart and Support Software CD shipped with
ProLiant
servers. This CD is required for ServerNet I configurations. You can
also use the CD to configure additional hardware. For information concerning
SmartStart, refer to the Compaq Server Setup and Management package that
comes with your server. The following utilities on the SmartStart CD are used
for your cluster:
■
Compaq Array Configuration Utility (ACU)
The ACU is an offline tool that is used to configure the array controller,
add disk drives to an existing configuration, and expand capacity.
■
Options
ROMPaq
™ Utility
The SmartStart and Support Software CD contains the Options
ROMPaq
Utility. Options ROMPaq updates the firmware on the disk
drives and controller.
■
Fibre Channel Fault Isolation Utility (FFIU)
The FFIU verifies the integrity of the Fibre Channel Arbitrated Loop
(FC-AL) installation. This utility provides fault detection and help in
locating a failing device on the FC-AL.