Troubleshooting
5-7
Compaq Confidential – Need to Know Required
Writer:
Rachel Williams
Project:
Compaq ProLiant Clusters for SCO UnixWare 7 U/300 Quick Install Guide for the Compaq ProLiant DL380
Comments:
Part Number:
221544-001
File Name:
f-ch5 Troubleshooting.doc
Last Saved On:
12/27/00 11:01 AM
Table 5-3
Solving Node-to-Node Communication Problems
continued
Problem
Possible Cause
Action
RA4100 storage subsystems
or hubs are not powered up
Apply power to the hubs and storage
subsystems.
Ethernet connection failed
(and the CI serial cable is not
used)
Power down the cluster. Check the
Ethernet crossover cable to determine
that the cable is properly connected, or
is not crimped or compromised in any
way. If necessary, replace the Ethernet
crossover cable.
After the Ethernet connection is
repaired, boot the cluster.
Alternating root node panics
(RA4100 system)
Both ServerNet I connections
failed (and the CI serial cable
is not used)
Power down the cluster. Check the
ServerNet I cables to determine that the
cables are properly connected, do not
have bent pins, and are not crimped or
compromised in any way. If necessary,
replace the ServerNet I cables.
Verify the ServerNet I connections using
the SVU as described in Chapter 3 of this
guide. After the ServerNet I connections
are repaired, boot the cluster.