background image

Index

Modular SAN Array Fabric Switch 6 User Guide

Index-7

COMPAQ CONFIDENTIAL

Writer: Kim L. Miller File Name: k-index.doc

Codename: Millebourne Part Number: 230394-002 Last Saved On: 7/11/02 2:30 PM

troubleshooting

cabling   4-2, 4-7
connection problems   4-6
fibre channel cables   4-7
first stage   4-2
guidelines   4-1
MSA Fabric Switch 6   4-1
preventative maintenance   4-1
serial communication problems   4-6
SFPs   4-7
temperature control problems   4-8

U

user interfaces, listed   2-2

V

versions, Switch Management Utility,

finding   E-1

W

warnings

defined   1-1, D-1

websites

Compaq   xi

Windows NT

setting up HyperTerminal properties   2-4

wrist straps

specifications   B-2
using   B-2

Z

zoning

setting up with the management

utility   3-50

Содержание ProLiant 6/450 MHz

Страница 1: ...AN Array Fabric Switch 6 User Guide Part Number 230934 002 June 2002 Second Edition This guide is designed to be used as step by step instructions for installation and as a reference for operation tro...

Страница 2: ...Compaq shall not be liable for technical or editorial errors or omissions contained herein The information in this document is provided as is without warranty of any kind and is subject to change with...

Страница 3: ...tability ix Symbols in Text ix Text Conventions x Related Documents x Getting Help x Compaq Technical Support xi Compaq Website xi Compaq Authorized Reseller xi Chapter 1 Overview of the Switch The MS...

Страница 4: ...guration Utility XE ACU XE to Configure the Switch 2 12 Accessing the Switch Configuration Option of the ACU XE 2 13 Initial Switch Configuration 2 16 Advanced Switch Configuration 2 18 Chapter 3 MSA...

Страница 5: ...rial Communication Problems 4 6 Connections 4 6 Compaq supported Small Form Factor Pluggables SFP 4 7 Fibre Channel Cables 4 7 Temperature Control 4 8 Preventative Maintenance Solutions 4 8 Appendix A...

Страница 6: ...itations for Zone Members Zones and Zone Sets C 39 Using the CLI to Configure Zoning C 40 Appendix D Laser Precautions and Fibre Cables Laser Precautions D 1 Fibre Channel Cable D 2 Appendix E Updatin...

Страница 7: ...ystem administration experience Important Safety Information Before installing this product read the Important Safety Information document provided Symbols on Equipment The following symbols may be pl...

Страница 8: ...lectric shock fire or damage to the equipment do not plug telephone or telecommunications connectors into this receptacle This symbol indicates the presence of a hot surface or hot component If this s...

Страница 9: ...may become unstable if more than one component is extended for any reason Symbols in Text These symbols may be found in the text of this guide They have the following meanings WARNING Text set off in...

Страница 10: ...nd so on and for keyboard keys Monospace typeface is used for command lines code examples screen displays error messages and user input Sans serif typeface is used for uniform resource locators URLs R...

Страница 11: ...sure to have the following information available before you call HP Technical support registration number if applicable Product serial number Product model name and number Applicable error messages A...

Страница 12: ...ial Configuration of the Switch Chapter 2 MSA Fabric Switch 6 Management Utility Chapter 3 Troubleshooting Chapter 4 Regulatory Compliance Notices Appendix A Electrostatic Notices Appendix B Command L...

Страница 13: ...ay Fabric Switch 6 User Guide The MSA Fabric Switch 6 The MSA Fabric Switch 6 is an integrated six port module featuring a 12 Gbps switch engine that enables full duplex non blocking performance on al...

Страница 14: ...and receive data for an aggregate of 2 Gbps Automatic Port Bypass Improves SAN reliability by automatically bypassing errant ports Global Status Indicator GSI RS 232 serial interface port for configu...

Страница 15: ...hapter 4 Troubleshooting RS 232 DB 9 Serial Port A male serial port that may be connected to a host system with a standard 9 pin female to 9 pin female null modem cable This port can be used to perfor...

Страница 16: ...or a terminal emulator connected to the DB 9 serial port Refer to Chapter 2 Initial Configuration of the Switch for more detailed information on this subject DB 9 Serial Cable This connector is provid...

Страница 17: ...it properly 1 Power on the MSA1000 On power up the switch will run several POST tests and the GSI indicator will display changing patterns refer to the section Reading the Global Service Indicator in...

Страница 18: ...edures used to initially configure the MSA Fabric Switch 6 Preliminary switch configuration includes entering the Ethernet and the SNMP settings Two configuration methods are available Using the text...

Страница 19: ...the serial port in the front of the switch or remotely through the switch s Ethernet interface using telnet During initial set up it is accessed through the text based UI Subsequently the system defau...

Страница 20: ...that when using telnet you can only get access to the switch after it has started up and has initialized its network parameters Consequently you must have a directly connected terminal to initially co...

Страница 21: ...nications port assigned to the serial port for example COM1 COM2 and click OK In the properties dialog box enter the following port settings and select OK Table 2 1 Default Serial Port Settings Type S...

Страница 22: ...the text base UI 1 At the Login prompt enter user as the login variable Login user 2 At the password prompt enter the assigned password Password ADMIN Upon successful login the main menu is displayed...

Страница 23: ...re 2 2 The first option in this menu allows the user to return to the main menu Any changes made are reset to the previous value The second third and fourth parameters are used to configure the Ethern...

Страница 24: ...figure below It displays the current IP address The default 127 0 0 1 is set at the factory This address should be changed to an IP address appropriate to your site Check with the network administrato...

Страница 25: ...Network Parameters menu to call up the Subnetwork Mask Menu The default subnetworking mask is a Class C mask as shown in the figure below This mask will work in many installations as Class C IP networ...

Страница 26: ...MSA Fabric Switch 6 over the Ethernet from systems on other segments In both of these cases the MSA Fabric Switch 6 will need the IP address of the gateway system in order for it to function Direct qu...

Страница 27: ...or to enter a new SNMP get community name 3 Set SNMP set community string calls up the SNMP Set Community Name menu This allows the user to restore the default SNMP set community name or to enter a n...

Страница 28: ...e unit s serial number and Ethernet MAC address Accessing the CLI Select option 4 Command line interface on the main menu to call up the command line interface This gives the user the ability to chang...

Страница 29: ...on includes setting the IP address Subnet Mask and Default Gateway of the switch and the redundant switch if installed Until these Ethernet and SNMP parameters are entered a Web Browser cannot find or...

Страница 30: ...t screen or by selecting Start Programs Compaq System Tool Compaq Array Configuration XE Figure 2 7 is an example of the Compaq Web Based Management screen Figure 2 7 Compaq Web Based Management scree...

Страница 31: ...are displayed at the bottom portion of the screen Assisted Configuration is used to configure the controller Advanced Configuration is used to configure the controller Switch Configuration is used to...

Страница 32: ...Initial Configuration of the Switch Modular SAN Array Fabric Switch 6 User Guide 2 15 Figure 2 9 Switch selection 4 Select a switch to configure...

Страница 33: ...tion of these configuration task options During the initial configuration of the switch only one option is displayed If the switch has already been configured and is active additional tasks are displa...

Страница 34: ...6 User Guide 2 17 Figure 2 11 Switch parameters input screen 2 Enter the following information IP Address Default Gateway Subnet Mask Read and Write Community strings 3 Click Finish to save the setti...

Страница 35: ...tility is part of the MSA Fabric Switch 6 Management Utility that resides on the switch itself Parameters more advanced than those offered by ACU XE are available in the Management Utility Figure 2 12...

Страница 36: ...This chapter describes how to use the Management Utility on the MSA Fabric Switch 6 The following sections describe the process to launch the Management Utility on your switch Defining System Requirem...

Страница 37: ...be downloaded from the web or installed from Modular SAN Array 1000 Support Software CD ROM To download the Java plug in from the Web 1 Go to http java sun com using Netscape Navigator or Internet Exp...

Страница 38: ...s of the switch you want to manage into the web browser s address box 2 Once the Utility is launched enter the SNMP Read Community and Write Community strings into the appropriate test boxes NOTE Thes...

Страница 39: ...ribing the Console The Management Utility provides a web browser based user interface so the MSA Fabric switch 6 can be easily managed The opening window as shown in the figure below consist of three...

Страница 40: ...s which of the management tasks you will operate using the Management Utility Figure 3 3 is sample of the Task Selection toolbar Figure 3 3 Task selection toolbar Status Panel The Status Panel is loca...

Страница 41: ...been acknowledged by clicking the icon or clicking the Clear Status button A Chassis Temperature icon in the Amber fault state will not return to the Normal State until the fault condition is correct...

Страница 42: ...3 2 Message Text Line EventPostFault System event detected Alert EventTempFaultAct System event detected Alert EventTempFaultDeact System event detected Alert EventPortStatus Port event detected Notif...

Страница 43: ...state The indicators will not return to the Normal State until the fault condition is corrected Cancel Cancels the current activity Refresh Contacts the MSA Fabric switch 6 being monitored and refres...

Страница 44: ...bed configuration panels Port Summary Tab Port Events Tab Port Control tab Port Statistics Tab SFP Tab If you select the switch from the menu tree the Summary and Events tabs will be available while t...

Страница 45: ...itch 6 User Guide In addition the indicators that are displayed on the switch graphic reflect the indicators that are configured on the switch and display the same status that is currently on the swit...

Страница 46: ...n the System Information button is selected from the Task Selection toolbar you can manage and monitor global parameters for the switch It provides a set of tabbed panels that provide access to a set...

Страница 47: ...mation for connected devices as shown in the following figure The devices displayed in the table can be filtered by selecting the switch a port or a device from the tree Selecting the switch will show...

Страница 48: ...r Guide 3 13 Session Configuration When the Session Configuration button is selected the SNMP settings are provided for this session of the Management Utility application as shown in the following fig...

Страница 49: ...AN Array Fabric Switch 6 User Guide Help When the Help button is selected the application information and service contact information is provided as well as access to the on line help system as shown...

Страница 50: ...The following sections will help you to use the Management Utility Managing and Monitoring individual ports Managing from the system information panel Monitoring from the Device View Session Configura...

Страница 51: ...ts on the MSA Fabric Switch 6 being monitored It also provides configuration and operation information about individual ports that are selected from either the tree representation or the switch graphi...

Страница 52: ...eground display when the Port button on the toolbar is clicked It consists of a table that describes the status and configuration of each of the ports on the switch The following figure is an example...

Страница 53: ...ffline port was taken offline by management No media installed no SFP installed Link down SFP is installed but with no link established Link up SFP is installed and a link to the device is established...

Страница 54: ...orts related events generated by the MSA Fabric Switch 6 being monitored as shown in the following figure This events table as shown in the following figure displays the parameters described in the fo...

Страница 55: ...e event The possible event type parameters are Unknown Other Status Configuration Topology Description The message generated by the event Port Control Tab The Port Control window is accessed by clicki...

Страница 56: ...SAN Array Fabric Switch 6 User Guide 3 21 The following figure provides an example of the Port Reset display you must use the scroll bar at the right side of the panel to bring the Port Reset display...

Страница 57: ...installed and a link to the device is established Link active SFP is installed a link to the device is established and traffic is flowing Isolated it is understood that the other port is an E port but...

Страница 58: ...ion The assigned path is determined by the smallest cost You will only change this value if you want to tune or manually configure the routing to force routing to select a different path However you m...

Страница 59: ...he number of 4 byte words transmitted out of this port 4 byte Words Received The number of 4 byte words received at this port Transmitted Broadcast Frames The number of broadcast frames or packets tra...

Страница 60: ...port Error Statistics contains the number of occurrences of the statistics and error parameters shown the following table Except for Link Resets all of the parameters listed here are a part of the li...

Страница 61: ...he number of frames received with invalid CRCs Receive Dropped Frames The number of frames that were dropped on receive Transmit Dropped Frames The number of frames that were dropped on transmit Stat...

Страница 62: ...MSA Fabric Switch 6 Management Utility Modular SAN Array Fabric Switch 6 User Guide 3 27 Figure 3 16 Error statistics view Figure 3 17 Stat counter reset view...

Страница 63: ...the selected port from any of the following categories Transmitter Operational Vendor Shortwave and Longwave Use the scroll bar on the right side of the panel to view additional data The following fi...

Страница 64: ...MSA Fabric Switch 6 Management Utility Modular SAN Array Fabric Switch 6 User Guide 3 29 Figure 3 19 SFP tab transmitter display second part Figure 3 20 SFP tab operational display...

Страница 65: ...MSA Fabric Switch 6 Management Utility 3 30 Modular SAN Array Fabric Switch 6 User Guide Figure 3 21 SFP tab vendor display Figure 3 22 SFP tab vendor display second part...

Страница 66: ...y allows you to perform a variety of management and monitoring functions relevant to the MSA Fabric Switch 6 you are managing as shown in the following figure Figure 3 23 System information panel The...

Страница 67: ...h Tab The Switch Health window is the default tab that is displayed when the System Information button is clicked for the first time It can also be displayed by clicking the Health tab It consists of...

Страница 68: ...ature that is currently set or Failed if it is above The operating temperature of the switch must be kept between 10 and 40 degrees Celsius between 50 and 104 degrees Fahrenheit Temperature Reading Cu...

Страница 69: ...he Information window is accessed by clicking the Information tab of the System Information display It consists of two separate panels that provide identification and firmware version information abou...

Страница 70: ...Description Identification Device Description Product Name of the MSA Fabric Switch 6 that is being managed Device SN Serial number of the switch being managed MAC address MAC address of the switch b...

Страница 71: ...ide Switch Control Tab The Switch Control window is accessed by clicking the Switch Control tab of the System Information display It consists of three panels Switch Configuration Switch Reset and Rest...

Страница 72: ...ween 1 and 255 can be used for this setting A lower number results in a higher priority for the switch The switch with the lowest priority number will become the principal switch If two switches have...

Страница 73: ...ound the failure Choosing On enables Forced In Order delivery when the fabric topology is changed Use with care as enabling this feature will cause a delay when a trunk failure occurs Choosing Off dis...

Страница 74: ...erly without a valid gateway address If you are using the default gateway address 0 0 0 0 or an invalid gateway address you will need to change the address to a valid one To check the gateway address...

Страница 75: ...itch 6 SNMP Trap Management Stations This panel as shown above in Figure 3 27 allows you to add and remove stations that have SNMP traps forwarded to them To add a station type its IP address and Port...

Страница 76: ...tab This window allows you to read the location and contact information that is currently configured for the switch and to modify it by selecting it and editing All the information in this panel is fo...

Страница 77: ...d by clicking the Firmware tab of the System Information display This window as shown in the figure below allows you to download new firmware to your MSA Fabric Switch 6 To perform a download using th...

Страница 78: ...r of times you want the switch to try downloading the new firmware before quitting Last Download Status This parameter reports either success or failure for the last download operation Download Only C...

Страница 79: ...TFTP server You can also restore any previously saved configuration to the switch To perform either a backup or restore operation enter the correct parameters for Backup Restore File Set and TFTP Serv...

Страница 80: ...name for the set of files that contains the backup configuration TFTP Server IP Address The IP address of the TFTP server that you want to save a configuration file to or restore a configuration file...

Страница 81: ...ndow is accessed by clicking the Events tab of the System Information display It consists of a table that lists all of the events generated by the switch being monitored as shown in the following figu...

Страница 82: ...display all the events Show Port Events Selecting Port Events will filter the list so that only the events related to the ports and not the entire system will be listed Selecting both System Events an...

Страница 83: ...the devices connected to the switch Selecting members from the tree acts like a list filter Selecting the switch in the tree will list information about all the devices connected to the switch Selecti...

Страница 84: ...scribed in the following table Table 3 16 Session Configuration Window Parameter Description Polling Rate This setting allows you to specify the rate for detecting the changes of devices in the networ...

Страница 85: ...g the Command Line Interface CLI If the values do not match the utility will not be able to modify any values in the switch If the community strings specified do not match what is configured in the sw...

Страница 86: ...e disrupted For best results only add a switch configured with zoning to a fabric configured with the same zoning configuration Zone Members Zone members are Fibre Channel edge devices that are identi...

Страница 87: ...ltiple zone sets However only one of these zone sets can be active at a time The other zone sets can be used as backup trials or other user defined configurations Naming Rules for Zone Members Zones a...

Страница 88: ...6 Management Utility allows you to display zoning in two ways Merged zones Local zones To toggle between the Merged Zones display and the Local Zones display expand the Zoning View drop down list in...

Страница 89: ...edit and remove zone sets zones and zone members using the Local Zones view Using the Fabric Switch 6 Management Utility to Configure Zoning This section describes how to use the MSA Fabric Switch 6 M...

Страница 90: ...bled To enable zoning 1 In the Switch Control tab of the System Information screen select the Zoning Configuration On radio button Figure 3 33 is an illustration of the Zoning Configuration option in...

Страница 91: ...ation screen is displayed Figure 3 34 is an illustration of the Zoning Configuration screen IMPORTANT To create or edit Zone Sets Zones and Zone Members the Local Zones view must be displayed To chang...

Страница 92: ...b In the Edit window change the name of the Zone Set to the new name c Click OK Creating Zones To create new Zones 1 In the Zones column of the Zoning Configuration screen click Add 2 Enter the name...

Страница 93: ...ne Set is shown in bold on the screen 2 Click Apply The selected Zone Set is now the active Zone Set used by the switch Example Zoning Configuration Assume the following Server1 needs to access Disk1...

Страница 94: ...2f78 Web_Zone Tape1 WWPN 210000010241ff73 Web_Zone and Mail_Zone Raid1 WWPN 210000010249a7ab Web_Zone and Mail_Zone Server2 WWPN 100000a0c99ae47a Mail_Zone Disk2 WWPN 200000600819ae48 Mail_Zone MIS_NT...

Страница 95: ...Troubleshooting the MSA Fabric Switch 6 with the status indicator and Reset Button Preventive Maintenance Solutions Troubleshooting Guidelines If there is a problem accessing a device connected to the...

Страница 96: ...on the switch may be faulty or the temperature may be out of defined limits 3 Inspect the cabling between the switch and attached Fibre Channel devices Check for loose dirty broken or bent cabling and...

Страница 97: ...is is the normal state when powered on Green OFF There is no power within the switch The Fabric Switch 6 may not be plugged in to the MSA SAN Array 1000 correctly The MSA SAN Array 1000 may be disconn...

Страница 98: ...urs too often check for excessive LIPs Green OFF Switch is not re initializing Normal state Reading the Ethernet Indicators Table 4 2 Ethernet Indicators Label Color Pattern Interpretation Possible Ca...

Страница 99: ...ing could be the cause The network is down for some reason Check to see if other systems on the network are functioning The switch is not connected to the network Check the cable to see if it is seate...

Страница 100: ...ror Blinking amber Blinking amber Speed mismatch Conflict defined speed Both indicators on port blinking simultaneously Blinking green Blinking green Beaconing MSA1000 feature All port indicators blin...

Страница 101: ...that appears physically damaged This may result in permanent damage to the switch Keep unused SFP connectors covered with the plugs that are shipped with them to prevent contamination from obscuring...

Страница 102: ...tures and intermittent signals Keep unused cable ends covered to prevent contamination from obscuring or attenuating the light signals IMPORTANT Always use an anti static wrist strap while handling SF...

Страница 103: ...eripheral devices into two classes A and B depending upon their intended installation Class A devices are those that may reasonably be expected to be installed in a business or commercial environment...

Страница 104: ...pment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense Modifications The FCC requires the user to b...

Страница 105: ...EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community Compliance with these directives implies conformity to the following European Norms in brackets are the e...

Страница 106: ...his type of damage may reduce the life expectancy of the device To prevent electrostatic damage observe the following precautions Avoid hand contact by transporting and storing products in static safe...

Страница 107: ...n the ground cords To provide proper ground wear the strap snug against the skin Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conduc...

Страница 108: ...xity This more advanced level of parameters operates from a command line interface CLI This chapter includes information on Invoking the Command Line Interface Using the Command Line Interface Setting...

Страница 109: ...name server information PortCtl Displays modifies the port settings PortReSet Resets selected switch ports PortStatS Displays the port statistics PortStatUs Displays the port status PortTp Displays t...

Страница 110: ...ray Fabric Switch 6 User Guide C 3 Invoking the Command Line Interface The CLI can be called up by choosing 4 Command line interface on the main menu It will respond with a cmd prompt as shown in the...

Страница 111: ...an best be seen by typing help More detailed information is available by typing help followed by a command name as shown below cmd help command_name Figure C 2 Help menu By typing the Help command you...

Страница 112: ...ure C 3 Logout screen Exiting from CLI The Exit command of the CLI returns the user to the main menu The Exit command can be distinguished from the Logout command in that the user does not exit the pr...

Страница 113: ...he TFTP server specified by the IP address Configuration restore reconfigures the switch based on the files specified by file from the TFTP server specified by the IP address NOTE When using the backu...

Страница 114: ...Array Fabric Switch 6 User Guide C 7 Examples Figure C 5 Config command Exit Exits the command line interface and returns to the main menu Syntax Exit Examples cmd Exit Fabric Displays all of the swi...

Страница 115: ...in the factory default settings CLI command factory defaults are Table C 2 Factory Defaults CLI Command User ID Parameter Default Value Beacon User User On Off Config User User Backup Filename Backup...

Страница 116: ...ilter telnet display level filter telnet display module filter 115 upload TFTP file name upload TFTP IP address port message level Fatal Warn Status Inform All modules None All modules None All module...

Страница 117: ...slation Send FAN Min LSA arrival Min LSA interval LSA refresh interval LSA max age FC Switch 1 254 off off 1 5 1800 3600 Temp User Threshold 50c Tftpdl User Download file name TCTP IP address Request...

Страница 118: ...sed with a command name to describe a command function Syntax Help Help command Help Displays the list of commands that are available from this interface Help command Displays a description of the com...

Страница 119: ...Command Line Interface C 12 Modular SAN Array Fabric Switch 6 User Guide Figure C 9 Supported commands Hwcfg Displays the hardware configuration of the switch Syntax HwCfg...

Страница 120: ...display the entries contained in the event log buffer Upload will upload the event log entries to the server specified by Tftplp into a file specified by Tftp Filename Press Ctrl C to temporarily dis...

Страница 121: ...Modify TFTP server IP address Log List Display entries in the event log Log Upload Upload event log entries to TFTP server level d debug i information w warning f fatal s status g gsos n none mod hex...

Страница 122: ...ut command NetCfg Displays switch network settings Syntax Netcfg Examples Figure C 13 Netcfg command NS Displays the local and global name server NS table entries Syntax NS NS d NS All NS All d Where...

Страница 123: ...ies the port control settings Syntax PortCtl PortCtl port_number Public public_state PortCtl port_number Type port_type PortCtl port_number Speed port_speed PortCtl port_number Heartbeat heartbeat_rat...

Страница 124: ...ports to autonegotiate their port type FL Sets individual port or all ports to the FL port type F Sets individual port or all ports to the F port type PortCtl port_number Speed port_speed Sets the por...

Страница 125: ...Cost routing_cost Sets the routing cost variable for an individual port or all ports routing_cost variables Description 100 5000 Sets the routing cost between 100 and 5000 Examples Figure C 15 PortCtl...

Страница 126: ...Figure C 17 PortCtl public command Syntax PortCtl port_number public public_state Figure C 18 Portctl type command Syntax PortCtl port_number Type port_type Figure C 19 PortCtl speed command Syntax Po...

Страница 127: ...Syntax PortStatS Display statistic for all ports PortStatS port Display statistic for specified ports PortStatS r Reset stat counters for all ports PortStatS port r Reset stat counters for specified p...

Страница 128: ...counters for all ports on the switch PortStatS port_number Resets the statitics counters for the port specified on the switch Examples Figure C 22 Portstats command PortStatUs Displays port status Sy...

Страница 129: ...abric Switch 6 User Guide Examples Figure C 23 Portstatus command Figure C 24 Portstatus with port number Syntax PortStatUs port_number PortTp Continuously display the throughput for all of the ports...

Страница 130: ...Displays and modifies the SNMP system variables Syntax SNMP SNMP Name name_text SNMP Con contact_text SNMP Loc location_text This command displays or modifies the MIB2 system strings System contact c...

Страница 131: ...me name_text Sets the SNMP Name for the switch to the text typed in place of the name_text variable SNMP Con contact_text Sets the SNMP Contact for the switch to the text typed in place of the contact...

Страница 132: ...Command Line Interface Modular SAN Array Fabric Switch 6 User Guide C 25 Figure C 29 SNMP con command Figure C 30 SNMP loc command...

Страница 133: ...l Priority 1 255 Set switch priority SwCtl TRAnslation ON OFF Turns address translation on off SwCtl SendFan ON OFF Turns fabric address notification on off SwCtl CirCumUpTime Clear cumulative up time...

Страница 134: ...d Line Interface Modular SAN Array Fabric Switch 6 User Guide C 27 Figure C 32 Swstate command ports data information Swstatus Displays the switch status Syntax Swstatus Example Figure C 33 Swstatus c...

Страница 135: ...it It also allows you to modify the switch temperature threshold Syntax Temp Temp temperature_threshold Temp Displays the current temperature of the switch and the current threshold setting Temp temp...

Страница 136: ...the number typed in place of the ip_address variable TftpDl ReqTimeOut req_timeout Sets the time in milleseconds during which the switch will request the TFTP server to download the image file before...

Страница 137: ...iables Description reset_state yes Sets switch to automaticly reboot after a new boot image has been down loaded to it no Sets switch tonot automaticly reboot after a new boot image has been downloade...

Страница 138: ...ogy d TOpology domain_Id_number Topology Displays the information for all of the switches in the network Topology d Displays the information for all of the switches in the network without pausing and...

Страница 139: ...s The ip port specifies the trap IP address and trap port address The format for ip port is ip ip ip port 8 trap entries are supported Valid range for ip is 0 255 Valid range for port is 1 2147483647...

Страница 140: ...ap recipient that you want to add The default is 162 Traps Delete ip_address port_number This command is used to delete trap recipients from the recipients list The command variables are defined as fo...

Страница 141: ...level of severity Alert Filters for traps of the type Alert Crit Filters for traps of the type Critical ERr Filters for traps of the type Error Warn Filters for traps of the type Warn Notify Filters...

Страница 142: ...The port number of the SNMP trap recipient whose state you want to set trap_state active Sets the specified port recipient to the Active state Traps configured to be sent to this device will be forwar...

Страница 143: ...Command Line Interface C 36 Modular SAN Array Fabric Switch 6 User Guide Figure C 39 Traps delete command Figure C 40 Traps filter command Figure C 41 Traps state command...

Страница 144: ...rted by the MSA Fabric Switch 6 It describes zoning at the individual switch and describes how the merge command functions are used to support zoning across a Fabric Zoning Elements Before performing...

Страница 145: ...stems Disk drives Tape libraries IMPORTANT The World Wide Node Name WWNN of the Fibre Channel device cannot be used to create a zone member WWNN bases zoning is expressly prohibited in the FC MI stand...

Страница 146: ...a letter a z and can be either upper case or lower case Other characters of the name any characters besides the first character can be a letter a z either upper or lower case a number 0 9 or a symbol...

Страница 147: ...he active table The zoning configuration procedures are detailed in the following paragraphs and use the following scenario Assume the following Server1 needs to access Disk1 exclusively for Operating...

Страница 148: ...ne Set MIS_NT CLSTR1_SAN1 contains two zones Web_Zone contains the following Zone Members Server1 Disk1 RAID1 and Tape1 Mail_Zone contains the following Zone Members Server2 Disk2 RAID1 and Tape1 Stag...

Страница 149: ...the pending table cmd zone pending Inactive zoneset set1 contains 1 zone s zone ntgroup1 contains 0 member s Inactive Zoneset set2 contains 1 zone s zone solaris1 contains 0 members Inactive zoneset s...

Страница 150: ...MIS_NT_CLSR1_SAN1 Zone Mail_Zone added to zoneset MIS_NT_CLSTR1_SAN1 Changes will only take effect after a zone write command Adding zone members to the zones Add zone members to your zones using the...

Страница 151: ...zone Mail_Zone Zone member 210000010249a7ab already exists added to zone Mail_Zone Changes will only take effect after a zone write command Changing the names of the zone members optional To assign a...

Страница 152: ...one write command cmd zone renzm WWN 210000010241ff73 Tape1 Renamed zonemember WWN 210000010241ff73 to Tape1 Changes will only take effect after a zone write command cmd zone renzm WWN 210000010249a7a...

Страница 153: ...re correct Viewing all zone sets their zones and zone members in the pending table Viewing the zone set in the pending table Viewing the zones in the pending table Viewing the zone members in the pend...

Страница 154: ...one Web_Zone contains 4 member s zone member 1000000102421303 zone member 2100005004d02f78 zone member 210000010241ff73 zone member 210000010249a7ab zone Mail_Zone contains 4 member s zone member 2100...

Страница 155: ...r 210000010241ff73 zone member 210000010249a7ab zone Mail_Zone contains 4 member s zone member 210000010241ff73 zone member 210000010249a7ab zone member 100000a0c991a47a zone member 200000600819ae48 C...

Страница 156: ...Active zoneset MIS_NT_CLSTR1_SAN1 contains 2 zone s zone Web_Zone contains 4 member s zone member 1000000102421303 zone member 2100005004d02f78 zone member 210000010241ff73 zone member 210000010249a7a...

Страница 157: ...and Fibre Channel Cable Connector Cleaning Considerations Optics are susceptible to anything that hinders light transmission Consequently manufacturers of both 2 Gb Small Form Factor Pluggable Transce...

Страница 158: ...The MSA Fabric Switch 6 is intended primarily for use with Shortwave SFPs and multi mode Fibre Channel cables While Longwave SFPs can be used with 9 um single mode Fibre Channel cables performance may...

Страница 159: ...CAUTION Make certain the Fibre Channel cables are installed and supported so that no excess weight is placed on the Fibre Channel connectors This is necessary to prevent damage to the connector and ca...

Страница 160: ...bsite www compaq com storageworks or the MSASW6 txt file on the Modular SAN Array 1000 Support Software CD ROM Finding the MSA Fabric Switch 6 Management Utility Version Number The current version of...

Страница 161: ...nload file by the MSA Fabric Switch 6 once the transfer is complete The boot file name needs to be set for a successful update Typically both the timeout and retry parameters do not require resetting...

Страница 162: ...he MSA Fabric Switch 6 Management Utility package number is compared with the package already resident in the MSA Fabric Switch 6 If the MSA Fabric Switch 6 Management Utility being downloaded is newe...

Страница 163: ...e null modem connected and HyperTerminal running reset the switch To access the Boot Menu you must press the Enter key when prompted this occurs within the first few seconds following the reset The IP...

Страница 164: ...45 1 5 fibre channel D 2 fibre channel troubleshooting 4 7 SFPs 4 7 troubleshooting 4 2 CLI command prompt C 3 defined C 4 help menu illustrated C 4 invoking C 3 logout screen illustrated C 5 main me...

Страница 165: ...d C 14 CLI logout command C 15 CLI logout screen C 5 CLI main menu C 3 CLI netcfg command C 15 CLI ns command C 16 CLI portctl command C 18 CLI portctl cost command C 20 CLI portctl heartbeat command...

Страница 166: ...ter reset view screen 3 27 status panel screen 3 5 switch control tab 3 36 switch health tab 3 32 switch info tab 3 34 system information panel 3 31 system information screen 3 11 task selection toolb...

Страница 167: ...menu 2 10 MSA fabric switch 6 1 2 MSA1000 with a Fabric Switch 6 installed 1 4 network parameters menu 2 6 network tab 3 39 port button screen 3 16 port events tab screen 3 19 port info port control t...

Страница 168: ...ator 1 3 initialization indicator 4 2 main board 1 3 microprocessor 1 3 network parameters menu 2 6 power indicator 4 2 powering up 1 6 prerequisites 1 5 reading indicators 4 2 RS 232 serial interface...

Страница 169: ...venting electrostatic damage to B 1 T tables backup restore tab 3 45 command line interface summary C 1 control buttons 3 8 default serial port settings 2 4 error statistics 3 25 Ethernet indicators 4...

Страница 170: ...tch 6 4 1 preventative maintenance 4 1 serial communication problems 4 6 SFPs 4 7 temperature control problems 4 8 U user interfaces listed 2 2 V versions Switch Management Utility finding E 1 W warni...

Отзывы: