Compaq Pro UPS 500 Скачать руководство пользователя страница 12

Chapter 

2

Installation

This chapter provides information on the following topics:

 

Items Supplied with the UPS Kit.

 

UPS Location Requirements.

 

Connecting the UPS Communications Port.

 

Installing Compaq Power Manager Pro UPS Software.

 

Connecting the UPS Phone/Fax Surge Protector (available on select
models).

 

Verifying a Safe UPS Load.

 

Connecting Devices to the UPS.

 

Circuit Requirements.

 

Connecting the UPS to Utility Power: 120V and 100V Models.

 

Connecting the UPS to Utility Power: 230V Model.

 

Connecting the UPS to an AC Generator.

 

Selecting the UPS Operating Mode.

2-1

Содержание Pro UPS 500

Страница 1: ...Compaq Pro UPS 500 Uninterruptible Power System UPS Operation and Reference Guide First Edition September 1999 Part Number 146293 001 Compaq Computer Corporation...

Страница 2: ...ed Printed in the U S A The software described in this guide is furnished under a license agreement or nondisclosure agreement The software may be used or copied only in accordance with the terms of t...

Страница 3: ...Phone Fax Surge Protector 1 3 Warranties 1 4 25 000 Computer Load Protection Guarantee 1 4 Pre Failure Battery Warranty 1 4 Chapter 2 Installation Items Supplied with the UPS Kit 2 2 Installation Guid...

Страница 4: ...mmendations 3 4 Start On Battery Cold Start Operation 3 5 3 6 Front Panel Controls TEST ALARM RESET Button 3 6 Initiating a UPS Self Test 3 6 3 7 Silencing an Audio Alarm 3 7 3 8 Front Panel Indicator...

Страница 5: ...ng the UPS 6 5 Appendix A Regulatory Compliance Notices Federal Communications Commission Notice A 1 Class B Equipment A 1 A 2 Declaration of Conformity A 2 Modifications A 3 Cables A 3 FCC Part 68 No...

Страница 6: ...ING Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life CAUTION Text set off in this manner indicates that failure to fol...

Страница 7: ...aq com Be sure to have the following information available before you call Compaq Technical support registration number if applicable Product model number s Product model name s and number s Applicabl...

Страница 8: ...Chapter 1 Introduction This chapter provides information on the following topics Compaq Pro UPS 500 Models Compaq Pro UPS 500 Features Warranties 1 1...

Страница 9: ...ut devoting battery power for their support Automatic Voltage Regulation Boost supports connected equipment through periods of low voltage brownouts without using battery power Intelligent communicati...

Страница 10: ...extended utility power blackout the program initiates messaging across the system and starts an operating system shutdown For more information on using the Compaq Power Manager Pro UPS Software see Ch...

Страница 11: ...ply with all instructions and labels The UPS is not damaged by accident other than a utility power transient misuse or abuse Pre Failure Battery Warranty The Pre Failure Battery Warranty standard on a...

Страница 12: ...Installing Compaq Power Manager Pro UPS Software Connecting the UPS Phone Fax Surge Protector available on select models Verifying a Safe UPS Load Connecting Devices to the UPS Circuit Requirements C...

Страница 13: ...on the installation requirements for the Compaq Power Manager Pro UPS software Battery Compaq Pro UPS 500 models are shipped with the battery already installed Power Cords and UPS Computer Interface C...

Страница 14: ...ween 32 F and 104 F between 0 C and 40 C Compaq Pro UPS 500 models are intended for installation in a temperature controlled indoor area free of conductive contamination The unit must be kept dry at a...

Страница 15: ...S 232 cable To avoid damaging the equipment do not use the communications cables supplied with other UPS models IMPORTANT The Compaq Power Manager Pro UPS software requires the communications port to...

Страница 16: ...allows the UPS to protect a communications device from surges on a single phone line Connect a phone cord user supplied from the wall jack to the UPS connector labeled IN Connect a phone cord from yo...

Страница 17: ...UPS Observe the following precautions WARNING Do not use the Compaq Pro UPS 500 for life support applications in which a malfunction or failure of a Compaq Pro UPS 500 could cause failure or signific...

Страница 18: ...S rear panel See Figure 2 3 The Surge Protected Receptacle s will provide connected peripherals with surge protection without committing valuable battery power to support the peripherals during blacko...

Страница 19: ...ng the UPS to Utility Power 120V and 100V Models The 120V and 100V models ship with a non detachable input power cord with a NEMA 5 15 plug Connect the UPS to a grounded utility power outlet After con...

Страница 20: ...rols Connecting the UPS to Utility Power 230V Model The 230V model ships with one IEC 320 jumper power cord After exchanging the UPS IEC 320 jumper cord with your computer power cord connect your comp...

Страница 21: ...e cord The grounding plug is an important safety feature Do not use extension cords IMPORTANT When the UPS is connected to utility power all receptacles will be immediately energized regardless of the...

Страница 22: ...attery is charging Power is ON at the UPS receptacles The green LINE STATUS indicator is flashing The UPS audio alarm is sounding once per minute Setting Advantages Continues to charge the battery whe...

Страница 23: ...formation on the following topics Operation Precautions Front Panel Overview Front Panel Controls ON STANDBY Button Front Panel Controls TEST ALARM RESET Button Front Panel Indicators and Audio Alarms...

Страница 24: ...g the UPS Refer to Initiating a Self test in this chapter for more information Front Panel Overview Compaq Pro UPS 500 models feature the same front panel which includes the controls required to selec...

Страница 25: ...ry charger will be turned OFF Power will be turned OFF at all UPS receptacles and all indicators will be turned OFF Before the UPS can be placed in the IDLE Mode however utility power must be absent a...

Страница 26: ...ownout NOTE The ON STANDBY and IDLE UPS Operating Modes can be manually selected by the user There are however three additional UPS Operating Modes which occur automatically Battery Operate Mode While...

Страница 27: ...s of the internal battery The Surge Protected Receptacles however will not supply AC power until utility power returns To Cold Start the UPS when you first plug in the unit and power is not present mo...

Страница 28: ...on The TEST ALARM RESET button is a momentary switch that allows you to initiate a UPS self test or silence an audio alarm Initiating a UPS Self Test Figure 3 4 Initiating a UPS Self Test In the ON Mo...

Страница 29: ...performed IMPORTANT For the Compaq 500 UPS the only method of checking the battery and circuitry functionality is by performing a UPS self test on a routine basis Silencing an Audio Alarm The UPS may...

Страница 30: ...ower the UPS will return to the mode ON or STANDBY the UPS was in when power was lost ON BATTERY Indicator Yellow Illuminates whenever the UPS is operating from internal batteries After 10 seconds of...

Страница 31: ...ing Remove excess load immediately and initiate a self test to clear the shutdown latch You can detect the presence of an overload by conducting a self test See Initiating a UPS Self Test in this chap...

Страница 32: ...r equipment against damaging surges and line noise Connect your computer monitor and other critical equipment to these receptacles They will provide battery power during blackouts and brownouts only i...

Страница 33: ...ted equipment with AC line power during normal operation They also protect your equipment against damaging surges and line noise Connect your printer and other non critical peripherals to these recept...

Страница 34: ...Chapter 4 Software This chapter provides information on the following topics Software Overview Software Functions Configuration Parameters 4 1...

Страница 35: ...Compaq Power Manager Pro UPS software is year 2000 ready NOTE Compaq NeoServers have UPS software pre installed NeoServer customers do not install this software Software Functions Compaq Power Manage...

Страница 36: ...igure Compaq Power Manager Pro UPS software parameters through the web based interface including Communication setting Poll rate Broadcast settings Wait time before broadcasting message Enable disable...

Страница 37: ...chapter provides information on the following topics Battery Precautions Charging Batteries When to Replace Batteries Pre Failure Battery Warranty Obtaining New Batteries Care and Storage of Batterie...

Страница 38: ...s Set the UPS on a flat level surface and unplug the UPS Use tools with insulated handles and replace the existing batteries with new batteries of the same number and type Do not attempt to recharge b...

Страница 39: ...advantage of a Compaq two year limited warranty by applying warranty coverage to the battery before the battery actually fails Specifically the Pre Failure Battery Warranty ensures that when customer...

Страница 40: ...nded period recharge the batteries every 6 months Connect the UPS to utility power Allow the UPS to charge the batteries for 12 hours Disposing of Used Batteries Replacement equipment includes the ins...

Страница 41: ...Chapter 6 Troubleshooting This chapter provides information on the following topics Troubleshooting During Start Troubleshooting After Start Repairing the UPS 6 1...

Страница 42: ...at the utility power receptacle If desired the UPS can be used as a stand alone power source See Start On Battery Cold Start Operation in Chapter 3 Battery voltage is low because the UPS has been sto...

Страница 43: ...2 seconds until you hear a beep to switch UPS to ON Mode Indicators ON BATTERY BATTERY LOW REPLACE Alarm continuous cannot be silenced Battery voltage is low Automatic shutdown is imminent Immediatel...

Страница 44: ...tinguish Indicators LINE STATUS BATTERY LOW REPLACE Alarm none Battery voltage is low but line power is present and the battery is charging No action is required Indicators LINE STATUS BATTERY LOW REP...

Страница 45: ...Repairing the UPS The UPS has no user serviceable parts All repairs to the UPS including battery replacement must be carried out by Compaq or a Compaq authorized service provider 6 5...

Страница 46: ...hat may reasonably be expected to be installed in a residential environment that is personal computers The FCC requires devices in both classes to bear a label indicating the interference potential of...

Страница 47: ...C logo United States Only This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device mus...

Страница 48: ...the proper operation of your equipment If your Telephone Company does you will be given advance notice to give you an opportunity to maintain uninterrupted service If you experience trouble with this...

Страница 49: ...Commission of the European Community Compliance with these directives implies conformity to the following European Norms the equivalent international standards are in brackets EN55022 CISPR 22 Electr...

Страница 50: ...our UPS contains a Sealed Lead Acid battery pack There is risk of fire and burns if the battery pack is not handled properly To reduce the risk of personal injury Do not attempt to recharge the batter...

Страница 51: ...Appendix B Specifications This appendix provides the following specifications Physical Specifications Input Specifications Output Specifications Battery Specifications Environmental Specifications B 1...

Страница 52: ...able B 2 Input Specifications Per Model UPS Model Nominal Input Voltage Frequency Input Current On Line Voltage Range 500 120V 120VAC 60 Hz 10A 30 to 22 of nominal input voltage 500 100V 100VAC 50 60...

Страница 53: ...e Protected Surge Protected 500 120V 500 300 3 x 5 15R 3 x 5 15R 500 100V 500 300 3 x 5 15R 3 x 5 15R 500 230V 500 300 2 x IEC 320 10A 1 x IEC 320 10A Table B 4 Output Current Specifications Per Model...

Страница 54: ...Surge suppression Up to 6 000V spikes at current levels up to 27 000 A Spike suppression starts at voltages above nominal peak line values Handles up to 240 joules 120V and 100V models or 340 joules...

Страница 55: ...ttery Recharge Rate discharged with 50 load 2 to 4 hours Environmental Specifications Table B 7 Environmental Specifications 120V 100V and 230V models Feature Specification Operating temperature 0o to...

Страница 56: ...1 5 2 A 5 warnings on risk of fire or burns 5 2 A 5 replacement 3 11 5 3 A 5 specifications 5 2 B 5 battery charge indicators See BATTERY LOW REPLACE indicator BATTERY LOW REPLACE indicator overview 3...

Страница 57: ...1 FCC Part 68 Notice A 3 features of the UPS 1 2 Federal Communications Commission FCC notice A 1 front panel controls ON STANDBY Button 3 3 3 4 3 5 3 6 controls TEST ALARM RESET Button 3 6 3 7 indic...

Страница 58: ...lecting a UPS Operating Mode 3 3 3 4 silencing an audio alarm 3 7 start on battery cold start operation 3 5 output specifications B 3 B 4 overload conditions and indicator 3 9 troubleshooting alarm co...

Страница 59: ...ent 3 2 system administrator specifying software parameters 4 3 T Taiwanese Notice A 5 technical support vi telephone numbers vi TEST RESET ALARM Button initiating a self test 3 6 silencing an audio a...

Отзывы: