B-14
AlphaServer 8200/8400 Operations Manual
B.6 How to Update Corrupted Firmware
If LFU identifies a device as unknown, either the firmware on the module is
corrupted or the console does not support or does not recognize the device.
Example B-6 Updating an “Unknown” Device
UPD> display
➊
Name Type Rev Mnemonic
TLSB
0+ KN7CC-AA 8014 0000 kn7cc-aa0
4+ MS7CC 5000 0000 ms7cc0
6+ MS7CC 5000 0000 ms7cc1
8+ KFTHA 2000 0000 kftha0
C0 XMI xmi0
2+ ????? 810 A4A6 unknown0
➋
8+ DWLMA 102A 0003 dwlma0
C+ KDM70 C22 2B01 kdm700
E+ DEMNA C03 0803 demna0
C3 XMI xmi1
1+ DEMFA 823 9120 demfa0
2+ ????? 810 A4A6 unknown1
➋
8+ DWLMA 102A 0104 dwlma1
A+ KCM44 C22 69F1 kcm440
C- ????? FDFF FFFF unknown2
➋
E+ CIXCD C2F 0211 cixcd0
UPD> update unknown*
➌
Confirm update on: unknown2 [Y/(N)]y
WARNING: updates may take several minutes to complete for each device.