System Troubleshooting
6-3
Troubleshooting steps during power-up are described in Figure 6-2.
Figure 6-2 Power-Up Troubleshooting Steps
Check Power and
Console Terminal
Troubleshoot
Failed Module
BX0525-95
Check for air blockage at the top of the cabinet.
Is the SRM and/or graphics console terminal plugged in?
Run the SRM console terminal self-test.
Check the AC circuit breaker indicators.
Check the LEDs on the system power regulators.
Is the SRM console baud rate at 9600?
Reset the system at the control panel.
Does the Fault light continue to blink after 30 seconds?
Call your DIGITAL customer service engineer.
Check the self-test display.
.
Are the power regulator Run lights on? If no:
Is the AC power cord plugged in?
Is the circuit breaker in the On position?
Check the module self-test LED.
If the boot processor failed, reseat the module and then
reset.
1
2
Is the message CPUn:Firmware corruption---update
in progress...Please wait displayed?
Please wait.
Reseat all modules. Make certain modules are fully
inserted.