25
7.3 Power Specification of I/O Expansion Cabinet
Power Spec
U.S./Canada
Japan
Europe
Voltage, Vrms
120
200
220/240
Frequence, Hz
50-60
50-60
50-60
Phase
1
∅
1
∅
1
∅
Power Plug, Quantity
L5-30P, 2
L6-30P, 1
IEC309 3P 32A, 1
Phase current, Arms
22
24
22
Total VA
4,800
4,800
4,800
Total power, watts
4,750
4,750
4,750
Heat output, Btu/hr
16,200
16,200
16,200
7.4 Compaq AlphaServer GS320 Environmental Specifications
Variable
Specifications
Temperature
Operating
5
°
to 35
°
C (41 to 95
°
F)
Non-operating (storage)
-40 to 66
°
C (-40 to 151
°
F)
Relative humidity (non-condensing)
Operating
10 to 90%
Non-operating (storage)
10 to 95%
Maximum altitude
Operating
3050m (10,000ft)
Non-operating (storage)
12,200m (40,000ft)
Minimum Clearances
Front operating
75 cm (29.5 in)
Front Service
75 cm (29.5 in)
Rear Operating
15 cm (6.0 in)
Rear Service
75 cm (29.5 in)
Left side operating
none
Left side service
75 cm (29.5 in)
Right side operating
none
Right side service
none