Compaq Alpha GS320 - надежный и мощный сервер для вашего бизнеса. Получите всю необходимую информацию в информационном руководстве. Скачайте руководство бесплатно с manualshive.com и настройте ваш сервер для оптимальной производительности.
11
3.2 System Cabinet #2, System Box Front Layout (QBB #5, QBB #7)
Figure 6 System Cabinet #2 Quad Building Blocks (QBB #5, QBB #7)
Страница 1: ...1 AlphaServerGS320 Version 1 May 15 2000 Created by the Custom Configuration Documentation Group ...
Страница 2: ...registered trademark in the U S and other countries licensed exclusively through X Open Company Ltd Other product names mentioned herein may be trademarks and or registered trademarks of their respective companies 2000 Compaq Computer Corporation All rights reserved April 1999 Compaq Himalaya NonStop ProLiant ServerNet and Tandem registered U S Patent and Trademark Office Cyclone Enable Enform Env...
Страница 3: ...y DATE DOCUMENT NUMBER REV DESCRIPTION SUMMARY May 15 2000 Preliminary Publication of Document Responsible Department Value added Installation Service Custom Configuration Document Group Responsible Person Thomas Jacob ...
Страница 4: ... 3 Field Replaceable Cables 20 6 0 Compaq AlphaServer Foot Print and Cutout Information 22 6 1 Compaq AlphaServer GS320 22 7 0 Compaq AlphaServer GS320 Environmental Information 23 7 1 Compaq AlphaServer GS320 Physical Information 23 7 2 Compaq AlphaServer GS320 Power Requirements 24 7 3 Power Specification of I O Expansion Cabinet 25 7 4 Compaq AlphaServer GS320 Environmental Specifications 25 8 ...
Страница 5: ...B 4 QBB 6 10 Figure 8 System Cabinet 2 Quad Building Blocks QBB 5 QBB 7 11 Figure 9 Wildfire Operator Control Panel 12 Figure 10 Master PCI Expansion Box 13 Figure 11 Compaq AlphaServer GS320 Powered Subrack 14 Figure 12 Power Supply Installation Order 15 Figure 13 AC Input Box 16 Figure 15 Compaq AlphaServer GS320 Foot Print 22 Tables Table 1 AC Input Box Circuit Breaker Line Protection 16 Table ...
Страница 6: ...ver GS320 System Cabinet Figure 1 Compaq AlphaServer GS320 System Front View Note The picture above depicts a fully configured GS320 with 32 CPUs and 256GB of memory Additional Expander cabinets may be added to increase I O ...
Страница 7: ...7 1 0 Compaq AlphaServer GS320 system continued Figure 2 Compaq AlphaServer 320 System Rear View ...
Страница 8: ...8 2 0 System Cabinet 1 Layout 2 1 System Cabinet 1 System Box Rear Layout QBB 0 QBB 2 Figure 3 System Cabinet 1 Quad Building Blocks QBB 0 QBB 2 ...
Страница 9: ...9 2 2 System Cabinet 1 System Box Front Layout QBB 1 QBB 3 Figure 4 System Cabinet 1 Quad Building Blocks QBB 1 QBB 3 ...
Страница 10: ...10 3 0 System Cabinet 2 Layout 3 1 System Cabinet 2 System Box Rear Layout QBB 4 QBB 6 Figure 5 System Cabinet 2 Quad Building Blocks QBB 4 QBB 6 ...
Страница 11: ...11 3 2 System Cabinet 2 System Box Front Layout QBB 5 QBB 7 Figure 6 System Cabinet 2 Quad Building Blocks QBB 5 QBB 7 ...
Страница 12: ...or Control Panel Figure 7 Wildfire Operator Control Panel The control panel is located at the top of the power cabinet Shown above are the OCP s three position On Off switch three pushbuttons three status LEDs and an ASCII graphical display ...
Страница 13: ...n slots with one inch module pitch all slots except riser 0 slot 5 riser 0 slot 6 riser 1 slot 5 and riser 1 slot 6 Install high performance adapters across multiple bus hose segments to get maximum performance VGA graphics options must be installed in riser 0 slot 2 or riser 0 slot 3 CAUTION Installing a full length module next to the standard I O module requires extra care due to cabling on the ...
Страница 14: ...14 4 3 Compaq AlphaServer GS320 Powered Subrack Figure 9 Compaq AlphaServer GS320 Powered Subrack The power subrack holds three power supplies that power a system box containing two QBBs ...
Страница 15: ...d nuisance tripping of circuit breakers Therefore placement of the third redundant power supply is important Figure 12 provides a chart showing the recommended placement Two power supplies are needed to power one system box the H switch OCP and blower The third power supply is redundant When three power supplies are in a subrack one may be hot swapped ...
Страница 16: ...Boxes are required for the AlphaServer GS320 Table 1 AC Input Box Circuit Breaker Line Protection Circuit Breaker Rating Amps Outlets Protected CB1 30 All CB2 15 J1 CB3 15 J2 CB4 15 J3 CB5 15 J4 CB6 15 J5 CB7 15 J6 CB8 15 J7 J10 CB9 15 J11 J14 CB10 15 J15 J18 CB11 15 J19 J22 ...
Страница 17: ...Qty 4 3X MS8AA DB 54 25070 xx 4 GB GS80 160 320 base memory module 1GB Stacked 200Pin Sync DIMM 100MHz CL2 Qty 4 B4140 xx Directory module DIMM carrier 54 25023 Bx Directory DIMM type 128 Mbit type 2 54 25023 Cx Directory DIMM type 256 Mbit type 3 54 25023 Dx Directory DIMM type 256 Mbit type 4 QBB Modules B4170 xx Local I O riser B4180 BB Global port interface module to hierarchical switch w coax...
Страница 18: ...3R A0284 xx CD ROM RX23L xx 3 5 1 4 MB floppy drive 30 55981 06 SCSI 9 GB disk for factory installed software 54 25027 01 PCI backplane H switch Clock Generation Modules and Distribution Board BA53A xx H switch upgrade 54 25115 01 H switch power system manager HPM 54 30194 01 H switch power converter multi output H7511 30 56061 01 H switch clock module 54 25355 01 H switch CSB interface 54 25371 0...
Страница 19: ...onverter multi output PCI H7507 AA 30 48100 01 1000 watt bulk power converter 48V output H7510 AA 30 48847 01 GS80 U S AC input box H7282 AA 30 48205 04 GS80 European AC input box H7282 AB 30 48205 03 GS80 Japanese AC input box H7282 AC 30 48848 01 GS160 320 U S Japan AC input box H7283 AA 30 48848 02 GS160 320 European AC input box H7283 AB Miscellaneous 70 33559 01 OCP assembly 54 30058 01 Short...
Страница 20: ...1 Power 48V Vaux QBB H switch 17 04716 02 01 long 02 short 17 04722 01 Power 48V Vaux QBB 8 P sys only Dual output clock CSB 17 04736 01 Signal cable CSB node ID mod CSB adapter CSB adapter CSB in H switch or distrib board housing 17 04797 01 Signal cable Standard I O SCSI disk 17 04798 01 Power cable PCI backplane SCSI disk floppy CD ROM 17 04800 01 Signal cable PCI backplane CSB ID module 17 048...
Страница 21: ... Ground strap This cable is used in several locations to electrically ground cabinets QBB backplanes the H switch and distribution board housing 17 05011 01 Signal cable Global ports H switch distribution board 17 05023 01 Ground cable 12 meters System cabinet x Stand alone expander cabinet ...
Страница 22: ...22 6 0 Compaq AlphaServer Foot Print and Cutout Information 6 1 Compaq AlphaServer GS320 Figure 12 Compaq AlphaServer GS320 Foot Print ...
Страница 23: ...h 2000 mm 78 7 in Depth 1000 mm 39 4 in Height 1700 mm 66 9 in Weight 850 kg 1870 lb Expander Cabinet Width 600 mm 23 6 in Depth 1000 mm 39 4 in Height 1700 mm 66 9 in Weight 613 kg 1349 lb Note The GS320 system is comprised of one H9A21 AA and one H9A21 AB cabinet bolted together with a width of 55 The Power cabinet H9A20 BA has a width of 23 5 ...
Страница 24: ...otal VA 1 sys box 4700 1 sys box 4700 1 sys box 4700 2 sys boxes 7050 2 sys boxes 7050 2 sys boxes 7050 3 sys boxes 9850 3 sys boxes 9850 3 sys boxes 9850 4 sys boxes 12 200 4 sys boxes 12 200 4 sys boxes 12 200 Total power watts 1 sys box 4650 1 sys box 4650 1 sys box 4650 2 sys boxes 7000 2 sys boxes 7000 2 sys boxes 7000 3 sys boxes 9750 3 sys boxes 9750 3 sys boxes 9750 4 sys boxes 12 100 4 sy...
Страница 25: ...phaServer GS320 Environmental Specifications Variable Specifications Temperature Operating 5 to 35 C 41 to 95 F Non operating storage 40 to 66 C 40 to 151 F Relative humidity non condensing Operating 10 to 90 Non operating storage 10 to 95 Maximum altitude Operating 3050m 10 000ft Non operating storage 12 200m 40 000ft Minimum Clearances Front operating 75 cm 29 5 in Front Service 75 cm 29 5 in Re...
Страница 26: ...ce percent Vavg Where Vmax maximum line to line RMS voltage Vmin minimum line to line RMS voltage VAB VBC VCA Vavg 3 VAB VBC VCA line to line voltage 8 3 Voltage Transients Power line transients should be no greater in amplitude than the value of the nominal AC RMS voltage This limitation applies to common and transverse mode transients of positive or negative polarity as they are imposed in the A...
Страница 27: ...7 07 mGauss RMS 20 mGauss peak to peak For low resolution monitors the maximum AC magnetic field flux density at power line frequencies varies with the product but is always greater than 7 07 mGauss RMS The maximum DC magnetic field flux density limit up to which most monitors operate properly is approximately 2 0 Gauss For some disk and tape drive products the maximum Dc and AC magnetic field flu...
Страница 28: ...ature range 5o to 50oC 40o to 122oF Temperature rate of change Maximum of 11oC hour 20oF hour Relative humidity range 10 to 95 RH no condensation Wet bulb temperature Maximum of 32oC 90oF 8 14 Altitude Most equipment has been normally tested on a short term basis for performance up to an altitude of 2 4 kilometers 8000 feet Above this altitude the operation of equipment may be impaired 8 15 Airflo...
Страница 29: ...0 320 Installation Guide EK GSR80 IN AlphaServer GS80 Installation Guide AG RKSWA BE AlphaServer GS80 160 320 User Information CD HTML files AG RLVJA BE AlphaServer GS80 160 320 User Information CD translations QA 6GAAB G8 AlphaServer GS80 160 320 Service Documentation Kit EK GS320 SV AlphaServer GS80 160 320 Service Manual AG RKSZA BE AlphaServer GS80 160 320 Service Information CD EK GS320 UP Al...