6.4.3 Port Status
This page provides VLAN Port Status
Label
Description
VLAN User
Various internal software modules may use VLAN services to configure VLAN
port configuration on the fly.
The drop-down list on the right allows for selecting between showing VLAN
memberships as configured by an administrator (Admin) or as configured by
one of these internal software modules.
The “Combined” entry will show a combination of the administrator and
internal software modules configuration, and basically reflects what is actually
configured in hardware.
If a given software modules hasn’t overridden any of the port settings, the text
“No data exists for the selected user” is shown in the table.
Port
The logical port for the settings contained in the same row.
Port Type
Shows the port type (Unaware, C-Port, S-Port,
S-Custom-Port.) that a given user wants to configure on the port.
The field is empty if not overridden by the selected user.
Ingress Filtering
Shows whether a given user wants ingress filtering enabled or not.
The field is empty if not overridden by the selected user.
Frame Type
Shows the acceptable frame types (All, Taged, Untagged) that a given user
wants to configure on the port.
The field is empty if not overridden by the selected user.
Port VLAN ID
Shows the Port VLAN ID (PVID) that a given user wants the
port to have.
The field is empty if not overridden by the selected user.
Tx Tag
Shows the Tx Tag requirements (Tag All, Tag PVID, Tag UVID, Untag All, Untag
PVID, Untag UVID) that a given user has on a port.
The field is empty if not overridden by the selected user.
Untagged VLAN ID
If Tx Tag is overridden by the selected user and is set to Tag or Untag UVID, then
this field will show the VLAN ID the user wants to tag or untag on egress.
The field is empty if not overridden by the selected user.