INS_CNXE2GE2TX8MSPOE 11 Jan 2021 PAGE 53
INSTALLATION AND OPERATION MANUAL
CNXE2GE2TX8MSPOE
TECH SUPPORT: 1.888.678.9427
6.1.9 LLDP
LLDP Configurations
Review and configure current LLDP port settings.
Label
Description
Tx Interval
The switch periodically transmits LLDP frames to its neighbors to update
the network discovery information. The interval between each LLDP frame is
determined by the Tx Interval value which must be between 5 - 32768 seconds.
Tx Hold
Each LLDP frame contains information about how long time the information in the
LLDP frame shall be considered valid. The LLDP information valid period is set to Tx
Hold multiplied by Tx Interval seconds. Valid values must be between 2 - 10 times.
Tx Delay
When a setting is changed (e.g. the IP address), a new LLDP frame is transmitted,
but the time between the LLDP frames will always be at least the value of Tx Delay
seconds. Tx Delay cannot be larger than 1/4 of the Tx Interval value. Valid values
must be between 1 - 8192 seconds.
Tx Reinit
When an interface is disabled, LLDP is disabled or the switch is rebooted, a LLDP
shutdown frame is transmitted to the neighboring units, signaling that the LLDP
information isn’t valid anymore. Tx Reinit controls the amount of seconds between
the shutdown frame and a new LLDP initialization. Valid values must be between
1 - 10 seconds.