MSTP Instance Port interface

Label

Description

Instance

Set the instance’s information except CIST

Port

Selecting the port that you want to configure.

Priority  
(0-240)

Decide which port should be blocked by priority in LAN. Enter a 
number 0 through 240. The value of priority must be the multiple of 16

Path Cost 
(1-200000000)

The cost of the path to the other bridge from this transmitting bridge 
at the specified port. Enter a number 1 through 200000000.

Apply

Select 

Apply

 to activate the configurations.

Содержание CNGE5MS

Страница 1: ...liant unit is a redundant switch offering multiple Ethernet redundancy protocols C Ring ComRing C RSTP and MSTP RSTP STP This redundancy feature protects your applications from network interruptions o...

Страница 2: ...ont Panel 10 Front Panel LEDs 12 Bottom Panel 13 Cables 14 Ethernet Cables 14 10 100 1000BASE T X Pin Assignments 14 SFP 16 Console Cable 17 WEB Management 19 Configuration by Web Browser 19 About Web...

Страница 3: ...ist MAC Filter Table command set 89 Commands Set List SNMP command set 90 Commands Set List Port Mirroring command set 91 Commands Set List 802 1x command set 91 Commands Set List TFTP command set 92...

Страница 4: ...tor This warranty does not cover product modifications or repairs done by persons other than ComNet approved personnel and this warranty does not apply to ComNet products that are misused abused impro...

Страница 5: ...h will work under a wide variety of temperature dirty and humid conditions It can be managed through WEB TELNET Consol or other third party SNMP software The CNGE5MS also can be managed by a utility c...

Страница 6: ...mail SNMP trap and Relay Output Web based Telnet Console CLI configuration Enable disable ports MAC based port security Port based network access control 802 1x VLAN 802 1q to segregate and secure net...

Страница 7: ...Features 3 Redundant DC power inputs Operating Temperature 40 75 C Storage Temperature 40 85 C Operating Humidity 5 95 non condensing Casing IP 30 3 10 100 1000Base T X Gigabit Ethernet port 2 100 10...

Страница 8: ...2 19 13 PAGE 8 INSTALLATION AND OPERATION MANUAL CNGE5MS Tech Support 1 888 678 9427 Installing Switch on DIN Rail The rear panel components of CNGE5MS shown below 1 Screw holes for wall mount kit 2 D...

Страница 9: ...h has a DIN Rail kit on the rear panel The DIN Rail kit affixes the switch to the DIN Rail It is easy to install the switch on the Din Rail Mount Series on DIN Rail Step 1 Tilt the switch and mount th...

Страница 10: ...all mount kit can be found in the package The following steps show how to mount the switch on the wall Mounting the CNGE5MS on a Wall Step 1 Remove DIN Rail kit if it is attached to the switch Step 2...

Страница 11: ...and ports that are on the front of the CNGE5MS Port Description 10 100 1000Base T X RJ 45 fast Ethernet ports 3 10 100 1000Base T X RJ 45 fast Ethernet ports support auto negotiation Default Settings...

Страница 12: ...LED will be light on 4 LED for PWR3 When the PWR3 UP the green LED will be light on 5 LED for R M Ring Master When the LED light is on it means that the switch is the ring master of Ring 6 LED for Rin...

Страница 13: ...activated PWR3 Green On DC Power module 3 activated R M Green On Ring Master Ring Green On Ring enabled Slowly blinking Ring has only One link lack of one link to build the ring Fault Amber On Fault...

Страница 14: ...ON MANUAL CNGE5MS Tech Support 1 888 678 9427 Bottom Panel The bottom panel of CNGE5MS is displayed as below CNGE5MS Rear Panel 1 Terminal block includes PWR1 PWR2 12 48V DC and Relay output 1A 24VDC...

Страница 15: ...cations Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 UTP 100m 328ft RJ 45 100BASE TX Cat 5 100 UTP UTP 100m 328ft RJ 45 1000BASE TX Cat 5 Cat 5e 100 UTP UTP 10...

Страница 16: ...switches support auto MDI MDI X operation You can use a straight through cable to connect PC to switch The following table below shows the 10 100BASE T X MDI and MDI X port pin outs 10 100 Base T MDI...

Страница 17: ...5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Note and signs represent the polarity of the wires that make up each wire pair SFP The Switch has fiber optic ports that utilize SFP connectors...

Страница 18: ...nsole Cable Each CNGE5MS switch can be managed by its console port You can connect them to PC via an RJ 45 cable with DB 9 female connector DB 9 to RJ 45 Cable PC pin out male assignment RS 232 with D...

Страница 19: ...ta Transmitted from DCE Device 3 Transmitted Data Transmitted from DTE Device Received Data Received by DCE Device 4 DTE Ready Transmitted from DTE Device DTE Ready Received by DCE Device 5 Signal Gro...

Страница 20: ...features and allows you to manage the switch from anywhere on the network through a standard web browser such as Microsoft Internet Explorer The Web Based Management function supports Internet Explor...

Страница 21: ...27 System Login 1 Launch your Web Browser 2 Type http and the IP address of the switch Press Enter 3 The login screen appears 4 Enter username and password The default username and password is admin 5...

Страница 22: ...13 PAGE 22 INSTALLATION AND OPERATION MANUAL CNGE5MS Tech Support 1 888 678 9427 Main Interface Main interface Basic Setting System Information The switch system information is provided here System I...

Страница 23: ...tact person or organization Firmware Version Display the switch s firmware version Kernel Version Display the kernel software version MAC Address Display the unique hardware address assigned by manufa...

Страница 24: ...the DHCP client is enabled The current IP will be lost and you should find a new IP address on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is en...

Страница 25: ...the SNTP server UTC Time zone Set the switch location time zone SNTP Server IP Address Set the SNTP server IP address Daylight Saving Time Enable or disable daylight saving time function When dayligh...

Страница 26: ...rs 4 am ADT Alaskan Daylight ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European 1 hour 1 pm FWT French Winter MET Middle European MEWT...

Страница 27: ...allows precise synchronization of networks e g Ethernet Accuracy within the nanosecond range can be achieved with this protocol when using hardware generated timestamps Label Description PTP Client En...

Страница 28: ...ion allows you to update the switch firmware automatically You can put firmware or configuration files on the TFTP server When you reboot the switch it will upgrade automatically Before updating make...

Страница 29: ...r restore the configuration from TFTP server in this page Backup Restore interface The following table describes the labels in this screen Label Description TFTP Server IP Address Fill in the TFTP ser...

Страница 30: ...ON MANUAL CNGE5MS Tech Support 1 888 678 9427 Upgrade Firmware Upgrade Firmware allows you to update the firmware of the switch Before updating make sure you have your TFTP server ready and the firmwa...

Страница 31: ...dress is the beginning of the assigned dynamic IP range For example a dynamic IP assign range is from 192 168 1 100 to 192 168 1 200 192 168 1 100 will be the starting IP address End IP Address The dy...

Страница 32: ...information and display in here DHCP Server Client Entries interface DHCP Server Port and IP bindings You can assign the specific IP address that is in the assigned dynamic IP range to the specific po...

Страница 33: ...le describes the labels in this screen Label Description Port NO Port number for setting Speed Duplex You can set Auto negotiation 1000 full 1000 half 100 full 100 half 10 full 10 half mode Flow Contr...

Страница 34: ...luding broadcast multicast and flooded unicast You can also set Ingress or Egress to limit traffic received or transmitted bandwidth Rate Limit interface The following table describes the labels in th...

Страница 35: ...3ad LACP to combine several physical links with a logical link to increase the bandwidth Port Trunk Setting interface The following table describes the labels in this screen Label Description Group I...

Страница 36: ...Ring technology is a powerful redundant Ring system The recovery time of the Ring is less than 20 milliseconds It can reduce unexpected damage caused by a network topology change C Ring Supports 3 Ri...

Страница 37: ...ide a big ring into two smaller rings to avoid effecting all switches when network topology change It is a good application for connecting two Rings Coupling Port Link to Coupling Port of the switch i...

Страница 38: ...e The switch supports the function and interface for setting the switch as the ring master or not The ring master can negotiate and place command to other switches in the X Ring group If there are 2 o...

Страница 39: ...er vendor s managed switch ComRing interface Label Description Enable Enable the COM Ring function Vendor Select the vendor whose ring you want to join 1st Ring Port Select the port that connects to t...

Страница 40: ...P C RSTP is different from standard STP RSTP the recovery time of C RSTP is less than 20 milliseconds and it supports more connected nodes in a ring topology C RSTP interface The application of C RSTP...

Страница 41: ...anning Tree Protocol It provides faster spanning tree convergence after a topology change The system also supports STP and the system will auto detect the connected device that is running STP or RSTP...

Страница 42: ...of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 Priority 0 240 Decide which port should be blocked by priority in LAN Enter a nu...

Страница 43: ...INS_CNGE5MS_REV 02 19 13 PAGE 43 INSTALLATION AND OPERATION MANUAL CNGE5MS Tech Support 1 888 678 9427 RSTP Information RSTP algorithm results are displayed in this table RSTP Information interface...

Страница 44: ...a standard protocol base on IEEE 802 1s The function is that several VLANs can be mapping to a reduced number of spanning tree instances because most networks do not need more than a few logical topo...

Страница 45: ...the lowest value has the highest priority and is selected as the root If the value changes You must reboot the switch The value must be multiple of 4096 according to the protocol standard rule Max Age...

Страница 46: ...t the specified port Enter a number 1 through 200000000 Admin P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected...

Страница 47: ...le or disable the instance VLANs Set which VLAN will belong which instance Proprietary 0 61440 A value used to identify the root bridge The bridge with the lowest value has the highest priority and is...

Страница 48: ...T Port Selecting the port that you want to configure Priority 0 240 Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16...

Страница 49: ...tion mode is at 802 1Q VLAN Configuration 802 1Q Tagged based VLAN is an IEEE 802 1Q specification standard and it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q...

Страница 50: ...gement Switch Only the devices in the management VLAN can access the switch Link type There are 3 types of link type Access Link single switch only allows you to group ports by setting the same VID Tr...

Страница 51: ...group VLAN port based startup set in the same group of the port can be a normal transmission packet without restricting the types of packets VLAN Configuration Port Base interface 1 The following tabl...

Страница 52: ...N Configuration Port Base interface 2 The following table describes the labels in this screen Label Description Group Name VLAN name VLAN ID Specify the VLAN ID Add Select port to join the VLAN group...

Страница 53: ...c on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receivi...

Страница 54: ...ch Community String is maximum 32 characters Keep empty to remove this Community string SNMPv3User If SNMP V3 agent is selected the SNMPv3 you profiled should be set for authentication The Username is...

Страница 55: ...r by entering the IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version SNMP Trap Setting interfa...

Страница 56: ...ueues will follow 8 4 2 1 ratio to transmit packets from the highest to lowest queue For example 8 high queue packets 4 middle queue packets 2 low queue packets and the one lowest queue packets are tr...

Страница 57: ...Port based priority Port based Priority interface The following table describes the labels in this screen Label Description Port base Priority Assign Port with a priority queue 4 priority queues can b...

Страница 58: ...Service is better known as 802 1p It describes that the output priority of a packet is determined by user priority field in 802 1Q VLAN tag The priority value is supported 0to7 COS value map to 4 pri...

Страница 59: ...DSCP TOS Type of Service is a field in IP header of a packet This TOS field is also used by Differentiated Services and is calLED the Differentiated Services Code Point DSCP The output priority of a p...

Страница 60: ...lity to prune multicast traffic so that it travels only to those end destinations that require that traffic and reduces the amount of traffic on the Ethernet LAN IGMP Snooping interface The following...

Страница 61: ...y forward multicast traffic to the ports that are connected to registered end stations Multicast Filtering interface The following table describes the labels in this screen Label Description IP Addres...

Страница 62: ...can manage the switch through your defined management mode WEB Telnet SNMP IP Security interface The following table describes the labels in this screen Label Description IP security MODE Enable Disa...

Страница 63: ...security is enabled at Port Control page only the frames with MAC addresses in this list will be forwarded otherwise will be discarded Port Security interface The following table describes the labels...

Страница 64: ...in list Any frames forwarding to MAC addresses in this list will be discarded Thus the target device will never receive any frame MAC Blacklist interface The following table describes the labels in t...

Страница 65: ...ver 802 1x makes the use of the physical access characteristics of IEEE802 LAN infrastructures in order to provide an authenticated and authorized devices attached to a LAN port Please refer to IEEE 8...

Страница 66: ...etting Quiet Period Set the time interval between authentication failure and the start of a new authentication attempt Tx Period Set the time that the switch can wait for response to an EAP request id...

Страница 67: ...ls in this screen Label Description Port Authorized Mode Reject force this port to be unauthorized Accept force this port to be authorized Authorize the state of this port was determined by the outcom...

Страница 68: ...rning message will send to your appointed server Email or relay fault to switch panel Fault Alarm When any selected fault event happens the Fault LED in switch panel will light up and the relay will s...

Страница 69: ...smit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting interface The following table describes the labels in this screen Label...

Страница 70: ...ting interface The following table describes the labels in this screen Label Description E mail Alarm Enable Disable transmission system warning events by e mail Sender E mail Address The SMTP server...

Страница 71: ...checkbox cannot be checked when SYSLOG or SMTP is disabled System Warning Event Selection interface The following table describes the labels in this screen Label Description System Event System Cold...

Страница 72: ...supports queries by the Forwarding Process as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port MAC Addres...

Страница 73: ...istics interface The following table describes the labels in this screen Label Description Type Show port speed and media type Link Show port link status State Show ports enable or disable TX GOOD Pac...

Страница 74: ...port as well as sending the frame where it normally would have gone Note that keep all source ports unchecked in order to disable port monitoring Port monitoring interface The following table describe...

Страница 75: ...em Event Log If system log client is enabled the system event logs will show in this table System event log interface The following table describes the labels in this screen Label Description Page Sel...

Страница 76: ...lost when power off or system reset System Configuration interface The following table describes the labels in this screen Label Description Save Save all configurations Help Show help file Factory D...

Страница 77: ...supports CLI management You can use console or telnet to manage the switch by CLI CLI Management by RS 232 Serial Console 9600 8 none 1 none Before configuring by RS 232 serial console use an RJ45 to...

Страница 78: ...INS_CNGE5MS_REV 02 19 13 PAGE 78 INSTALLATION AND OPERATION MANUAL CNGE5MS Tech Support 1 888 678 9427 Step 2 Input a name for new connection Step 3 Select the COM port number...

Страница 79: ...427 Step 4 The COM port properties setting 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appear Use the keyb...

Страница 80: ...ss 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the s...

Страница 81: ...configuration Enter the configure command while in privileged EXEC mode switch config To exit to privileged EXEC mode enter exit or end Use this mode to configure parameters that apply to your Switch...

Страница 82: ...s Subnet mask Gateway G Configure the IP address of switch switch config ip address 192 168 1 1 255 255 255 0 192 168 1 254 ip dhcp G Enable DHCP client function of switch switch config ip dhcp show i...

Страница 83: ...Show client entries of DHCP server switch show dhcpserver clinets show dhcpserver ip binding P Show IP Binding information of DHCP server switch show dhcpserver ip binding no dhcpserver G Disable DHCP...

Страница 84: ...Enable security of interface switch config interface fastEthernet 2 switch config if security enable no security I Disable security of interface switch config interface fastEthernet 2 switch config if...

Страница 85: ...ify the state mode of operation for Ethernet ports Use the disable form of this command to disable the port switch config interface fastEthernet 2 switch config if state Disable show interface configu...

Страница 86: ...ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4 lacp workp 2 or switch config aggrega...

Страница 87: ...6 99 or switch VLAN VLAN 8021q port 3 trunk link tag 3 20 VLAN 8021q port PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by port if the port belong to a t...

Страница 88: ...h config spanning tree hello time 3 spanning tree forward time seconds G Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree inst...

Страница 89: ...ands Set List QoS command set CNGE5MS Commands Level Description Example qos policy weighted fair strict G Select QOS policy scheduling switch config qos policy weighted fair qos prioritytype port bas...

Страница 90: ...atic hwaddr MAC I Configure MAC address table of interface static switch config interface fastEthernet 2 switch config if mac address table static hwaddr 000012345678 mac address table filter hwaddr M...

Страница 91: ...rings public right RO or switch config snmp community strings public right RW snmp snmpv3 user User Name password Authentication Password Privacy Password G Configure the user profile for SNMPV3 agent...

Страница 92: ...CNGE5MS Commands Level Description Example 8021x enable G Enable 802 1x protocols switch config 8021x enable 8021x system radius ip IP address G Change the radius server IP switch config 8021x system...

Страница 93: ...mage switch config backup flash backup_cfg restore flash restore_cfg G Get configuration from TFTP server and need to specify the IP of TFTP server and the file name of image switch config restore fla...

Страница 94: ...Set s ring topology changed event type switch config event ring topology change both event systemlog Link UP Link Down Both I Set port event for system log switch config interface fastethernet 3 swit...

Страница 95: ...sntp daylight period 20060101 01 01 20060202 01 01 sntp daylight offset Minute G Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp dayli...

Страница 96: ...Port G Configure 1st 2nd Ring Port switch config Ring ring port 7 8 Ring coupling port Coupling Port G Configure Coupling Port switch config Ring coupling port 1 Ring control port Control Port G Confi...

Страница 97: ...tion IEEE 802 1AB for LLDP Link Layer Discovery Protocol MAC addresses 8192 Priority Queues 4 Flow Control IEEE 802 3x Flow Control and Back pressure Processing Store and Forward Interface Gigabit Com...

Страница 98: ...54 1 106 1 145 4mm 2 13 4 18 5 72in Casing IP 30 protection Regulatory Approvals EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6...

Страница 99: ...INS_CNGE5MS_REV 02 19 13 PAGE 99 INSTALLATION AND OPERATION MANUAL CNGE5MS Tech Support 1 888 678 9427...

Страница 100: ...ch Support 1 888 678 9427 info comnet net 8 Turnberry Park Road Gildersome Morley Leeds UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 info Europe comnet net MECHANICAL INSTALLATION INSTRUCTIONS...