Cabling
Use four twisted-pair, Category 5e or above cabling for RJ45 port connection. The
cable between the switch and the link partner (switch, hub, workstation, etc.) must be
less than 100 meters (328 ft.) long.
Fiber segment using a small form-factor pluggable, a
single-mode
connector can be
applied to standard (such as 9/125
µ
m, 9.5/125
µ
m, or 10/125
µ
m) single-mode fiber
cable. Fiber spans are dependent on SFP used.
Fiber segment using a small form-factor pluggable, a
multi-mode
connector can be
applied to standard (such as 50 or 62.5/125
µ
m) multi-mode fiber cable. User can
connect two devices up to
2km
distances.
To connect the transceiver and LC cable, please follow the steps shown below:
First, insert the transceiver into the SFP module. Notice that the triangle mark is the bottom
of the module.
Transceiver to the SFP module