INS_CNFE3DOE2/M
10/11/11 PAGE 44
INSTALLATION AND OPERATION MANUAL
CNFE3DOE2/M
TECH SUPPORT: 1.888.678.9427
Upgrading Firmware
There are four files used to upgrade firmware on the terminal server.
IPSetup
Discovers terminal server on the local network and configures its IP
Address.
Autoupdate
Loads the application using UDP.
ModuleUpdate
Batch file that invokes IPSetup & Autoupdate to configure terminal
server with IP address 192.168.10.1 and loads application.
D1381_APP.s19
Application In s-record format.
Module Update
»
Setup a local area network with laptop and module (terminal server) on the 192.168.10.0/24
subnet.
»
Install ModuleUpdate, IPSetup, Autoupdate & d1381_APP.s19 in same directory.
»
Run ModuleUpdate batch file from command prompt where files reside.
»
Program will prompt “Connect Module to the network Press any to continue . . .”
»
Press any key, program will configure module with:
IP address: “192.168.10.1”
Subnet Mask: “255.255.255.0”
Gateway: “192.168.10.254”
Flash: d1381_APP.s19
Figure 47 Terminal Server Upgrade Firmware Director