background image

IN2SMS[POE](C,U)_REV–   10/27/11   PAGE 6

INSTALLATION AND OPERATION MANUAL 

CLFE4+2SMS[POE](C,U) SERIES

 Mixed PoE and Non-PoE systems can be implemented.

 Lower data rates generally provide longer operating distances.

Application notes

INSTALLATION AND OPERATION MANUAL 

CLFE4+2SMS[POE](C,U) SERIES

TECH SUPPORT: 1.888.678.9427

Figure 6 – Application Diagram Without Multicast Traffic

IGMP Disabled, Uplink disabled on the units.

CL1

PC Connections 
on Ports P1-P4

CLFE4+2SMS(C,U)

CLFE4+2SMS(C,U)

CLFE4+2SMS(C,U)

CL1

CL1

CL2

Figure 4 – Typical Application

Figure 5 – Application Diagram With Multicast Traffic

IGMP Enabled, Uplink enabled on the units

CL1

PoE Camera  
Connections 
on Ports P1-P4

CNGE3FE7MS2

CNGE3FE7MS2

CLFE4+2SMS(C,U)

CLFE4+2SMSPOE(C,U)

CLFE4+2SMS(C,U)

CL1

CL1

CL2

Up-layer Network

CL(X)-SFP

CL(X)-SFP

CL(X)-SFP

CL(X)-SFP

Up-layer Network

CLFE4+2SMSC

6   5

1

2

3

4

CLFE4+2SMSPOEC

6

5

1

2

3

4

12VDC

CLFE1EOC

E

E

E

E

E

E

E

E

E

PoE

PoE Devices

Power

Power

Power

Coax/UTP

Legend

CAT5e/6 Cable

PoE Power

Содержание CLFE4+2SMS Series

Страница 1: ...erLine extension port into a further CopperLine extension port that forwards this data to the next CopperLine network device There is no programming required to use this product The ComNet CLFE4 2SMS C U comes pre programmed preventing network video flooding with DIP switch selection of the first CopperLine port as an uplink or as an unmanaged switch Ports 1 4 of the CLFE4 2SMSPOE C U can supply u...

Страница 2: ... 45 Port and Link Activity L A Indicating LED See Installation Instructions Step 4 See Table 3 Indicating LEDs 4 Channel 2 Extended Distance over UTP RJ 45 Port and Link Activity L A Indicating LED See Installation Instructions Step 4 See Table 3 Indicating LEDs 5 Channel 1 Extended Distance over UTP Port DIP Switches for Local Remote Operation Data Speed and Wire Pairs See Installation Instructio...

Страница 3: ...Activity L A Indicating LED See Installation Instructions Step 4 See Table 3 Indicating LEDs 4 Channel 2 Extended Distance over UTP RJ 45 Port and Link Activity L A Indicating LED See Installation Instructions Step 4 See Table 3 Indicating LEDs 5 Channel 1 Extended Distance over UTP Port DIP Switches for Local Remote Operation Data Speed and Wire Pairs See Installation Instructions Steps 1 3 6 Cha...

Страница 4: ... devices 4 SET CL1 UP LINK ENABLED DIP SWITCH Set the Up Link switch to the ON position to enable Uplink port features 5 CONNECT EXTENDED WIRING Connect Extended Distance Port to field wiring 6 CONNECT NETWORK WIRING Using Cat5 5e connect Local unit to network and Remote unit to camera 7 CONNECT POWER Connect power to unit per the following table NOTE Remove Electrical Connector for Rack Mount Uni...

Страница 5: ...d Distance Port Verify that there is no additional equipment e g surge protector on the Extended Link The cable should be continuous from end to end with no active components Table 4 Approximate Maximum Extended Distances Media COAX RG59 U UTP 1 pair UTP 4 pair Extended Port Data Rate 10M 100M 10M 100M 10M 100M Extended Distance1 5 000 ft 1 524 m 2 000 ft 610 m 3 000 ft 914 m 1 000 ft 305 m 3 000 ...

Страница 6: ...Uplink disabled on the units CL1 PC Connections on Ports P1 P4 CLFE4 2SMS C U CLFE4 2SMS C U CLFE4 2SMS C U CL1 CL1 CL2 Figure 4 Typical Application Figure 5 Application Diagram With Multicast Traffic IGMP Enabled Uplink enabled on the units CL1 PoE Camera Connections on Ports P1 P4 CNGE3FE7MS2 CNGE3FE7MS2 CLFE4 2SMS C U CLFE4 2SMSPOE C U CLFE4 2SMS C U CL1 CL1 CL2 Up layer Network CL X SFP CL X S...

Страница 7: ...temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromis...

Отзывы: