4. Functional Description
Page 40
MF0121ACP
_uc.docx
Manual for Node AM4
4.3.3. Dummy Card
figure 4-6 Dummy card
Note:
All unused slots need to be assembled with a dummy card for sufficient
airflow and provided IP class.
Note:
Empty slots of the Node AM will generate an alarm.
Note:
Do not install the dummy card into slot 1.
Note:
Depending on type of fan unit (bottom or backside) different dummy cards
need to be equipped in empty slots.
4.3.4. Power Supply Unit
The power supply unit is mounted in the interior cabinet of the Node AM4. This device
transforms mains power into predefined DC voltages. When performing maintenance,
ensure that all circuits are voltage-free and that the Node AM4 is disconnected from
mains.
figure 4-7 Power supply (DC/DC type), front and back
In units with a 680 W power supply (AC or DC), observe the RF card limitations specified
in chapter 7.1. With the 780 W DC PSU there are only limitations for a mains voltage
from 24 to 36 Vdc which are also specified in chapter 7.1. To decide which type of PSU
is equipped, look up the HID of the PSU on the
Serial and ID Numbers
page of the SW
(PSU IDs see Spare Parts List in chapter 8) or check the power consumption value on
the type label on top of the Node AM:
PSU Type 680
W
780W
Label: