4. Commissioning
M0200ABA_ION-U_EU_H
_23_23
User’s Manual for ION
®
-U
Page 35
figure 4-15 Mains power connector
figure 4-16 Mains power cable - AC
The Mains cable is part of the delivery. It’s available in two wiring configurations:
Wiring 1
Pin
Name
Color
1
Phase
Black
2
Neutral
White
3
n.c.
n.c
PE
Ground
Green
Wiring 2
Pin
Name
Color
1
Phase
Brown
2
Neutral
Blue
3
n.c.
n.c
PE
Ground
Green/Yellow
table 4-3 AC power cable pinning
For the AC power supply connection, a minimum cross section of 1.5
mm
2
is required. Each wire must observe the applicable national
regulations regarding loop impedance, voltage drop, and methods of
installation. Make sure to connect the correct voltage to the unit.
F
Note:
Do not connect or disconnect the power cord at the mains connector while
power is on. Turn off mains* power before connecting the power cord at
the Extension Unit, then, engage mains again.
* Mains power must be interrupted with an external mains breaker. For the mains breaker, observe
the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the
external AC breaker should be 20 Amps max. for 120-Volt service or 13 - 16 Amps for 240-Volt
service.
Pin PE
Pin1
Pin2
Pin3
Protective Cap