![CommScope ION-U EU H 23/23 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/commscope/ion-u-eu-h-23-23/ion-u-eu-h-23-23_user-manual_2643786026.webp)
4. Commissioning
Page 26
M0200ABA_ION-U_EU_H_23_23
User’s Manual for ION
®
-U
ION-U High Power RU Connectors/Indicators
Port/Conn
Purpose
Type
ANT MAIN
This connector is used for transmitting and
receiving either the combined signals from RU
and EU or SISO or MIMO 2300 MHz path 1.
4.3-10 type
female
7-21 IN-
MIMO
This connector is used for combining the signals
from the second EU and the MIMO 2300 MHz
path 2. If not used, the termination on the port
must not be removed.
4.3-10 type
female
EXPANSION
This connector is used to interconnect to the
Remote Unit to provide additional bands of
coverage.
Radiall Opus
M424400-
003
PROBE
MAIN
This connector is used as measurement probe to
antenna port ANT-MAIN.
QMA
PROBE
MIMO
This connector is used as measurement probe to
antenna port ANT-MIMO.
QMA
STATUS
This LED provides a visual warning of an alarm
condition. The color of the LED indicates the
severity of the alarm.
LED
MAINS
This connector provides power to EU models that
use standard AC (100 to 240 Vac) power.
Coninvers
M17 –Series
P20, 4-Pin
EXPANSION
EU
This connector is used to interconnect to the
second Extension Unit to provide additional
bands of coverage.
Radiall Opus
M424400-
003
7-21 IN-
MAIN
This connector is used for combining the signals
from the RU and the MIMO 2300 MHz path 1. If
not used, the termination on the port must not be
removed.
4.3-10 type
female
ANT MIMO
This connector is used for transmitting and
receiving either the combined signals from EU
and EU or SISO or MIMO 2300 MHz path 2.
4.3-10 type
female
Grounding
Bolts
Ground (earth) bolts for connecting the
mandatory ground cable to the EU
M6 bolts,
hex nut, &
washers
table 4-2 ION-U EU H 23/23 connector flange
K
J
I
H
G
F
E
D
C
B
A